Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

HTML
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric4/lastSuccessfulBuild/artifact/SRDynamicConf_master_20-builds_graph.jpg", alt="SRDynamicConf", style="width:525px;height:350px;border:0">

commit a1b624eaa1d0241b2c8161c7854f012664908353 b0dfbc89626a41624eec432ea3086501141bd0e7 (HEAD -] master, origin/master, origin/HEAD)
Author: Thomas Vachuska Andrea Campanella [tom@opennetworkingandrea@opennetworking.org]
AuthorDate: Fri Jul 31 14:20:32 2020 -0700Mon Aug 10 18:06:42 2020 +0200
Commit: Sean Condon Andrea Campanella [sean@opennetworkingandrea@opennetworking.org]
CommitDate: Mon Wed Aug 3 0712 06:5547:09 57 2020 +0000
Removing the host drop-shadow from the topo GUI2

Case 13: Changing port configuration from untagged 10 to tagged 10, with 2x2 leaf-spine topology and 3 ONOS instances - PASS

  • 13.1 Constructing test variables - PASS (tick)
  • 13.2 Apply cell to environment - PASS (tick)
  • 13.3 Uninstalling Atomix - PASS (tick)
  • 13.4 Uninstalling ONOS package - PASS (tick)
  • 13.5 Creating ONOS package - PASS (tick)
  • 13.6 Installing Atomix - PASS (tick)
  • 13.7 Installing ONOS package - PASS (tick)
  • 13.8 Set up ONOS secure SSH - PASS (tick)
  • 13.9 Checking ONOS service - PASS (tick)
  • 13.10 Starting ONOS CLI sessions - PASS (tick)
  • 13.11 Checking ONOS nodes - PASS (tick)
  • 13.12 Checking ONOS applications - PASS (tick)
  • 13.13 Set logging levels - PASS (tick)
  • 13.14 Set ONOS configurations - PASS (tick)
  • 13.15 Starting Mininet Topology - PASS (tick)
  • 13.16 Check whether the flow count is bigger than 104 - PASS (tick)
  • 13.17 Check whether all flow status are ADDED - PASS (tick)
  • 13.18 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE13_Before - PASS (tick)
  • 13.19 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 13.20 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 13.21 Check whether the flow count is bigger than 104 - PASS (tick)
  • 13.22 Check whether all flow status are ADDED - PASS (tick)
  • 13.23 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE13_After - PASS (tick)
  • 13.24 Stopping Mininet - PASS (tick)
  • 13.25 Copying karaf logs - PASS (tick)

...


Ports and port description are not cleared up properly upon removal
--
(cherry picked from commit f198430fee8d188a8704f0cc06f403f10df70c3a)

Case 13: Changing port configuration from untagged 10 to tagged

...

10, with 2x2 leaf-spine topology and 3 ONOS instances - FAIL