Test steps
1. Config IxNetwork with switches (first with 100 (ring) or 10 (full mesh) ) with ring or full mesh topology and two hosts in the adjacent switches (ring) or any other two switches (full mesh).
2. Start the controller with the features install.
3. Start the OF protocol of the switch.
4. Wait until the channel is established and Echo message interaction started.
5. Enable the traffic between this two hosts, wait until the hosts can ping through each other.
6. Start the capture of IxNetwork.
7. Disconnect the link of this two switches, and wait until the traffic recovery
8. Stop the capture, analyse the messages captured. Write down the time of the port status message T1 and the time of the last flow mod message T2. Caculate the time of Datapath recovery time T=T2-T1
9. Clean the configuration of controllers and IxNetwork.
10. Repeat test step 1-9 for three times.
11. Restart the test with another number of switches.
Test Results
Datapath Failure Recovery Time (ring)
Switches First (ms) Second (ms) Third (ms) Avg (ms) 100 1381 951 857 1063 200 2365 2128 1844 2112 300 5556 5103 4531 5063 400 10527 9063 12007 10532 500 18281 22523 18142 19649 600 35883 45297 35568 38916 700 95209 76759 59439 77136 Datapath Failure Recovery Time (full mesh)
Switches First (ms) Second (ms) Third (ms) Avg (ms) 10 702 704 857 739 20 304 443 336 361 30 488 334 341 388 40 375 387 700 487 50 311 691 706 569 60 971 587 522 660 70 512 483 721 572 80 524 794 776 698 - Histogram of Datapath Failure Recovery Time
As the result shown, in ring topology, datapath failure recovery time increase significantly with the number of switches. But in full mesh topology, the time is no diffenence with the number of switches.