Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Published from Jenkins build: https://onos-jenkins.onlab.us/job/SRLinkFailure/5/

...

  • 1.1 Constructing test variables - PASS (tick)
  • 1.2 Create and Apply cell file - PASS (tick)
  • 1.3 Create and Install ONOS package - PASS (tick)
  • 1.4 Starting ONOS service - PASS (tick)
  • 1.5 Checking if ONOS CLI is ready - PASS (tick)
  • 1.6 Starting Mininet Topology - PASS (tick)
  • 1.7 Check whether the flow count is bigger than 116 - PASS (tick)
  • 1.8 Check whether all flow status are ADDED - PASS (tick)
  • 1.9 Check full IP connectivity - PASS (tick)
  • 1.10 Check VLAN connectivity - PASS (tick)
  • 1.11 Kill link between spine101 and leaf2 - PASS (tick)
  • 1.12 Check IP connectivity CASE1_Failure - PASS (tick)
  • 1.11 13 Check full VLAN connectivity CASE1_Failure - PASS (tick)
  • 1.12 14 Restore link between spine101 and leaf2 - FAIL (error)
    • Failed to bring link up
  • 1.15 Check IP connectivity CASE1_Recovery - PASS (tick)
  • 1.13 16 Check full VLAN connectivity CASE1_Recovery - PASS (tick)

...

  • 2.1 Create and Apply cell file - PASS (tick)
  • 2.2 Create and Install ONOS package - PASS (tick)
  • 2.3 Starting ONOS service - PASS (tick)
  • 2.4 Checking if ONOS CLI is ready - PASS (tick)
  • 2.5 Starting Mininet Topology - PASS (tick)
  • 2.6 Check whether the flow count is bigger than 350 - PASS (tick)
  • 2.7 Check whether all flow status are ADDED - PASS (tick)
  • 2.8 Check full IP connectivity - PASS (tick)
  • 2.9 Check VLAN connectivity - PASS (tick)
  • 2.10 Kill link between spine101 and leaf2 - PASS (tick)
  • 2.11 Check IP connectivity CASE2_Failure - PASS (tick)
  • 2.10 12 Check full VLAN connectivity CASE2_Failure - PASS (tick)
  • 2.11 13 Restore link between spine101 and leaf2 - FAIL (error)
    • Failed to bring link up
  • 2.14 Check IP connectivity CASE2_Recovery - PASS (tick)
  • 2.12 15 Check full VLAN connectivity CASE2_Recovery - PASS (tick)

...

  • 4.1 Create and Apply cell file - PASS (tick)
  • 4.2 Create and Install ONOS package - PASS (tick)
  • 4.3 Starting ONOS service - PASS (tick)
  • 4.4 Checking if ONOS CLI is ready - PASS (tick)
  • 4.5 Starting Mininet Topology - PASS (tick)
  • 4.6 Check whether the flow count is bigger than 116 - PASS (tick)
  • 4.7 Check whether all flow status are ADDED - PASS (tick)
  • 4.8 Check full IP connectivity - PASS (tick)
  • 4.9 Check VLAN connectivity - PASS (tick)
  • 4.10 Kill link between spine101 and leaf2 - PASS (tick)
  • 4.11 Check IP connectivity CASE3_Failure - PASS (tick)
  • 4.10 12 Check full VLAN connectivity CASE3_Failure - PASS (tick)
  • 4.11 13 Restore link between spine101 and leaf2 - FAIL (error)
    • Failed to bring link up
  • 4.14 Check IP connectivity CASE3_Recovery - PASS (tick)
  • 4.15 Check VLAN 12 Check full connectivity CASE3_Recovery - PASS (tick)

...

  • 5.1 Create and Apply cell file - PASS (tick)
  • 5.2 Create and Install ONOS package - PASS (tick)
  • 5.3 Starting ONOS service - PASS (tick)
  • 5.4 Checking if ONOS CLI is ready - PASS (tick)
  • 5.5 Starting Mininet Topology - PASS (tick)
  • 5.6 Check whether the flow count is bigger than 350 - PASS (tick)
  • 5.7 Check whether all flow status are ADDED - PASS (tick)
  • 5.8 Check full IP connectivity - PASS (tick)
  • 5.9 Check VLAN connectivity - PASS (tick)
  • 5.10 Kill link between spine101 and leaf2 - PASS (tick)
  • 5.11 Check IP connectivity CASE2_Failure - PASS (tick)
  • 5.10 12 Check full VLAN connectivity CASE2_Failure - PASS (tick)
  • 5.11 13 Restore link between spine101 and leaf2 - FAIL (error)
    • Failed to bring link up
  • 5.14 Check IP connectivity CASE2_Recovery - PASS (tick)
  • 5.15 Check VLAN 12 Check full connectivity CASE2_Recovery - PASS (tick)