<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric4/lastSuccessfulBuild/artifact/SRBridging_master_20-builds_graph.jpg", alt="SRBridging", style="width:525px;height:350px;border:0">

commit 55a010394bfadafb3fa8c8f0d1a6707e30d1c31c 46c54e343da96e2087ceaeb029567c603b2d8801 (HEAD -] master, origin/master, origin/HEAD)
Author: DScano [d.scano89@gmailnosignal [howard_hsu@edge-core.com]
AuthorDate: Thu Mon Apr 9 20 15:0129:50 32 2020 +02000800
Commit: Andrea Campanella Carmelo Cascone [andrea@opennetworkingcarmelo@opennetworking.org]
CommitDate: Fri Tue Apr 24 1928 02:0544:04 35 2020 +0000
REST interface for VPLS application
Fix deps link of perfmark

Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR and 3 ONOS instances - PASS

...

  • 28.1 Apply cell to environment - PASS (tick)
  • 28.2 Uninstalling Atomix - PASS (tick)
  • 28.3 Uninstalling ONOS package - PASS (tick)
  • 28.4 Installing Atomix - PASS (tick)
  • 28.5 Installing ONOS package - PASS (tick)
  • 28.6 Set up ONOS secure SSH - PASS (tick)
  • 28.7 Checking ONOS service - PASS (tick)
  • 28.8 Starting ONOS CLI sessions - PASS (tick)
  • 28.9 Checking ONOS nodes - PASS (tick)
  • 28.10 Checking ONOS applications - PASS (tick)
  • 28.11 Starting Mininet Topology - PASS (tick)
  • 28.12 Check whether the flow count is bigger than 212 - PASS (tick)
  • 28.13 Check whether all flow status are ADDED - PASS (tick)
  • 28.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 28.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 28.16 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS (tick)
  • 28.17 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS (tick)
  • 28.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE28 - PASS (tick)
  • 28.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE28 - PASS (tick)
  • 28.20 Stopping Mininet - PASS (tick)
  • 28.21 Copying karaf logs - PASS (tick)

Case 35: Bridging test between two untagged hosts, one on vlan-untagged port and the other on vlan-native port, with single ToR and 3 ONOS instances -

...

PASS

  • 35.1 Apply cell to environment - PASS (tick)
  • 35.2 Uninstalling Atomix - PASS (tick)
  • 35.3 Uninstalling ONOS package - PASS (tick)
  • 35.4 Installing Atomix - PASS (tick)
  • 35.5 Installing ONOS package - PASS (tick)
  • 35.6 Set up ONOS secure SSH - PASS (tick)
  • 35.7 Checking ONOS service - PASS (tick)
  • 35.8 Starting ONOS CLI sessions - PASS (tick)
  • 35.9 Checking ONOS nodes - PASS (tick)
  • 35.10 Checking ONOS applications - PASS (tick)
  • 35.11 Starting Mininet Topology - PASS (tick)
  • 35.12 Check whether the flow count is bigger than 28 - FAIL (error)
  • Flow count looks wrong: 15
  • PASS (tick)
  • 35.13 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • PASS (tick)
  • 35.14 Check whether the flow count of device of:0000000000000001 is bigger than 28 - FAIL (error)
    • Flow count looks wrong: 15
  • PASS (tick)
  • 35.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE35 - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 35.16 Stopping Mininet - PASS (tick)
  • 35.17 Copying karaf logs - PASS (tick)

...