Due to a ransomware attack, the wiki was reverted to a July 2022 version. . We apologize for the lack of a more recent valid backup.
...
- 2.1 Assign switches to controllers - PASS
Case 8: Compare ONOS Topology view to Mininet topology -
...
PASS
Compare topology objects between Mininet and ONOS
- 8.1 Comparing ONOS topology to MN topology - FAIL
- PASS
- 8.2 Hosts view is consistent across all ONOS nodes - PASS
- 8.3 Hosts information is correct - PASS
- 8.4 Host attachment points to the network - PASS
- 8.5 Clusters view is consistent across all ONOS nodes - PASS
- 8.6 There is only one SCC - FAIL
PASS
ONOS shows - 8 SCCs
- 8.7 Device information is correct - PASS
- 8.8 Links are correct - FAIL
- PASS
- 8.9 Hosts are correct - PASS
- 8.10 Checking ONOS nodes - PASS
...
- 21.1 Assign mastership of switches to specific controllers - PASS
- 21.2 Check mastership was correctly assigned - PASS
Case 3: Adding host Intents -
...
PASS
Discover hosts by using pingall then assign predetermined host-to-host intents. After installation, check that the intent is distributed to all nodes and the state is INSTALLED
- 3.1 Install reactive forwarding app - PASS
- 3.2 Check app ids - PASS
- 3.3 Discovering Hosts( Via pingall for now ) - FAIL
- PASS
- 3.4 Uninstall reactive forwarding app - PASS
- 3.5 Check app ids - PASS
- 3.6 Add host intents via cli - PASS
- 3.7 Intent Anti-Entropy dispersion - PASS
Case 8: Compare ONOS Topology view to Mininet topology -
...
PASS
Compare topology objects between Mininet and ONOS
- 8.1 Comparing ONOS topology to MN topology - FAIL
- PASS
- 8.2 Hosts view is consistent across all ONOS nodes - PASS
- 8.3 Hosts information is correct - PASS
- 8.4 Host attachment points to the network - PASS
- 8.5 Clusters view is consistent across all ONOS nodes - PASS
- 8.6 There is only one SCC - FAIL
- ONOS shows 2 SCCs
- PASS
- 8.7 Device information is correct - PASS
- 8.8 Links are correct - FAIL
- PASS
- 8.9 Hosts are correct - PASS
- 8.10 Checking ONOS nodes - PASS
Case 4: Verify connectivity by sending traffic across Intents -
...
PASS
Ping across added host intents to check functionality and check the state of the intent
- 4.1 Check Intent state - PASS
- 4.2 Ping across added host intents - FAIL
- PASS
- 4.3 Check leadership of topics - PASS
- 4.4 Wait a minute then ping again - FAIL
- Intents have not been installed correctly, pings failed.
- PASS
Case 5: Setting up and gathering data for current state -
...
PASS
- 5.1 Check that each switch has a master - PASS
- 5.2 Get the Mastership of each switch from each controller - PASS
- 5.3 Check for consistency in roles from each controller - PASS
- 5.4 Get the intents from each controller - PASS
- 5.5 Check for consistency in Intents from each controller - PASS
- 5.6 Get the flows from each controller - PASS
- 5.7 Check for consistency in Flows from each controller - PASS
- 5.8 Get the OF Table entries - No Result
- 5.9 Start continuous pings - No Result
- 5.10 Collecting topology information from ONOS - No Result
- 5.11 Host view is consistent across ONOS nodes - PASS
- 5.12 Each host has an IP address - PASS
- 5.13 Cluster view is consistent across ONOS nodes - PASS
- 5.14 Cluster view correct across ONOS nodes - FAIL
- ONOS shows 2 SCCs
- PASS
- 5.15 Comparing ONOS topology to MN - PASS
- 5.16 Device information is correct - PASS
- 5.17 Links are correct - FAIL
- PASS
- 5.18 Hosts are correct - PASS
...