Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

HTML
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric4/lastSuccessfulBuild/artifact/SRBridging_unexpected ONOS branchmaster_20-builds_graph.jpg", alt="SRBridging", style="width:525px;height:350px;border:0">

commit 41a7928917456c3aa9785abcc82a0a854da12fd4 f152f4bb2fcbbc957060b55839707d2f6ad438c2 (HEAD -] review/unknown/phased-recoverymaster, origin/master, origin/HEAD)
Author: Charles Chan [rascov@gmail.comONOS Jenkins User [jenkins@onlab.us]
AuthorDate: Fri Feb 14 13:23:57 2020 -0800Tue Jun 2 18:58:58 2020 +0000
Commit: Charles Chan [rascov@gmail.comONOS Jenkins User [jenkins@onlab.us]
CommitDate: Fri May 29 11:54:56 2020 -0700
Phased recoveryTue Jun 2 18:58:58 2020 +0000

Starting snapshot 2.4.0-SNAPSHOT

Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR and 3 ONOS instances - PASS

...

  • 68.1 Apply cell to environment - PASS (tick)
  • 68.2 Uninstalling Atomix - PASS (tick)
  • 68.3 Uninstalling ONOS package - PASS (tick)
  • 68.4 Installing Atomix - PASS (tick)
  • 68.5 Installing ONOS package - PASS (tick)
  • 68.6 Set up ONOS secure SSH - PASS (tick)
  • 68.7 Checking ONOS service - PASS (tick)
  • 68.8 Starting ONOS CLI sessions - PASS (tick)
  • 68.9 Checking ONOS nodes - PASS (tick)
  • 68.10 Checking ONOS applications - PASS (tick)
  • 68.11 Starting Mininet Topology - PASS (tick)
  • 68.12 Check whether the flow count is bigger than 212 - PASS (tick)
  • 68.13 Check whether all flow status are ADDED - PASS (tick)
  • 68.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 68.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 68.16 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS (tick)
  • 68.17 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS (tick)
  • 68.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE68 - PASS (tick)
  • 68.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE68 - PASS (tick)
  • 68.20 Stopping Mininet - PASS (tick)
  • 68.21 Copying karaf logs - PASS (tick)

Case 75: Bridging test between untagged and tagged hosts with different vlan id, with single ToR and 3 ONOS instances -

...

PASS

  • 75.1 Apply cell to environment - PASS (tick)
  • 75.2 Uninstalling Atomix - PASS (tick)
  • 75.3 Uninstalling ONOS package - PASS (tick)
  • 75.4 Installing Atomix - PASS (tick)
  • 75.5 Installing ONOS package - PASS (tick)
  • 75.6 Set up ONOS secure SSH - PASS (tick)
  • 75.7 Checking ONOS service - PASS (tick)
  • 75.8 Starting ONOS CLI sessions - PASS (tick)
  • 75.9 Checking ONOS nodes - PASS (tick)
  • 75.10 Checking ONOS applications - PASS (tick)
  • 75.11 Starting Mininet Topology - PASS (tick)
  • 75.12 Check whether the flow count is bigger than 28 - FAIL (error)
  • Flow count looks wrong: 17
  • PASS (tick)
  • 75.13 Check whether all flow status are ADDED - PASS (tick)
  • 75.14 Check whether the flow count of device of:0000000000000001 is bigger than 28 - FAIL (error)
  • Flow count looks wrong: 17
  • PASS (tick)
  • 75.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE75 - PASS (tick)
  • 75.16 Stopping Mininet - PASS (tick)
  • 75.17 Copying karaf logs - PASS (tick)

...