2.2-SR Link Failure with Stratum BMv2 switches
2.2-SR Link Failure with Stratum BMv2 switches
SRLinkFailure at 27 Jan 2021 05:13:12=20
commit f29d97b74268559eb6ab761e2cfd5c3b88782b0f (HEAD -] onos-2.2, origin/o=
nos-2.2)
Author: pierventre [pier@opennetworking.org]
AuthorDate: Fri Jan 8 17:35:47 2021 +0100
Commit: pierventre [pier@opennetworking.org]
CommitDate: Fri Jan 22 18:35:16 2021 +0100
[AETHER-998] FabricPipeliner should support L2 modification of the NextObj=
ective
Case 1: Bridging and Routi=
ng Link Failure test with 2x2 Leaf-spine and 1 Onos - PASS
- 1.1 Constructing test variables - PASS :tick:
- 1.2 Apply cell to environment - PASS :tick:
- 1.3 Uninstalling Atomix - PASS :tick:
- 1.4 Uninstalling ONOS package - PASS :tick:
- 1.5 Building ONOS Docker image - PASS :tick:
- 1.6 Create Cluster Config - PASS :tick:
- 1.7 Installing Atomix via docker containers - PASS :tick:
- 1.8 Installing ONOS via docker containers - PASS :tick:
- 1.9 Set up ONOS secure SSH - PASS :tick:
- 1.10 Starting ONOS CLI sessions - PASS :tick:
- 1.11 Checking ONOS nodes - PASS :tick:
- 1.12 Checking ONOS applications - PASS :tick:
- 1.13 Set logging levels - PASS :tick:
- 1.14 Set ONOS configurations - PASS :tick:
- 1.15 Starting Mininet Topology - PASS :tick:
- 1.16 Configure switches in ONOS - PASS :tick:
- 1.17 Check number of topology elements - PASS :tick:
- 1.18 Check whether the flow count is >=3D 116 - PASS :tick:
- 1.19 Check whether all flow status are ADDED - PASS :tick:
- 1.20 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag=
CASE1 - PASS :tick:
- 1.21 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1 -=
PASS :tick:
- 1.22 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1 - P=
ASS :tick:
- 1.23 Kill link between spine101 and leaf2 - PASS :tick:
- 1.24 Checking topology after link down - PASS :tick:
- 1.25 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag=
CASE1_Failure - PASS :tick:
- 1.26 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_F=
ailure - PASS :tick:
- 1.27 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_Fai=
lure - PASS :tick:
- 1.28 Restore link between spine101 and leaf2 - PASS :tick:
- 1.29 Check whether the flow count is >=3D 116 - PASS :tick:
- 1.30 Check whether all flow status are ADDED - PASS :tick:
- 1.31 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag=
CASE1_Recovery - PASS :tick:
- 1.32 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_R=
ecovery - PASS :tick:
- 1.33 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_Rec=
overy - PASS :tick:
- 1.34 Check number of topology elements - PASS :tick:
- 1.35 Stopping Mininet - PASS :tick:
- 1.36 Copying karaf logs - PASS :tick:
Case 2: Bridging and Routi=
ng Link Failure test with 4x4 Leaf-spine and 1 Onos - FAIL
- 2.1 Apply cell to environment - PASS :tick:
- 2.2 Uninstalling Atomix - PASS :tick:
- 2.3 Uninstalling ONOS package - PASS :tick:
- 2.4 Building ONOS Docker image - PASS :tick:
- 2.5 Create Cluster Config - PASS :tick:
- 2.6 Installing Atomix via docker containers - PASS :tick:
- 2.7 Installing ONOS via docker containers - PASS :tick:
- 2.8 Set up ONOS secure SSH - PASS :tick:
- 2.9 Starting ONOS CLI sessions - PASS :tick:
- 2.10 Checking ONOS nodes - PASS :tick:
- 2.11 Checking ONOS applications - PASS :tick:
- 2.12 Set logging levels - PASS :tick:
- 2.13 Set ONOS configurations - PASS :tick:
- 2.14 Starting Mininet Topology - PASS :tick:
- 2.15 Configure switches in ONOS - PASS :tick:
- 2.16 Check number of topology elements - FAIL :cross:
- Unexpected number of links, switches, and/or controllers: The number of=
links, switches, nodes, and SCCs does not match what was expected
- ONOS sees 8 devices (8 expected) and 24 links (32 expected) and 1 contr=
ollers (1 expected) and 3 SCCs (1 expected)
- 2.17 Check whether the flow count is >=3D 350 - PASS :tick:
- 2.18 Check whether all flow status are ADDED - PASS :tick:
- 2.19 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u=
'h6', u'h7', u'h8'] with tag CASE2 - FAIL :cross:
- 2.20 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2 -=
PASS :tick:
- 2.21 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2 - P=
ASS :tick:
- 2.22 Kill link between spine101 and leaf2 - PASS :tick:
- 2.23 Checking topology after link down - FAIL :cross:
- Topology after link down is incorrect
- 2.24 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u=
'h6', u'h7', u'h8'] with tag CASE2_Failure - FAIL :cross:
- 2.25 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2_F=
ailure - PASS :tick:
- 2.26 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2_Fai=
lure - PASS :tick:
- 2.27 Restore link between spine101 and leaf2 - FAIL :cross:
- 2.28 Check whether the flow count is >=3D 350 - PASS :tick:
- 2.29 Check whether all flow status are ADDED - PASS :tick:
- 2.30 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u=
'h6', u'h7', u'h8'] with tag CASE2_Recovery - FAIL :cross:
- 2.31 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2_R=
ecovery - PASS :tick:
- 2.32 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2_Rec=
overy - PASS :tick:
- 2.33 Check number of topology elements - FAIL :cross:
- Unexpected number of links, switches, and/or controllers: The number of=
links, switches, nodes, and SCCs does not match what was expected
- ONOS sees 8 devices (8 expected) and 24 links (32 expected) and 1 contr=
ollers (1 expected) and 3 SCCs (1 expected)
- 2.34 Stopping Mininet - PASS :tick:
- 2.35 Copying karaf logs - PASS :tick:
Case 4: Bridging and Routi=
ng Link Failure test with 2x2 Leaf-spine and 3 Onos - FAIL
- 4.1 Apply cell to environment - PASS :tick:
- 4.2 Uninstalling Atomix - PASS :tick:
- 4.3 Uninstalling ONOS package - PASS :tick:
- 4.4 Building ONOS Docker image - PASS :tick:
- 4.5 Create Cluster Config - PASS :tick:
- 4.6 Installing Atomix via docker containers - PASS :tick:
- 4.7 Installing ONOS via docker containers - PASS :tick:
- 4.8 Set up ONOS secure SSH - PASS :tick:
- 4.9 Starting ONOS CLI sessions - PASS :tick:
- 4.10 Checking ONOS nodes - PASS :tick:
- 4.11 Checking ONOS applications - PASS :tick:
- 4.12 Set logging levels - PASS :tick:
- 4.13 Set ONOS configurations - PASS :tick:
- 4.14 Starting Mininet Topology - PASS :tick:
- 4.15 Configure switches in ONOS - PASS :tick:
- 4.16 Check number of topology elements - PASS :tick:
- 4.17 Check whether the flow count is >=3D 116 - PASS :tick:
- 4.18 Check whether all flow status are ADDED - PASS :tick:
- 4.19 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag=
CASE3 - FAIL :cross:
- 4.20 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE3 -=
PASS :tick:
- 4.21 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE3 - P=
ASS :tick:
- 4.22 Kill link between spine101 and leaf2 - PASS :tick:
- 4.23 Checking topology after link down - PASS :tick:
- 4.24 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag=
CASE3_Failure - FAIL :cross:
- 4.25 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE3_F=
ailure - PASS :tick:
- 4.26 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE3_Fai=
lure - PASS :tick:
- 4.27 Restore link between spine101 and leaf2 - PASS :tick:
- 4.28 Check whether the flow count is >=3D 116 - PASS :tick:
- 4.29 Check whether all flow status are ADDED - PASS :tick:
- 4.30 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag=
CASE3_Recovery - FAIL :cross:
- 4.31 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE3_R=
ecovery - PASS :tick:
- 4.32 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE3_Rec=
overy - PASS :tick:
- 4.33 Check number of topology elements - PASS :tick:
- 4.34 Stopping Mininet - PASS :tick:
- 4.35 Copying karaf logs - PASS :tick:
Case 5: Bridging and Routi=
ng Link Failure test with 4x4 Leaf-spine and 3 Onos - FAIL
- 5.1 Apply cell to environment - PASS :tick:
- 5.2 Uninstalling Atomix - PASS :tick:
- 5.3 Uninstalling ONOS package - PASS :tick:
- 5.4 Building ONOS Docker image - PASS :tick:
- 5.5 Create Cluster Config - PASS :tick:
- 5.6 Installing Atomix via docker containers - PASS :tick:
- 5.7 Installing ONOS via docker containers - PASS :tick:
- 5.8 Set up ONOS secure SSH - PASS :tick:
- 5.9 Starting ONOS CLI sessions - PASS :tick:
- 5.10 Checking ONOS nodes - PASS :tick:
- 5.11 Checking ONOS applications - PASS :tick:
- 5.12 Set logging levels - PASS :tick:
- 5.13 Set ONOS configurations - PASS :tick:
- 5.14 Starting Mininet Topology - PASS :tick:
- 5.15 Configure switches in ONOS - PASS :tick:
- 5.16 Check number of topology elements - FAIL :cross:
- Unexpected number of links, switches, and/or controllers: The number of=
links, switches, nodes, and SCCs does not match what was expected
- ONOS sees 8 devices (8 expected) and 8 links (32 expected) and 3 contro=
llers (3 expected) and 8 SCCs (1 expected)
- 5.17 Check whether the flow count is >=3D 350 - PASS :tick:
- 5.18 Check whether all flow status are ADDED - PASS :tick:
- 5.19 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u=
'h6', u'h7', u'h8'] with tag CASE4 - FAIL :cross:
- 5.20 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE4 -=
PASS :tick:
- 5.21 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE4 - P=
ASS :tick:
- 5.22 Kill link between spine101 and leaf2 - PASS :tick:
- 5.23 Checking topology after link down - FAIL :cross:
- Topology after link down is incorrect
- 5.24 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u=
'h6', u'h7', u'h8'] with tag CASE4_Failure - FAIL :cross:
- 5.25 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE4_F=
ailure - PASS :tick:
- 5.26 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE4_Fai=
lure - PASS :tick:
- 5.27 Restore link between spine101 and leaf2 - FAIL :cross:
- 5.28 Check whether the flow count is >=3D 350 - PASS :tick:
- 5.29 Check whether all flow status are ADDED - PASS :tick:
- 5.30 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u=
'h6', u'h7', u'h8'] with tag CASE4_Recovery - FAIL :cross:
- 5.31 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE4_R=
ecovery - PASS :tick:
- 5.32 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE4_Rec=
overy - PASS :tick:
- 5.33 Check number of topology elements - FAIL :cross:
- Unexpected number of links, switches, and/or controllers: The number of=
links, switches, nodes, and SCCs does not match what was expected
- ONOS sees 8 devices (8 expected) and 8 links (32 expected) and 3 contro=
llers (3 expected) and 8 SCCs (1 expected)
- 5.34 Stopping Mininet - PASS :tick:
- 5.35 Copying karaf logs - PASS :tick: