  • 23.1 Apply cell to environment - PASS (tick)
  • 23.2 Uninstalling Atomix - PASS (tick)
  • 23.3 Uninstalling ONOS package - PASS (tick)
  • 23.4 Installing Atomix - PASS (tick)
  • 23.5 Installing ONOS package - PASS (tick)
  • 23.6 Set up ONOS secure SSH - PASS (tick)
  • 23.7 Checking ONOS service - PASS (tick)
  • 23.8 Starting ONOS CLI sessions - PASS (tick)
  • 23.9 Checking ONOS nodes - PASS (tick)
  • 23.10 Checking ONOS applications - PASS (tick)
  • 23.11 Starting Mininet Topology - PASS (tick)
  • 23.12 Check whether the flow count is bigger than 106 - PASS (tick)
  • 23.13 Check whether all flow status are ADDED - PASS (tick)
  • 23.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE23_Before - PASS (tick)
  • 23.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE23_Before - PASS (tick)
  • 23.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 23.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)FAIL (error)
    • Flow count looks wrong: 18
  • 23.18 Check whether the flow count is bigger than 106 - PASS (tick)
  • 23.19 Check whether all flow status are ADDED - FAIL (error)
  • Flow status is wrong!
  • PASS (tick)
  • 23.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE23_After - PASS (tick)
  • 23.21 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE23_After - PASS (tick)
  • 23.22 Stopping Mininet - PASS (tick)
  • 23.23 Copying karaf logs - PASS (tick)

...

  • 53.1 Apply cell to environment - PASS (tick)
  • 53.2 Uninstalling Atomix - PASS (tick)
  • 53.3 Uninstalling ONOS package - PASS (tick)
  • 53.4 Installing Atomix - PASS (tick)
  • 53.5 Installing ONOS package - PASS (tick)
  • 53.6 Set up ONOS secure SSH - PASS (tick)
  • 53.7 Checking ONOS service - PASS (tick)
  • 53.8 Starting ONOS CLI sessions - PASS (tick)
  • 53.9 Checking ONOS nodes - PASS (tick)
  • 53.10 Checking ONOS applications - PASS (tick)
  • 53.11 Starting Mininet Topology - PASS (tick)
  • 53.12 Check whether the flow count is bigger than 104 - PASS (tick)
  • 53.13 Check whether all flow status are ADDED - PASS (tick)
  • 53.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE53_Before - PASS (tick)
  • 53.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE53_Before - PASS (tick)
  • 53.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 53.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 53.18 Check whether the flow count is bigger than 104 - PASS (tick)
  • 53.19 Check whether all flow status are ADDED - PASS (tick)
  • 53.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE53_After - PASS (tick)
  • 53.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE53_After - PASS (tick)
  • 53.22 Stopping Mininet - PASS (tick)
  • 53.23 Copying karaf logs - PASS (tick)

Case 63: Changing port configuration from untagged 10 to tagged 120 with native 110, with 2x2 leaf-spine topology and 3 ONOS instances -

...

PASS

  • 63.1 Apply cell to environment - PASS (tick)
  • 63.2 Uninstalling Atomix - PASS (tick)
  • 63.3 Uninstalling ONOS package - PASS (tick)
  • 63.4 Installing Atomix - PASS (tick)
  • 63.5 Installing ONOS package - PASS (tick)
  • 63.6 Set up ONOS secure SSH - PASS (tick)
  • 63.7 Checking ONOS service - PASS (tick)
  • 63.8 Starting ONOS CLI sessions - PASS (tick)
  • 63.9 Checking ONOS nodes - PASS (tick)
  • 63.10 Checking ONOS applications - PASS (tick)
  • 63.11 Starting Mininet Topology - PASS (tick)
  • 63.12 Check whether the flow count is bigger than 104 - PASS (tick)
  • 63.13 Check whether all flow status are ADDED - PASS (tick)
  • 63.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE63_Before - PASS (tick)
  • 63.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE63_Before - PASS (tick)
  • 63.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 63.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 63.18 Check whether the flow count is bigger than 104 - PASS (tick)
  • 63.19 Check whether all flow status are ADDED - FAIL (error)
  • Flow status is wrong!
  • PASS (tick)
  • 63.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE63_After - PASS (tick)
  • 63.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE63_After - PASS (tick)
  • 63.22 Stopping Mininet - PASS (tick)
  • 63.23 Copying karaf logs - PASS (tick)

...

  • 153.1 Apply cell to environment - PASS (tick)
  • 153.2 Uninstalling Atomix - PASS (tick)
  • 153.3 Uninstalling ONOS package - PASS (tick)
  • 153.4 Installing Atomix - PASS (tick)
  • 153.5 Installing ONOS package - PASS (tick)
  • 153.6 Set up ONOS secure SSH - PASS (tick)
  • 153.7 Checking ONOS service - PASS (tick)
  • 153.8 Starting ONOS CLI sessions - PASS (tick)
  • 153.9 Checking ONOS nodes - PASS (tick)
  • 153.10 Checking ONOS applications - PASS (tick)
  • 153.11 Starting Mininet Topology - PASS (tick)
  • 153.12 Check whether the flow count is bigger than 106 - PASS (tick)
  • 153.13 Check whether all flow status are ADDED - PASS (tick)
  • 153.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE153_Before - PASS (tick)
  • 153.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE153_Before - PASS (tick)
  • 153.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 153.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 153.18 Check whether the flow count is bigger than 106 - PASS (tick)
  • 153.19 Check whether all flow status are ADDED - PASS (tick)
  • 153.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE153_After - PASS (tick)
  • 153.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE153_After - PASS (tick)
  • 153.22 Stopping Mininet - PASS (tick)
  • 153.23 Copying karaf logs - PASS (tick)

Case 163: Changing port configuration from untagged 10 to tagged 20 and native 10, with 2x2 leaf-spine topology and 3 ONOS instances -

...

PASS

  • 163.1 Apply cell to environment - PASS (tick)
  • 163.2 Uninstalling Atomix - PASS (tick)
  • 163.3 Uninstalling ONOS package - PASS (tick)
  • 163.4 Installing Atomix - PASS (tick)
  • 163.5 Installing ONOS package - PASS (tick)
  • 163.6 Set up ONOS secure SSH - PASS (tick)
  • 163.7 Checking ONOS service - PASS (tick)
  • 163.8 Starting ONOS CLI sessions - PASS (tick)
  • 163.9 Checking ONOS nodes - PASS (tick)
  • 163.10 Checking ONOS applications - PASS (tick)
  • 163.11 Starting Mininet Topology - PASS (tick)
  • 163.12 Check whether the flow count is bigger than 106 - PASS (tick)
  • 163.13 Check whether all flow status are ADDED - PASS (tick)
  • 163.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE163_Before - FAIL (error)
    • IP connectivity failed
  • PASS (tick)
  • 163.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE163_Before - PASS (tick)
  • 163.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 163.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 163.18 Check whether the flow count is bigger than 106 - PASS (tick)
  • 163.19 Check whether all flow status are ADDED - PASS (tick)
  • 163.20 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE163_After - FAIL (error)
    • IP connectivity failed
  • PASS (tick)
  • 163.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE163_After - PASS (tick)
  • 163.22 Stopping Mininet - PASS (tick)
  • 163.23 Copying karaf logs - PASS (tick)

...

  • 183.1 Apply cell to environment - PASS (tick)
  • 183.2 Uninstalling Atomix - PASS (tick)
  • 183.3 Uninstalling ONOS package - PASS (tick)
  • 183.4 Installing Atomix - PASS (tick)
  • 183.5 Installing ONOS package - PASS (tick)
  • 183.6 Set up ONOS secure SSH - PASS (tick)
  • 183.7 Checking ONOS service - PASS (tick)
  • 183.8 Starting ONOS CLI sessions - PASS (tick)
  • 183.9 Checking ONOS nodes - PASS (tick)
  • 183.10 Checking ONOS applications - PASS (tick)
  • 183.11 Starting Mininet Topology - PASS (tick)
  • 183.12 Check whether the flow count is bigger than 106 - PASS (tick)
  • 183.13 Check whether all flow status are ADDED - PASS (tick)
  • 183.14 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE183_Before - PASS (tick)
  • 183.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE183_Before - PASS (tick)
  • 183.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 183.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 183.18 Check whether the flow count is bigger than 106 - PASS (tick)
  • 183.19 Check whether all flow status are ADDED - PASS (tick)
  • 183.20 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE183_After - PASS (tick)
  • 183.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE183_After - PASS (tick)
  • 183.22 Stopping Mininet - PASS (tick)
  • 183.23 Copying karaf logs - PASS (tick)

Case 193: Changing port configuration from tagged 20 and native 10 to untagged 20, with 2x2 leaf-spine topology and 3 ONOS instances -

...

PASS

  • 193.1 Apply cell to environment - PASS (tick)
  • 193.2 Uninstalling Atomix - PASS (tick)
  • 193.3 Uninstalling ONOS package - PASS (tick)
  • 193.4 Installing Atomix - PASS (tick)
  • 193.5 Installing ONOS package - PASS (tick)
  • 193.6 Set up ONOS secure SSH - PASS (tick)
  • 193.7 Checking ONOS service - PASS (tick)
  • 193.8 Starting ONOS CLI sessions - PASS (tick)
  • 193.9 Checking ONOS nodes - PASS (tick)
  • 193.10 Checking ONOS applications - PASS (tick)
  • 193.11 Starting Mininet Topology - PASS (tick)
  • 193.12 Check whether the flow count is bigger than 106 - FAIL (error)
    • Flow count looks wrong: 12
  • PASS (tick)
  • 193.13 Check whether all flow status are ADDED - PASS (tick)
  • 193.14 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE193_Before - FAIL (error)
    • IP connectivity failed
  • PASS (tick)
  • 193.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE193_Before - PASS (tick)
  • 193.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - FAIL (error)
  • Flow count looks wrong: 3
  • PASS (tick)
  • 193.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - FAIL (error)
  • Flow count looks wrong: 3
  • PASS (tick)
  • 193.18 Check whether the flow count is bigger than 106 - FAIL (error)
    • Flow count looks wrong: 12
  • PASS (tick)
  • 193.19 Check whether all flow status are ADDED - PASS (tick)
  • 193.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE193_After - FAIL (error)
    • IP connectivity failed
  • PASS (tick)
  • 193.21 Verify full connectivity for [u'h1', u'h2', u'h3'] with tag CASE193_After - PASS (tick)
  • 193.22 Stopping Mininet - PASS (tick)
  • 193.23 Copying karaf logs - PASS (tick)

...

  • 203.1 Apply cell to environment - PASS (tick)
  • 203.2 Uninstalling Atomix - PASS (tick)
  • 203.3 Uninstalling ONOS package - PASS (tick)
  • 203.4 Installing Atomix - PASS (tick)
  • 203.5 Installing ONOS package - PASS (tick)
  • 203.6 Set up ONOS secure SSH - PASS (tick)
  • 203.7 Checking ONOS service - PASS (tick)
  • 203.8 Starting ONOS CLI sessions - PASS (tick)
  • 203.9 Checking ONOS nodes - PASS (tick)
  • 203.10 Checking ONOS applications - PASS (tick)
  • 203.11 Starting Mininet Topology - PASS (tick)
  • 203.12 Check whether the flow count is bigger than 106 - PASS (tick)
  • 203.13 Check whether all flow status are ADDED - PASS (tick)
  • 203.14 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE203_Before - PASS (tick)
  • 203.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE203_Before - PASS (tick)
  • 203.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 203.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 203.18 Check whether the flow count is bigger than 106 - PASS (tick)
  • 203.19 Check whether all flow status are ADDED - PASS (tick)
  • 203.20 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE203_After - PASS (tick)
  • 203.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE203_After - PASS (tick)
  • 203.22 Stopping Mininet - PASS (tick)
  • 203.23 Copying karaf logs - PASS (tick)

Case 213: Changing port configuration from tagged 20 and native 10 to tagged 20 and native 110, with 2x2 leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 213.1 Apply cell to environment - PASS (tick)
  • 213.2 Uninstalling Atomix - PASS (tick)
  • 213.3 Uninstalling ONOS package - PASS (tick)
  • 213.4 Installing Atomix - PASS (tick)
  • 213.5 Installing ONOS package - PASS (tick)
  • 213.6 Set up ONOS secure SSH - PASS (tick)
  • 213.7 Checking ONOS service - PASS (tick)
  • 213.8 Starting ONOS CLI sessions - PASS (tick)
  • 213.9 Checking ONOS nodes - PASS (tick)
  • 213.10 Checking ONOS applications - PASS (tick)
  • 213.11 Starting Mininet Topology - PASS (tick)
  • 213.12 Check whether the flow count is bigger than 106 - PASS (tick)
  • 213.13 Check whether all flow status are ADDED - PASS (tick)FAIL (error)
    • Flow status is wrong!
  • 213.14 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE213_Before - PASS (tick)
  • 213.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE213_Before - PASS (tick)
  • 213.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 213.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 213.18 Check whether the flow count is bigger than 106 - PASS (tick)
  • 213.19 Check whether all flow status are ADDED - PASS (tick)FAIL (error)
    • Flow status is wrong!
  • 213.20 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE213_After - PASS (tick)
  • 213.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE213_After - PASS (tick)
  • 213.22 Stopping Mininet - PASS (tick)
  • 213.23 Copying karaf logs - PASS (tick)

...