- 68.1 Apply cell to environment - PASS
- 68.2 Uninstalling Atomix - PASS
- 68.3 Uninstalling ONOS package - PASS
- 68.4 Create Cluster Config - PASS
- 68.5 Installing Atomix via docker containers - PASS
- 68.6 Installing ONOS via docker containers - PASS
- 68.7 Set up ONOS secure SSH - PASS
- 68.8 Starting ONOS CLI sessions - PASS
- 68.9 Checking ONOS nodes - PASS
- 68.10 Checking ONOS applications - PASS
- 68.11 Set logging levels - PASS
- 68.12 Set ONOS configurations - PASS
- 68.13 Starting Mininet Topology - PASS
- 68.14 Configure switches in ONOS - PASS
- 68.15 Check whether the flow count is bigger than 212 - PASS
- 68.16 Check whether all flow status are ADDED - PASS
- 68.17 Check whether the flow count of device device:bmv2:leaf1 is bigger than 53 - PASS
- 68.18 Check whether the flow count of device device:bmv2:leaf2 is bigger than 53 - PASS
- 68.19 Check whether the flow count of device device:bmv2:leaf3 is bigger than 53 - PASS
- 68.20 Check whether the flow count of device device:bmv2:leaf4 is bigger than 53 - PASS
- 68.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE68 - PASS
- 68.22 Verify full connectivity for [u'h3', u'h4'] with tag CASE68 - PASS
- 68.23 Stopping Mininet - PASS
- 68.24 Copying karaf logs - PASS
Case 75: Bridging test between untagged and tagged hosts with different vlan id, with single ToR, stratum switches and 3 ONOS instances -
...
PASS
- 75.1 Apply cell to environment - PASS
- 75.2 Uninstalling Atomix - PASS
- 75.3 Uninstalling ONOS package - PASS
- 75.4 Create Cluster Config - PASS
- 75.5 Installing Atomix via docker containers - PASS
- 75.6 Installing ONOS via docker containers - PASS
- 75.7 Set up ONOS secure SSH - PASS
- 75.8 Starting ONOS CLI sessions - PASS
- 75.9 Checking ONOS nodes - PASS
- 75.10 Checking ONOS applications - PASS
- 75.11 Set logging levels - PASS
- 75.12 Set ONOS configurations - PASS
- 75.13 Starting Mininet Topology - PASS
- 75.14 Configure switches in ONOS - PASS
- 75.15 Check whether the flow count is bigger than 28 - FAIL Flow count looks wrong; found 15, expecting at least 28
- PASS
- 75.16 Check whether all flow status are ADDED - PASS
- 75.17 Check whether the flow count of device device:bmv2:leaf1 is bigger than 28 - FAIL Flow count looks wrong: 15
- PASS
- 75.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE75 - PASS
- 75.19 Stopping Mininet - PASS
- 75.20 Copying karaf logs - PASS
...