commit 07870723b494f66129c5ef28a0e75492a8562ffb (HEAD -] master, origin/master, origin/HEAD)
Author: William Davies [william.davies@infosys.com]
AuthorDate: Tue Jul 23 21:18:53 2019 +0000
Commit: Charles Chan [rascov@gmail.com]
CommitDate: Fri Feb 14 15:55:51 2020 -0800
Adding port validations for Xconnect service creation
Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR and 3 ONOS instances -
...
FAIL
- 5.1 Constructing test variables - PASS
- 5.2 Apply cell to environment - PASS
- 5.3 Uninstalling Atomix - PASS
- 5.4 Uninstalling ONOS package - PASS
- 5.5 Creating ONOS package - PASS
- 5.6 Installing Atomix - PASS
- 5.7 Installing ONOS package - PASS
- 5.8 Set up ONOS secure SSH - PASS
- 5.9 Checking ONOS service - PASS
- 5.10 Starting ONOS CLI sessions - PASS
- 5.11 Checking ONOS nodes - PASS
- 5.12 Checking ONOS applications - PASS
- 5.13 Starting Mininet Topology - PASS
- 5.14 Check whether the flow count is bigger than 28 - PASS
- 5.15 Check whether all flow status are ADDED - PASS
- 5.16 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS
- 5.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE5 - PASS FAIL
- IP connectivity failed
- 5.18 Stopping Mininet - PASS
- 5.19 Copying karaf logs - PASS
...
- 7.1 Apply cell to environment - PASS
- 7.2 Uninstalling Atomix - PASS
- 7.3 Uninstalling ONOS package - PASS
- 7.4 Installing Atomix - PASS
- 7.5 Installing ONOS package - PASS
- 7.6 Set up ONOS secure SSH - PASS
- 7.7 Checking ONOS service - PASS
- 7.8 Starting ONOS CLI sessions - PASS
- 7.9 Checking ONOS nodes - PASS
- 7.10 Checking ONOS applications - PASS
- 7.11 Starting Mininet Topology - PASS
- 7.12 Check whether the flow count is bigger than 74 - PASS
- 7.13 Check whether all flow status are ADDED - PASS
- 7.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 7.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 7.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE7 - PASS
- 7.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE7 - PASS
- 7.18 Stopping Mininet - PASS
- 7.19 Copying karaf logs - PASS
Case 8: Bridging test between two untagged hosts on vlan-untagged port, with 2x4 dual-homed leaf-spine topology and 3 ONOS instances -
...
FAIL
- 8.1 Apply cell to environment - PASS
- 8.2 Uninstalling Atomix - PASS
- 8.3 Uninstalling ONOS package - PASS
- 8.4 Installing Atomix - PASS
- 8.5 Installing ONOS package - PASS
- 8.6 Set up ONOS secure SSH - PASS
- 8.7 Checking ONOS service - PASS
- 8.8 Starting ONOS CLI sessions - PASS
- 8.9 Checking ONOS nodes - PASS
- 8.10 Checking ONOS applications - PASS
- 8.11 Starting Mininet Topology - PASS
- 8.12 Check whether the flow count is bigger than 212 - PASS
- 8.13 Check whether all flow status are ADDED - PASS
- 8.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 8.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 8.16 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS
- 8.17 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS
- 8.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE8 - PASS
- 8.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE8 - PASS FAIL
- IP connectivity failed
- 8.20 Stopping Mininet - PASS
- 8.21 Copying karaf logs - PASS
Case 15: Bridging test between two tagged hosts, with single ToR and 3 ONOS instances -
...
FAIL
- 15.1 Apply cell to environment - PASS
- 15.2 Uninstalling Atomix - PASS
- 15.3 Uninstalling ONOS package - PASS
- 15.4 Installing Atomix - PASS
- 15.5 Installing ONOS package - PASS
- 15.6 Set up ONOS secure SSH - PASS
- 15.7 Checking ONOS service - PASS
- 15.8 Starting ONOS CLI sessions - PASS
- 15.9 Checking ONOS nodes - PASS
- 15.10 Checking ONOS applications - PASS
- 15.11 Starting Mininet Topology - PASS
- 15.12 Check whether the flow count is bigger than 28 - PASS
- 15.13 Check whether all flow status are ADDED - PASS
- 15.14 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS
- 15.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE15 - PASS FAIL
- IP connectivity failed
- 15.16 Stopping Mininet - PASS
- 15.17 Copying karaf logs - PASS
...
- 17.1 Apply cell to environment - PASS
- 17.2 Uninstalling Atomix - PASS
- 17.3 Uninstalling ONOS package - PASS
- 17.4 Installing Atomix - PASS
- 17.5 Installing ONOS package - PASS
- 17.6 Set up ONOS secure SSH - PASS
- 17.7 Checking ONOS service - PASS
- 17.8 Starting ONOS CLI sessions - PASS
- 17.9 Checking ONOS nodes - PASS
- 17.10 Checking ONOS applications - PASS
- 17.11 Starting Mininet Topology - PASS
- 17.12 Check whether the flow count is bigger than 74 - PASS
- 17.13 Check whether all flow status are ADDED - PASS
- 17.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 17.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 17.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE17 - PASS
- 17.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE17 - PASS
- 17.18 Stopping Mininet - PASS
- 17.19 Copying karaf logs - PASS
Case 18: Bridging test between two tagged hosts, with 2x4 dual-homed leaf-spine topology and 3 ONOS instances -
...
FAIL
- 18.1 Apply cell to environment - PASS
- 18.2 Uninstalling Atomix - PASS
- 18.3 Uninstalling ONOS package - PASS
- 18.4 Installing Atomix - PASS
- 18.5 Installing ONOS package - PASS
- 18.6 Set up ONOS secure SSH - PASS
- 18.7 Checking ONOS service - PASS
- 18.8 Starting ONOS CLI sessions - PASS
- 18.9 Checking ONOS nodes - PASS
- 18.10 Checking ONOS applications - PASS
- 18.11 Starting Mininet Topology - PASS
- 18.12 Check whether the flow count is bigger than 212 - PASS FAIL
- Flow count looks wrong: 141
- 18.13 Check whether all flow status are ADDED - PASS
- 18.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS FAIL
- Flow count looks wrong: 17
- 18.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS FAIL
- Flow count looks wrong: 17
- 18.16 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS FAIL
- Flow count looks wrong: 17
- 18.17 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS FAIL
- Flow count looks wrong: 20
- 18.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE18 - PASS FAIL
- IP connectivity failed
- 18.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE18 - PASS FAIL
- IP connectivity failed
- 18.20 Stopping Mininet - PASS
- 18.21 Copying karaf logs - PASS
Case 25: Bridging test between two untagged hosts on vlan-native port, with single ToR and 3 ONOS instances -
...
FAIL
- 25.1 Apply cell to environment - PASS
- 25.2 Uninstalling Atomix - PASS
- 25.3 Uninstalling ONOS package - PASS
- 25.4 Installing Atomix - PASS
- 25.5 Installing ONOS package - PASS
- 25.6 Set up ONOS secure SSH - PASS
- 25.7 Checking ONOS service - PASS
- 25.8 Starting ONOS CLI sessions - PASS
- 25.9 Checking ONOS nodes - PASS
- 25.10 Checking ONOS applications - PASS
- 25.11 Starting Mininet Topology - PASS
- 25.12 Check whether the flow count is bigger than 28 - PASS
- 25.13 Check whether all flow status are ADDED - PASS
- 25.14 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS
- 25.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE25 - PASS FAIL
- IP connectivity failed
- 25.16 Stopping Mininet - PASS
- 25.17 Copying karaf logs - PASS
...
- 26.1 Apply cell to environment - PASS
- 26.2 Uninstalling Atomix - PASS
- 26.3 Uninstalling ONOS package - PASS
- 26.4 Installing Atomix - PASS
- 26.5 Installing ONOS package - PASS
- 26.6 Set up ONOS secure SSH - PASS
- 26.7 Checking ONOS service - PASS
- 26.8 Starting ONOS CLI sessions - PASS
- 26.9 Checking ONOS nodes - PASS
- 26.10 Checking ONOS applications - PASS
- 26.11 Starting Mininet Topology - PASS
- 26.12 Check whether the flow count is bigger than 74 - PASS
- 26.13 Check whether all flow status are ADDED - PASS
- 26.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 26.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 26.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE26 - PASS
- 26.17 Stopping Mininet - PASS
- 26.18 Copying karaf logs - PASS
Case 27: Bridging test between two untagged hosts on vlan-native port, with 2x2 leaf-spine topology and 3 ONOS instances -
...
FAIL
- 27.1 Apply cell to environment - PASS
- 27.2 Uninstalling Atomix - PASS
- 27.3 Uninstalling ONOS package - PASS
- 27.4 Installing Atomix - PASS
- 27.5 Installing ONOS package - PASS
- 27.6 Set up ONOS secure SSH - PASS
- 27.7 Checking ONOS service - PASS
- 27.8 Starting ONOS CLI sessions - PASS
- 27.9 Checking ONOS nodes - PASS
- 27.10 Checking ONOS applications - PASS
- 27.11 Starting Mininet Topology - PASS
- 27.12 Check whether the flow count is bigger than 74 - PASS
- 27.13 Check whether all flow status are ADDED - PASS
- 27.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 27.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 27.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE27 - PASS FAIL
- IP connectivity failed
- 27.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE27 - PASS
- 27.18 Stopping Mininet - PASS
- 27.19 Copying karaf logs - PASS
...
- 28.1 Apply cell to environment - PASS
- 28.2 Uninstalling Atomix - PASS
- 28.3 Uninstalling ONOS package - PASS
- 28.4 Installing Atomix - PASS
- 28.5 Installing ONOS package - PASS
- 28.6 Set up ONOS secure SSH - PASS
- 28.7 Checking ONOS service - PASS
- 28.8 Starting ONOS CLI sessions - PASS
- 28.9 Checking ONOS nodes - PASS
- 28.10 Checking ONOS applications - PASS
- 28.11 Starting Mininet Topology - PASS
- 28.12 Check whether the flow count is bigger than 212 - PASS
- 28.13 Check whether all flow status are ADDED - PASS
- 28.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 28.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 28.16 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS
- 28.17 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS
- 28.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE28 - PASS
- 28.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE28 - PASS
- 28.20 Stopping Mininet - PASS
- 28.21 Copying karaf logs - PASS
Case 35: Bridging test between two untagged hosts, one on vlan-untagged port and the other on vlan-native port, with single ToR and 3 ONOS instances -
...
FAIL
- 35.1 Apply cell to environment - PASS
- 35.2 Uninstalling Atomix - PASS
- 35.3 Uninstalling ONOS package - PASS
- 35.4 Installing Atomix - PASS
- 35.5 Installing ONOS package - PASS
- 35.6 Set up ONOS secure SSH - PASS
- 35.7 Checking ONOS service - PASS
- 35.8 Starting ONOS CLI sessions - PASS
- 35.9 Checking ONOS nodes - PASS
- 35.10 Checking ONOS applications - PASS
- 35.11 Starting Mininet Topology - PASS
- 35.12 Check whether the flow count is bigger than 28 - PASS
- 35.13 Check whether all flow status are ADDED - PASS
- 35.14 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS
- 35.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE35 - PASS FAIL
- IP connectivity failed
- 35.16 Stopping Mininet - PASS
- 35.17 Copying karaf logs - PASS
...
- 47.1 Apply cell to environment - PASS
- 47.2 Uninstalling Atomix - PASS
- 47.3 Uninstalling ONOS package - PASS
- 47.4 Installing Atomix - PASS
- 47.5 Installing ONOS package - PASS
- 47.6 Set up ONOS secure SSH - PASS
- 47.7 Checking ONOS service - PASS
- 47.8 Starting ONOS CLI sessions - PASS
- 47.9 Checking ONOS nodes - PASS
- 47.10 Checking ONOS applications - PASS
- 47.11 Starting Mininet Topology - PASS
- 47.12 Check whether the flow count is bigger than 74 - PASS
- 47.13 Check whether all flow status are ADDED - PASS
- 47.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 47.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 47.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE47 - PASS
- 47.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE47 - PASS
- 47.18 Stopping Mininet - PASS
- 47.19 Copying karaf logs - PASS
Case 48: Bridging test between untagged host and tagged host, with 2x4 dual-homed leaf-spine topology and 3 ONOS instances -
...
PASS
- 48.1 Apply cell to environment - PASS
- 48.2 Uninstalling Atomix - PASS
- 48.3 Uninstalling ONOS package - PASS
- 48.4 Installing Atomix - PASS
- 48.5 Installing ONOS package - PASS
- 48.6 Set up ONOS secure SSH - PASS
- 48.7 Checking ONOS service - PASS
- 48.8 Starting ONOS CLI sessions - PASS
- 48.9 Checking ONOS nodes - PASS
- 48.10 Checking ONOS applications - PASS
- 48.11 Starting Mininet Topology - PASS
- 48.12 Check whether the flow count is bigger than 212 - PASS
- 48.13 Check whether all flow status are ADDED - PASS
- 48.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 48.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 48.16 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS
- 48.17 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS
- 48.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE48 - PASS
- 48.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE48 - FAIL IP connectivity failed
- PASS
- 48.20 Stopping Mininet - PASS
- 48.21 Copying karaf logs - PASS
...