Due to a ransomware attack, the wiki was reverted to a July 2022 version. . We apologize for the lack of a more recent valid backup.
...
- 15.1 Apply cell to environment - PASS
- 15.2 Uninstalling Atomix - PASS
- 15.3 Uninstalling ONOS package - PASS
- 15.4 Installing Atomix - PASS
- 15.5 Installing ONOS package - PASS
- 15.6 Set up ONOS secure SSH - PASS
- 15.7 Checking ONOS service - PASS
- 15.8 Starting ONOS CLI sessions - PASS
- 15.9 Checking ONOS nodes - PASS
- 15.10 Checking ONOS applications - PASS
- 15.11 Starting Mininet Topology - PASS
- 15.12 Check whether the flow count is bigger than 28 - PASS
- 15.13 Check whether all flow status are ADDED - PASS
- 15.14 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS
- 15.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE15 - PASS
- 15.16 Stopping Mininet - PASS
- 15.17 Copying karaf logs - PASS
Case 16: Bridging test between two tagged hosts, with dual-homed ToR and 3 ONOS instances -
...
FAIL
- 16.1 Apply cell to environment - PASS
- 16.2 Uninstalling Atomix - PASS
- 16.3 Uninstalling ONOS package - PASS
- 16.4 Installing Atomix - PASS
- 16.5 Installing ONOS package - PASS
- 16.6 Set up ONOS secure SSH - PASS
- 16.7 Checking ONOS service - PASS
- 16.8 Starting ONOS CLI sessions - PASS
- 16.9 Checking ONOS nodes - PASS
- 16.10 Checking ONOS applications - PASS
- 16.11 Starting Mininet Topology - PASS
- 16.12 Check whether the flow count is bigger than 74 - PASS FAIL
- Flow count looks wrong: 6
- 16.13 Check whether all flow status are ADDED - PASS
- 16.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS FAIL
- Flow count looks wrong: 3
- 16.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS FAIL
- Flow count looks wrong: 3
- 16.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE16 - PASS FAIL
- IP connectivity failed
- 16.17 Stopping Mininet - PASS
- 16.18 Copying karaf logs - PASS
...
- 45.1 Apply cell to environment - PASS
- 45.2 Uninstalling Atomix - PASS
- 45.3 Uninstalling ONOS package - PASS
- 45.4 Installing Atomix - PASS
- 45.5 Installing ONOS package - PASS
- 45.6 Set up ONOS secure SSH - PASS
- 45.7 Checking ONOS service - PASS
- 45.8 Starting ONOS CLI sessions - PASS
- 45.9 Checking ONOS nodes - PASS
- 45.10 Checking ONOS applications - PASS
- 45.11 Starting Mininet Topology - PASS
- 45.12 Check whether the flow count is bigger than 28 - PASS
- 45.13 Check whether all flow status are ADDED - PASS
- 45.14 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS
- 45.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE45 - PASS
- 45.16 Stopping Mininet - PASS
- 45.17 Copying karaf logs - PASS
Case 46: Bridging test between untagged host and tagged host, with dual-homed ToR and 3 ONOS instances -
...
PASS
- 46.1 Apply cell to environment - PASS
- 46.2 Uninstalling Atomix - PASS
- 46.3 Uninstalling ONOS package - PASS
- 46.4 Installing Atomix - PASS
- 46.5 Installing ONOS package - PASS
- 46.6 Set up ONOS secure SSH - PASS
- 46.7 Checking ONOS service - PASS
- 46.8 Starting ONOS CLI sessions - PASS
- 46.9 Checking ONOS nodes - PASS
- 46.10 Checking ONOS applications - PASS
- 46.11 Starting Mininet Topology - PASS
- 46.12 Check whether the flow count is bigger than 74 - PASS
- 46.13 Check whether all flow status are ADDED - PASS
- 46.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 46.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 46.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE46 - FAIL IP connectivity failed
- PASS
- 46.17 Stopping Mininet - PASS
- 46.18 Copying karaf logs - PASS
...
- 47.1 Apply cell to environment - PASS
- 47.2 Uninstalling Atomix - PASS
- 47.3 Uninstalling ONOS package - PASS
- 47.4 Installing Atomix - PASS
- 47.5 Installing ONOS package - PASS
- 47.6 Set up ONOS secure SSH - PASS
- 47.7 Checking ONOS service - PASS
- 47.8 Starting ONOS CLI sessions - PASS
- 47.9 Checking ONOS nodes - PASS
- 47.10 Checking ONOS applications - PASS
- 47.11 Starting Mininet Topology - PASS
- 47.12 Check whether the flow count is bigger than 74 - PASS
- 47.13 Check whether all flow status are ADDED - PASS
- 47.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 47.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 47.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE47 - PASS
- 47.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE47 - PASS
- 47.18 Stopping Mininet - PASS
- 47.19 Copying karaf logs - PASS
Case 48: Bridging test between untagged host and tagged host, with 2x4 dual-homed leaf-spine topology and 3 ONOS instances -
...
FAIL
- 48.1 Apply cell to environment - PASS
- 48.2 Uninstalling Atomix - PASS
- 48.3 Uninstalling ONOS package - PASS
- 48.4 Installing Atomix - PASS
- 48.5 Installing ONOS package - PASS
- 48.6 Set up ONOS secure SSH - PASS
- 48.7 Checking ONOS service - PASS
- 48.8 Starting ONOS CLI sessions - PASS
- 48.9 Checking ONOS nodes - PASS
- 48.10 Checking ONOS applications - PASS
- 48.11 Starting Mininet Topology - PASS
- 48.12 Check whether the flow count is bigger than 212 - PASS
- 48.13 Check whether all flow status are ADDED - PASS
- 48.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 48.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 48.16 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS
- 48.17 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS
- 48.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE48 - PASS
- 48.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE48 - PASS FAIL
- IP connectivity failed
- 48.20 Stopping Mininet - PASS
- 48.21 Copying karaf logs - PASS
...