Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Test steps

      1. Config IxNetwork with switches (first with 100 (ring) or 10 (full mesh) ) with ring or full mesh topology and two hosts in the adjacent switches (ring) or any other two switches (full mesh).

      2. Start the controller with the features install.

      3. Start the OF protocol of the switch.

      4. Wait until the channel is established and Echo message interaction started.

      5. Enable the traffic between this two hosts, wait until the hosts can ping through each other.

      6. Start the capture of IxNetwork.

      7. Disconnect the link of this two switches, and wait until the traffic recovery

      8. Stop the capture, analyse the messages captured. Write down the time of the port status message T1 and the time of the last flow mod message T2. Caculate the time of Datapath recovery time T=T2-T1

      9. Clean the configuration of controllers and IxNetwork.

      10. Repeat test step 1-9 for three times.

      11. Restart the test with another number of switches.

Test Results

  • Datapath Failure Recovery Time (ring)

    SwitchesFirst (ms)Second (ms)Third (ms)Avg (ms)
    10013819518571063
    2002365212818442112
    3005556510345315063
    4001052790631200710532
    50018281225231814219649
    60035883452973556838916
    70095209767595943977136
  • Datapath Failure Recovery Time (full mesh)

    SwitchesFirst (ms)Second (ms)Third (ms)Avg (ms)
    10702704857739
    20    
    30    
    40    
    50    
    60    
    70    
    80