Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

HTML
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric3/lastSuccessfulBuild/artifact/SRBridging_onos-2.2_20-builds_graph.jpg", alt="SRBridging", style="width:525px;height:350px;border:0">

commit 5bdaf106e4b30208d6acee6ad5bf1d58c9057d66 f198430fee8d188a8704f0cc06f403f10df70c3a (HEAD -] onos-2.2, origin/onos-2.2)
Author: Charles Chan Andrea Campanella [rascov@gmailandrea@opennetworking.comorg]
AuthorDate: Mon Aug 10 1618:3406:32 42 2020 -0700+0200
Commit: Charles Chan Andrea Campanella [charles@opennetworkingandrea@opennetworking.org]
CommitDate: Tue Wed Aug 11 2212 06:4947:56 09 2020 +0000
[VOL-2950][VOL-3110][AETHER-457] Fix a bug in component readiness check
Ports and port description are not cleared up properly upon removal

Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR, ovs switches and 3 ONOS instances - PASS

...

  • 5.1 Constructing test variables - PASS (tick)
  • 5.2 Apply cell to environment - PASS (tick)
  • 5.3 Uninstalling Atomix - PASS (tick)
  • 5.4 Uninstalling ONOS package - PASS (tick)
  • 5.5 Creating ONOS package - PASS (tick)
  • 5.6 Installing Atomix - PASS (tick)
  • 5.7 Installing ONOS package - PASS (tick)
  • 5.8 Set up ONOS secure SSH - PASS (tick)
  • 5.9 Checking ONOS service - PASS (tick)
  • 5.10 Starting ONOS CLI sessions - PASS (tick)
  • 5.11 Checking ONOS nodes - PASS (tick)
  • 5.12 Checking ONOS applications - PASS (tick)
  • 5.13 Set logging levels - PASS (tick)
  • 5.14 Set ONOS configurations - PASS (tick)
  • 5.15 Starting Mininet Topology - PASS (tick)
  • 5.16 Check whether the flow count is bigger than 28 - PASS (tick)
  • 5.17 Check whether all flow status are ADDED - PASS (tick)
  • 5.18 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS (tick)
  • 5.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE5 - PASS (tick)
  • 5.20 Stopping Mininet - PASS (tick)
  • 5.21 Copying karaf logs - PASS (tick)

Case 6: Bridging test between two untagged hosts on vlan-untagged port, with dual-homed ToR, ovs switches and 3 ONOS instances -

...

PASS

  • 6.1 Apply cell to environment - PASS (tick)
  • 6.2 Uninstalling Atomix - PASS (tick)
  • 6.3 Uninstalling ONOS package - PASS (tick)
  • 6.4 Installing Atomix - PASS (tick)
  • 6.5 Installing ONOS package - PASS (tick)
  • 6.6 Set up ONOS secure SSH - PASS (tick)
  • 6.7 Checking ONOS service - PASS (tick)
  • 6.8 Starting ONOS CLI sessions - PASS (tick)
  • 6.9 Checking ONOS nodes - PASS (tick)
  • 6.10 Checking ONOS applications - PASS (tick)
  • 6.11 Set logging levels - PASS (tick)
  • 6.12 Set ONOS configurations - PASS (tick)
  • 6.13 Starting Mininet Topology - PASS (tick)
  • 6.14 Check whether the flow count is bigger than 74 - PASS (tick)
  • 6.15 Check whether all flow status are ADDED - FAIL (error)
  • Flow status is wrong!
  • PASS (tick)
  • 6.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - FAIL (error)
    • Flow count looks wrong: 25
  • PASS (tick)
  • 6.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 6.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE6 - PASS (tick)
  • 6.19 Stopping Mininet - PASS (tick)
  • 6.20 Copying karaf logs - PASS (tick)

...

  • 16.1 Apply cell to environment - PASS (tick)
  • 16.2 Uninstalling Atomix - PASS (tick)
  • 16.3 Uninstalling ONOS package - PASS (tick)
  • 16.4 Installing Atomix - PASS (tick)
  • 16.5 Installing ONOS package - PASS (tick)
  • 16.6 Set up ONOS secure SSH - PASS (tick)
  • 16.7 Checking ONOS service - PASS (tick)
  • 16.8 Starting ONOS CLI sessions - PASS (tick)
  • 16.9 Checking ONOS nodes - PASS (tick)
  • 16.10 Checking ONOS applications - PASS (tick)
  • 16.11 Set logging levels - PASS (tick)
  • 16.12 Set ONOS configurations - PASS (tick)
  • 16.13 Starting Mininet Topology - PASS (tick)
  • 16.14 Check whether the flow count is bigger than 74 - PASS (tick)
  • 16.15 Check whether all flow status are ADDED - PASS (tick)
  • 16.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 16.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 16.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE16 - PASS (tick)
  • 16.19 Stopping Mininet - PASS (tick)
  • 16.20 Copying karaf logs - PASS (tick)

Case 17: Bridging test between two tagged hosts, with 2x2 leaf-spine topology, ovs switches and 3 ONOS instances -

...

FAIL

  • 17.1 Apply cell to environment - PASS (tick)
  • 17.2 Uninstalling Atomix - PASS (tick)
  • 17.3 Uninstalling ONOS package - PASS (tick)
  • 17.4 Installing Atomix - PASS (tick)
  • 17.5 Installing ONOS package - PASS (tick)
  • 17.6 Set up ONOS secure SSH - PASS (tick)
  • 17.7 Checking ONOS service - PASS (tick)
  • 17.8 Starting ONOS CLI sessions - PASS (tick)
  • 17.9 Checking ONOS nodes - PASS (tick)
  • 17.10 Checking ONOS applications - PASS (tick)
  • 17.11 Set logging levels - PASS (tick)
  • 17.12 Set ONOS configurations - PASS (tick)
  • 17.13 Starting Mininet Topology - PASS (tick)
  • 17.14 Check whether the flow count is bigger than 74 - PASS (tick)
  • 17.15 Check whether all flow status are ADDED - PASS (tick)
  • 17.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 17.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)FAIL (error)
    • Flow count looks wrong: 22
  • 17.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE17 - PASS (tick)
  • 17.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE17 - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 17.20 Stopping Mininet - PASS (tick)
  • 17.21 Copying karaf logs - PASS (tick)

...

  • 26.1 Apply cell to environment - PASS (tick)
  • 26.2 Uninstalling Atomix - PASS (tick)
  • 26.3 Uninstalling ONOS package - PASS (tick)
  • 26.4 Installing Atomix - PASS (tick)
  • 26.5 Installing ONOS package - PASS (tick)
  • 26.6 Set up ONOS secure SSH - PASS (tick)
  • 26.7 Checking ONOS service - PASS (tick)
  • 26.8 Starting ONOS CLI sessions - PASS (tick)
  • 26.9 Checking ONOS nodes - PASS (tick)
  • 26.10 Checking ONOS applications - PASS (tick)
  • 26.11 Set logging levels - PASS (tick)
  • 26.12 Set ONOS configurations - PASS (tick)
  • 26.13 Starting Mininet Topology - PASS (tick)
  • 26.14 Check whether the flow count is bigger than 74 - PASS (tick)
  • 26.15 Check whether all flow status are ADDED - PASS (tick)
  • 26.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 26.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 26.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE26 - PASS (tick)
  • 26.19 Stopping Mininet - PASS (tick)
  • 26.20 Copying karaf logs - PASS (tick)

Case 27: Bridging test between two untagged hosts on vlan-native port, with 2x2 leaf-spine topology, ovs switches and 3 ONOS instances -

...

FAIL

  • 27.1 Apply cell to environment - PASS (tick)
  • 27.2 Uninstalling Atomix - PASS (tick)
  • 27.3 Uninstalling ONOS package - PASS (tick)
  • 27.4 Installing Atomix - PASS (tick)
  • 27.5 Installing ONOS package - PASS (tick)
  • 27.6 Set up ONOS secure SSH - PASS (tick)
  • 27.7 Checking ONOS service - PASS (tick)
  • 27.8 Starting ONOS CLI sessions - PASS (tick)
  • 27.9 Checking ONOS nodes - PASS (tick)
  • 27.10 Checking ONOS applications - PASS (tick)
  • 27.11 Set logging levels - PASS (tick)
  • 27.12 Set ONOS configurations - PASS (tick)
  • 27.13 Starting Mininet Topology - PASS (tick)
  • 27.14 Check whether the flow count is bigger than 74 - PASS (tick)
  • 27.15 Check whether all flow status are ADDED - PASS (tick)FAIL (error)
    • Flow status is wrong!
  • 27.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)FAIL (error)
    • Flow count looks wrong: 20
  • 27.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 27.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE27 - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 27.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE27 - PASS (tick)
  • 27.20 Stopping Mininet - PASS (tick)
  • 27.21 Copying karaf logs - PASS (tick)

...

  • 47.1 Apply cell to environment - PASS (tick)
  • 47.2 Uninstalling Atomix - PASS (tick)
  • 47.3 Uninstalling ONOS package - PASS (tick)
  • 47.4 Installing Atomix - PASS (tick)
  • 47.5 Installing ONOS package - PASS (tick)
  • 47.6 Set up ONOS secure SSH - PASS (tick)
  • 47.7 Checking ONOS service - PASS (tick)
  • 47.8 Starting ONOS CLI sessions - PASS (tick)
  • 47.9 Checking ONOS nodes - PASS (tick)
  • 47.10 Checking ONOS applications - PASS (tick)
  • 47.11 Set logging levels - PASS (tick)
  • 47.12 Set ONOS configurations - PASS (tick)
  • 47.13 Starting Mininet Topology - PASS (tick)
  • 47.14 Check whether the flow count is bigger than 74 - PASS (tick)
  • 47.15 Check whether all flow status are ADDED - PASS (tick)
  • 47.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 47.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 47.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE47 - PASS (tick)
  • 47.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE47 - PASS (tick)
  • 47.20 Stopping Mininet - PASS (tick)
  • 47.21 Copying karaf logs - PASS (tick)

Case 48: Bridging test between untagged host and tagged host, with 2x4 dual-homed leaf-spine topology, ovs switches and 3 ONOS instances -

...

PASS

  • 48.1 Apply cell to environment - PASS (tick)
  • 48.2 Uninstalling Atomix - PASS (tick)
  • 48.3 Uninstalling ONOS package - PASS (tick)
  • 48.4 Installing Atomix - PASS (tick)
  • 48.5 Installing ONOS package - PASS (tick)
  • 48.6 Set up ONOS secure SSH - PASS (tick)
  • 48.7 Checking ONOS service - PASS (tick)
  • 48.8 Starting ONOS CLI sessions - PASS (tick)
  • 48.9 Checking ONOS nodes - PASS (tick)
  • 48.10 Checking ONOS applications - PASS (tick)
  • 48.11 Set logging levels - PASS (tick)
  • 48.12 Set ONOS configurations - PASS (tick)
  • 48.13 Starting Mininet Topology - PASS (tick)
  • 48.14 Check whether the flow count is bigger than 212 - PASS (tick)
  • 48.15 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • PASS (tick)
  • 48.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 48.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 48.18 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS (tick)
  • 48.19 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS (tick)
  • 48.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE48 - PASS (tick)
  • 48.21 Verify full connectivity for [u'h3', u'h4'] with tag CASE48 - PASS (tick)
  • 48.22 Stopping Mininet - PASS (tick)
  • 48.23 Copying karaf logs - PASS (tick)

...

  • 58.1 Apply cell to environment - PASS (tick)
  • 58.2 Uninstalling Atomix - PASS (tick)
  • 58.3 Uninstalling ONOS package - PASS (tick)
  • 58.4 Installing Atomix - PASS (tick)
  • 58.5 Installing ONOS package - PASS (tick)
  • 58.6 Set up ONOS secure SSH - PASS (tick)
  • 58.7 Checking ONOS service - PASS (tick)
  • 58.8 Starting ONOS CLI sessions - PASS (tick)
  • 58.9 Checking ONOS nodes - PASS (tick)
  • 58.10 Checking ONOS applications - PASS (tick)
  • 58.11 Set logging levels - PASS (tick)
  • 58.12 Set ONOS configurations - PASS (tick)
  • 58.13 Starting Mininet Topology - PASS (tick)
  • 58.14 Check whether the flow count is bigger than 212 - PASS (tick)
  • 58.15 Check whether all flow status are ADDED - PASS (tick)
  • 58.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 58.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 58.18 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS (tick)
  • 58.19 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS (tick)
  • 58.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE58 - PASS (tick)
  • 58.21 Verify full connectivity for [u'h3', u'h4'] with tag CASE58 - PASS (tick)
  • 58.22 Stopping Mininet - PASS (tick)
  • 58.23 Copying karaf logs - PASS (tick)

Case 65: Bridging test between two tagged hosts with different vlan id, with single ToR, ovs switches and 3 ONOS instances -

...

PASS

  • 65.1 Apply cell to environment - PASS (tick)
  • 65.2 Uninstalling Atomix - PASS (tick)
  • 65.3 Uninstalling ONOS package - PASS (tick)
  • 65.4 Installing Atomix - PASS (tick)
  • 65.5 Installing ONOS package - PASS (tick)
  • 65.6 Set up ONOS secure SSH - PASS (tick)
  • 65.7 Checking ONOS service - PASS (tick)
  • 65.8 Starting ONOS CLI sessions - PASS (tick)
  • 65.9 Checking ONOS nodes - PASS (tick)
  • 65.10 Checking ONOS applications - PASS (tick)
  • 65.11 Set logging levels - PASS (tick)
  • 65.12 Set ONOS configurations - PASS (tick)
  • 65.13 Starting Mininet Topology - PASS (tick)
  • 65.14 Check whether the flow count is bigger than 28 - FAIL (error)
    • Flow count looks wrong; found 19, expecting at least 28
  • PASS (tick)
  • 65.15 Check whether all flow status are ADDED - PASS (tick)
  • 65.16 Check whether the flow count of device of:0000000000000001 is bigger than 28 - FAIL (error)
  • Flow count looks wrong: 19
  • PASS (tick)
  • 65.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE65 - PASS (tick)
  • 65.18 Stopping Mininet - PASS (tick)
  • 65.19 Copying karaf logs - PASS (tick)

...

  • 67.1 Apply cell to environment - PASS (tick)
  • 67.2 Uninstalling Atomix - PASS (tick)
  • 67.3 Uninstalling ONOS package - PASS (tick)
  • 67.4 Installing Atomix - PASS (tick)
  • 67.5 Installing ONOS package - PASS (tick)
  • 67.6 Set up ONOS secure SSH - PASS (tick)
  • 67.7 Checking ONOS service - PASS (tick)
  • 67.8 Starting ONOS CLI sessions - PASS (tick)
  • 67.9 Checking ONOS nodes - PASS (tick)
  • 67.10 Checking ONOS applications - PASS (tick)
  • 67.11 Set logging levels - PASS (tick)
  • 67.12 Set ONOS configurations - PASS (tick)
  • 67.13 Starting Mininet Topology - PASS (tick)
  • 67.14 Check whether the flow count is bigger than 74 - PASS (tick)
  • 67.15 Check whether all flow status are ADDED - PASS (tick)
  • 67.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 67.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 67.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE67 - PASS (tick)
  • 67.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE67 - PASS (tick)
  • 67.20 Stopping Mininet - PASS (tick)
  • 67.21 Copying karaf logs - PASS (tick)

Case 68: Bridging test between two tagged hosts with different vlan id, with 2x4 dual-homed leaf-spine topology, ovs switches and 3 ONOS instances -

...

PASS

  • 68.1 Apply cell to environment - PASS (tick)
  • 68.2 Uninstalling Atomix - PASS (tick)
  • 68.3 Uninstalling ONOS package - PASS (tick)
  • 68.4 Installing Atomix - PASS (tick)
  • 68.5 Installing ONOS package - PASS (tick)
  • 68.6 Set up ONOS secure SSH - PASS (tick)
  • 68.7 Checking ONOS service - PASS (tick)
  • 68.8 Starting ONOS CLI sessions - PASS (tick)
  • 68.9 Checking ONOS nodes - PASS (tick)
  • 68.10 Checking ONOS applications - PASS (tick)
  • 68.11 Set logging levels - PASS (tick)
  • 68.12 Set ONOS configurations - PASS (tick)
  • 68.13 Starting Mininet Topology - PASS (tick)
  • 68.14 Check whether the flow count is bigger than 212 - PASS (tick)
  • 68.15 Check whether all flow status are ADDED - PASS (tick)
  • 68.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 68.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - FAIL (error)
  • Flow count looks wrong: 23
  • PASS (tick)
  • 68.18 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS (tick)
  • 68.19 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS (tick)
  • 68.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE68 - PASS (tick)
  • 68.21 Verify full connectivity for [u'h3', u'h4'] with tag CASE68 - PASS (tick)
  • 68.22 Stopping Mininet - PASS (tick)
  • 68.23 Copying karaf logs - PASS (tick)

...