Due to a ransomware attack, the wiki was reverted to a July 2022 version. . We apologize for the lack of a more recent valid backup.
...
commit 5e8f07e1d2597767353f44804d9ea0058c20341d (HEAD -] onos-2.2, origin/onos-2.2)
Author: ONOS Jenkins User [jenkins@onlab.us]
AuthorDate: Wed Jan 29 02:25:41 2020 +0000
Commit: ONOS Jenkins User [jenkins@onlab.us]
CommitDate: Wed Jan 29 02:25:41 2020 +0000
Starting snapshot 2.2.1-SNAPSHOT
Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR and 3 ONOS instances -
...
FAIL
- 5.1 Constructing test variables - PASS
- 5.2 Apply cell to environment - PASS
- 5.3 Uninstalling Atomix - PASS
- 5.4 Uninstalling ONOS package - PASS
- 5.5 Creating ONOS package - PASS
- 5.6 Installing Atomix - PASS
- 5.7 Installing ONOS package - PASS
- 5.8 Set up ONOS secure SSH - PASS
- 5.9 Checking ONOS service - PASS
- 5.10 Starting ONOS CLI sessions - PASS
- 5.11 Checking ONOS nodes - PASS
- 5.12 Checking ONOS applications - PASS
- 5.13 Starting Mininet Topology - PASS
- 5.14 Check whether the flow count is bigger than 28 - PASS
- 5.15 Check whether all flow status are ADDED - PASS
- 5.16 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS
- 5.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE5 - PASS FAIL
- IP connectivity failed
- 5.18 Stopping Mininet - PASS
- 5.19 Copying karaf logs - PASS
...
- 16.1 Apply cell to environment - PASS
- 16.2 Uninstalling Atomix - PASS
- 16.3 Uninstalling ONOS package - PASS
- 16.4 Installing Atomix - PASS
- 16.5 Installing ONOS package - PASS
- 16.6 Set up ONOS secure SSH - PASS
- 16.7 Checking ONOS service - PASS
- 16.8 Starting ONOS CLI sessions - PASS
- 16.9 Checking ONOS nodes - PASS
- 16.10 Checking ONOS applications - PASS
- 16.11 Starting Mininet Topology - PASS
- 16.12 Check whether the flow count is bigger than 74 - PASS
- 16.13 Check whether all flow status are ADDED - PASS
- 16.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 16.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 16.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE16 - PASS
- 16.17 Stopping Mininet - PASS
- 16.18 Copying karaf logs - PASS
Case 17: Bridging test between two tagged hosts, with 2x2 leaf-spine topology and 3 ONOS instances -
...
FAIL
- 17.1 Apply cell to environment - PASS
- 17.2 Uninstalling Atomix - PASS
- 17.3 Uninstalling ONOS package - PASS
- 17.4 Installing Atomix - PASS
- 17.5 Installing ONOS package - PASS
- 17.6 Set up ONOS secure SSH - PASS
- 17.7 Checking ONOS service - PASS
- 17.8 Starting ONOS CLI sessions - PASS
- 17.9 Checking ONOS nodes - PASS
- 17.10 Checking ONOS applications - PASS
- 17.11 Starting Mininet Topology - PASS
- 17.12 Check whether the flow count is bigger than 74 - PASS
- 17.13 Check whether all flow status are ADDED - PASS
- 17.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 17.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 17.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE17 - PASS FAIL
- IP connectivity failed
- 17.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE17 - PASS
- 17.18 Stopping Mininet - PASS
- 17.19 Copying karaf logs - PASS
...
- 28.1 Apply cell to environment - PASS
- 28.2 Uninstalling Atomix - PASS
- 28.3 Uninstalling ONOS package - PASS
- 28.4 Installing Atomix - PASS
- 28.5 Installing ONOS package - PASS
- 28.6 Set up ONOS secure SSH - PASS
- 28.7 Checking ONOS service - PASS
- 28.8 Starting ONOS CLI sessions - PASS
- 28.9 Checking ONOS nodes - PASS
- 28.10 Checking ONOS applications - PASS
- 28.11 Starting Mininet Topology - PASS
- 28.12 Check whether the flow count is bigger than 212 - PASS
- 28.13 Check whether all flow status are ADDED - PASS
- 28.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 28.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 28.16 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS
- 28.17 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS
- 28.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE28 - PASS
- 28.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE28 - PASS
- 28.20 Stopping Mininet - PASS
- 28.21 Copying karaf logs - PASS
Case 35: Bridging test between two untagged hosts, one on vlan-untagged port and the other on vlan-native port, with single ToR and 3 ONOS instances -
...
FAIL
- 35.1 Apply cell to environment - PASS
- 35.2 Uninstalling Atomix - PASS
- 35.3 Uninstalling ONOS package - PASS
- 35.4 Installing Atomix - PASS
- 35.5 Installing ONOS package - PASS
- 35.6 Set up ONOS secure SSH - PASS
- 35.7 Checking ONOS service - PASS
- 35.8 Starting ONOS CLI sessions - PASS
- 35.9 Checking ONOS nodes - PASS
- 35.10 Checking ONOS applications - PASS
- 35.11 Starting Mininet Topology - PASS
- 35.12 Check whether the flow count is bigger than 28 - PASS
- 35.13 Check whether all flow status are ADDED - PASS
- 35.14 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS
- 35.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE35 - PASS FAIL
- IP connectivity failed
- 35.16 Stopping Mininet - PASS
- 35.17 Copying karaf logs - PASS
...
- 46.1 Apply cell to environment - PASS
- 46.2 Uninstalling Atomix - PASS
- 46.3 Uninstalling ONOS package - PASS
- 46.4 Installing Atomix - PASS
- 46.5 Installing ONOS package - PASS
- 46.6 Set up ONOS secure SSH - PASS
- 46.7 Checking ONOS service - PASS
- 46.8 Starting ONOS CLI sessions - PASS
- 46.9 Checking ONOS nodes - PASS
- 46.10 Checking ONOS applications - PASS
- 46.11 Starting Mininet Topology - PASS
- 46.12 Check whether the flow count is bigger than 74 - PASS
- 46.13 Check whether all flow status are ADDED - PASS
- 46.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 46.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 46.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE46 - PASS
- 46.17 Stopping Mininet - PASS
- 46.18 Copying karaf logs - PASS
Case 47: Bridging test between untagged host and tagged host, with 2x2 leaf-spine topology and 3 ONOS instances -
...
PASS
- 47.1 Apply cell to environment - PASS
- 47.2 Uninstalling Atomix - PASS
- 47.3 Uninstalling ONOS package - PASS
- 47.4 Installing Atomix - PASS
- 47.5 Installing ONOS package - PASS
- 47.6 Set up ONOS secure SSH - PASS
- 47.7 Checking ONOS service - PASS
- 47.8 Starting ONOS CLI sessions - PASS
- 47.9 Checking ONOS nodes - PASS
- 47.10 Checking ONOS applications - PASS
- 47.11 Starting Mininet Topology - PASS
- 47.12 Check whether the flow count is bigger than 74 - PASS
- 47.13 Check whether all flow status are ADDED - PASS
- 47.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 47.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - FAIL
- Flow count looks wrong: 19
- PASS
- 47.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE47 - PASS
- 47.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE47 - FAIL IP connectivity failed
- PASS
- 47.18 Stopping Mininet - PASS
- 47.19 Copying karaf logs - PASS
...