Due to a ransomware attack, the wiki was reverted to a July 2022 version. . We apologize for the lack of a more recent valid backup.
...
- 3.1 Create and Apply cell file - PASS
- 3.2 Create and Install ONOS package - PASS
- 3.3 Starting ONOS service - PASS
- 3.4 Checking if ONOS CLI is ready - PASS
- 3.5 Starting Mininet Topology - PASS
- 3.6 Check whether the flow count is bigger than 15 - PASS
- 3.7 Check whether all flow status are ADDED - PASS
- 3.8 Connectivity for [u'h1', u'h2'] CASE3 - PASS
- 3.9 Connectivity for [u'olt10', u'vsg10'] CASE3 - PASS
- 3.10 Connectivity for [u'olt5', u'vsg5'] CASE3 - PASS
Case 4: Bridging and Routing sanity test with 2x2 Leaf-spine -
...
FAIL
- 4.1 Create and Apply cell file - PASS
- 4.2 Create and Install ONOS package - PASS
- 4.3 Starting ONOS service - PASS
- 4.4 Checking if ONOS CLI is ready - PASS
- 4.5 Starting Mininet Topology - PASS
- 4.6 Check whether the flow count is bigger than 116 - PASS
- 4.7 Check whether all flow status are ADDED - PASS
- 4.8 Connectivity for [u'h1', u'h2', u'h3', u'h4'] CASE4 - PASS
- 4.9 Connectivity for [u'olt10', u'vsg10'] CASE4 - PASS
- 4.10 Connectivity for [u'olt5', u'vsg5'] CASE4 - PASS
FAIL
- IP connectivity failed
Case 5: Bridging and Routing sanity test with 4x4 Leaf-spine - PASS
...