Due to a ransomware attack, the wiki was reverted to a July 2022 version. . We apologize for the lack of a more recent valid backup.
...
- 26.1 Apply cell to environment - PASS
- 26.2 Uninstalling Atomix - PASS
- 26.3 Uninstalling ONOS package - PASS
- 26.4 Installing Atomix - PASS
- 26.5 Installing ONOS package - PASS
- 26.6 Set up ONOS secure SSH - PASS
- 26.7 Checking ONOS service - PASS
- 26.8 Starting ONOS CLI sessions - PASS
- 26.9 Checking ONOS nodes - PASS
- 26.10 Checking ONOS applications - PASS
- 26.11 Starting Mininet Topology - PASS
- 26.12 Check whether the flow count is bigger than 74 - PASS
- 26.13 Check whether all flow status are ADDED - PASS
- 26.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 26.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 26.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE26 - PASS
- 26.17 Stopping Mininet - PASS
- 26.18 Copying karaf logs - PASS
Case 27: Bridging test between two untagged hosts on vlan-native port, with 2x2 leaf-spine topology and 3 ONOS instances -
...
FAIL
- 27.1 Apply cell to environment - PASS
- 27.2 Uninstalling Atomix - PASS
- 27.3 Uninstalling ONOS package - PASS
- 27.4 Installing Atomix - PASS
- 27.5 Installing ONOS package - PASS
- 27.6 Set up ONOS secure SSH - PASS
- 27.7 Checking ONOS service - PASS
- 27.8 Starting ONOS CLI sessions - PASS
- 27.9 Checking ONOS nodes - PASS
- 27.10 Checking ONOS applications - PASS
- 27.11 Starting Mininet Topology - PASS
- 27.12 Check whether the flow count is bigger than 74 - PASS
- 27.13 Check whether all flow status are ADDED - PASS
- 27.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 27.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 27.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE27 - PASS FAIL
- IP connectivity failed
- 27.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE27 - PASS
- 27.18 Stopping Mininet - PASS
- 27.19 Copying karaf logs - PASS
...
- 56.1 Apply cell to environment - PASS
- 56.2 Uninstalling Atomix - PASS
- 56.3 Uninstalling ONOS package - PASS
- 56.4 Installing Atomix - PASS
- 56.5 Installing ONOS package - PASS
- 56.6 Set up ONOS secure SSH - PASS
- 56.7 Checking ONOS service - PASS
- 56.8 Starting ONOS CLI sessions - PASS
- 56.9 Checking ONOS nodes - PASS
- 56.10 Checking ONOS applications - PASS
- 56.11 Starting Mininet Topology - PASS
- 56.12 Check whether the flow count is bigger than 74 - PASS
- 56.13 Check whether all flow status are ADDED - PASS
- 56.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 56.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 56.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE56 - PASS
- 56.17 Stopping Mininet - PASS
- 56.18 Copying karaf logs - PASS
Case 57: Bridging test between two untagged hosts with different vlan id, with 2x2 leaf-spine topology and 3 ONOS instances -
...
PASS
- 57.1 Apply cell to environment - PASS
- 57.2 Uninstalling Atomix - PASS
- 57.3 Uninstalling ONOS package - PASS
- 57.4 Installing Atomix - PASS
- 57.5 Installing ONOS package - PASS
- 57.6 Set up ONOS secure SSH - PASS
- 57.7 Checking ONOS service - PASS
- 57.8 Starting ONOS CLI sessions - PASS
- 57.9 Checking ONOS nodes - PASS
- 57.10 Checking ONOS applications - PASS
- 57.11 Starting Mininet Topology - PASS
- 57.12 Check whether the flow count is bigger than 74 - PASS
- 57.13 Check whether all flow status are ADDED - PASS
- 57.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 57.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - FAIL
- Flow count looks wrong: 19
- PASS
- 57.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE57 - PASS
- 57.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE57 - PASS
- 57.18 Stopping Mininet - PASS
- 57.19 Copying karaf logs - PASS
...
- 67.1 Apply cell to environment - PASS
- 67.2 Uninstalling Atomix - PASS
- 67.3 Uninstalling ONOS package - PASS
- 67.4 Installing Atomix - PASS
- 67.5 Installing ONOS package - PASS
- 67.6 Set up ONOS secure SSH - PASS
- 67.7 Checking ONOS service - PASS
- 67.8 Starting ONOS CLI sessions - PASS
- 67.9 Checking ONOS nodes - PASS
- 67.10 Checking ONOS applications - PASS
- 67.11 Starting Mininet Topology - PASS
- 67.12 Check whether the flow count is bigger than 74 - PASS
- 67.13 Check whether all flow status are ADDED - PASS
- 67.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 67.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 67.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE67 - PASS
- 67.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE67 - PASS
- 67.18 Stopping Mininet - PASS
- 67.19 Copying karaf logs - PASS
Case 68: Bridging test between two tagged hosts with different vlan id, with 2x4 dual-homed leaf-spine topology and 3 ONOS instances -
...
FAIL
- 68.1 Apply cell to environment - PASS
- 68.2 Uninstalling Atomix - PASS
- 68.3 Uninstalling ONOS package - PASS
- 68.4 Installing Atomix - PASS
- 68.5 Installing ONOS package - PASS
- 68.6 Set up ONOS secure SSH - PASS
- 68.7 Checking ONOS service - PASS
- 68.8 Starting ONOS CLI sessions - PASS
- 68.9 Checking ONOS nodes - PASS
- 68.10 Checking ONOS applications - PASS
- 68.11 Starting Mininet Topology - PASS
- 68.12 Check whether the flow count is bigger than 212 - PASS FAIL
- Flow count looks wrong: 108
- 68.13 Check whether all flow status are ADDED - PASS
- 68.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS FAIL
- Flow count looks wrong: 18
- 68.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS FAIL
- Flow count looks wrong: 18
- 68.16 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS FAIL
- Flow count looks wrong: 18
- 68.17 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS FAIL
- Flow count looks wrong: 18
- 68.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE68 - PASS
- 68.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE68 - PASS
- 68.20 Stopping Mininet - PASS
- 68.21 Copying karaf logs - PASS
...