  • 7.1 Apply cell to environment - PASS (tick)
  • 7.2 Uninstalling Atomix - PASS (tick)
  • 7.3 Uninstalling ONOS package - PASS (tick)
  • 7.4 Create Cluster Config - PASS (tick)
  • 7.5 Installing Atomix via docker containers - PASS (tick)
  • 7.6 Installing ONOS via docker containers - PASS (tick)
  • 7.7 Set up ONOS secure SSH - PASS (tick)
  • 7.8 Starting ONOS CLI sessions - PASS (tick)
  • 7.9 Checking ONOS nodes - PASS (tick)
  • 7.10 Checking ONOS applications - PASS (tick)
  • 7.11 Set logging levels - PASS (tick)
  • 7.12 Set ONOS configurations - PASS (tick)
  • 7.13 Starting Mininet Topology - PASS (tick)
  • 7.14 Configure switches in ONOS - PASS (tick)
  • 7.15 Check whether the flow count is bigger than 64 - PASS (tick)
  • 7.16 Check whether all flow status are ADDED - PASS (tick)
  • 7.17 Check whether the flow count of device device:bmv2:leaf1 is bigger than 32 - PASS (tick)
  • 7.18 Check whether the flow count of device device:bmv2:leaf2 is bigger than 32 - PASS (tick)
  • 7.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE7 - PASS (tick)
  • 7.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE7 - PASS (tick)
  • 7.21 Stopping Mininet - PASS (tick)
  • 7.22 Copying karaf logs - PASS (tick)

Case 8: Bridging test between two untagged hosts on vlan-untagged port, with 2x4 dual-homed leaf-spine topology, stratum switches and 3 ONOS instances -

...

FAIL

  • 8.1 Apply cell to environment - PASS (tick)
  • 8.2 Uninstalling Atomix - PASS (tick)
  • 8.3 Uninstalling ONOS package - PASS (tick)
  • 8.4 Create Cluster Config - PASS (tick)
  • 8.5 Installing Atomix via docker containers - PASS (tick)
  • 8.6 Installing ONOS via docker containers - PASS (tick)
  • 8.7 Set up ONOS secure SSH - PASS (tick)
  • 8.8 Starting ONOS CLI sessions - PASS (tick)
  • 8.9 Checking ONOS nodes - PASS (tick)
  • 8.10 Checking ONOS applications - PASS (tick)
  • 8.11 Set logging levels - PASS (tick)
  • 8.12 Set ONOS configurations - PASS (tick)
  • 8.13 Starting Mininet Topology - PASS (tick)
  • 8.14 Configure switches in ONOS - PASS (tick)
  • 8.15 Check whether the flow count is bigger than 212 - PASS (tick)
  • 8.16 Check whether all flow status are ADDED - PASS (tick)
  • 8.17 Check whether the flow count of device device:bmv2:leaf1 is bigger than 53 - PASS (tick)
  • 8.18 Check whether the flow count of device device:bmv2:leaf2 is bigger than 53 - PASS (tick)FAIL (error)
    • Flow count looks wrong: 24
  • 8.19 Check whether the flow count of device device:bmv2:leaf3 is bigger than 53 - PASS (tick)
  • 8.20 Check whether the flow count of device device:bmv2:leaf4 is bigger than 53 - PASS (tick)
  • 8.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE8 - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 8.22 Verify full connectivity for [u'h3', u'h4'] with tag CASE8 - PASS (tick)
  • 8.23 Stopping Mininet - PASS (tick)
  • 8.24 Copying karaf logs - PASS (tick)

...

  • 77.1 Apply cell to environment - PASS (tick)
  • 77.2 Uninstalling Atomix - PASS (tick)
  • 77.3 Uninstalling ONOS package - PASS (tick)
  • 77.4 Create Cluster Config - PASS (tick)
  • 77.5 Installing Atomix via docker containers - PASS (tick)
  • 77.6 Installing ONOS via docker containers - PASS (tick)
  • 77.7 Set up ONOS secure SSH - PASS (tick)
  • 77.8 Starting ONOS CLI sessions - PASS (tick)
  • 77.9 Checking ONOS nodes - PASS (tick)
  • 77.10 Checking ONOS applications - PASS (tick)
  • 77.11 Set logging levels - PASS (tick)
  • 77.12 Set ONOS configurations - PASS (tick)
  • 77.13 Starting Mininet Topology - PASS (tick)
  • 77.14 Configure switches in ONOS - PASS (tick)
  • 77.15 Check whether the flow count is bigger than 64 - PASS (tick)
  • 77.16 Check whether all flow status are ADDED - PASS (tick)
  • 77.17 Check whether the flow count of device device:bmv2:leaf1 is bigger than 32 - PASS (tick)
  • 77.18 Check whether the flow count of device device:bmv2:leaf2 is bigger than 32 - PASS (tick)
  • 77.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE77 - PASS (tick)
  • 77.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE77 - PASS (tick)
  • 77.21 Stopping Mininet - PASS (tick)
  • 77.22 Copying karaf logs - PASS (tick)

Case 78: Bridging test between untagged and tagged hosts with different vlan id, with 2x4 dual-homed leaf-spine topology, stratum switches and 3 ONOS instances -

...

FAIL

  • 78.1 Apply cell to environment - PASS (tick)
  • 78.2 Uninstalling Atomix - PASS (tick)
  • 78.3 Uninstalling ONOS package - PASS (tick)
  • 78.4 Create Cluster Config - PASS (tick)
  • 78.5 Installing Atomix via docker containers - PASS (tick)
  • 78.6 Installing ONOS via docker containers - PASS (tick)
  • 78.7 Set up ONOS secure SSH - PASS (tick)
  • 78.8 Starting ONOS CLI sessions - PASS (tick)
  • 78.9 Checking ONOS nodes - PASS (tick)
  • 78.10 Checking ONOS applications - PASS (tick)
  • 78.11 Set logging levels - PASS (tick)
  • 78.12 Set ONOS configurations - PASS (tick)
  • 78.13 Starting Mininet Topology - PASS (tick)
  • 78.14 Configure switches in ONOS - PASS (tick)
  • 78.15 Check whether the flow count is bigger than 212 - PASS (tick)
  • 78.16 Check whether all flow status are ADDED - PASS (tick)
  • 78.17 Check whether the flow count of device device:bmv2:leaf1 is bigger than 53 - PASS (tick)
  • 78.18 Check whether the flow count of device device:bmv2:leaf2 is bigger than 53 - PASS (tick)
  • 78.19 Check whether the flow count of device device:bmv2:leaf3 is bigger than 53 - PASS (tick)FAIL (error)
    • Flow count looks wrong: 13
  • 78.20 Check whether the flow count of device device:bmv2:leaf4 is bigger than 53 - PASS (tick)
  • 78.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE78 - PASS (tick)
  • 78.22 Verify full connectivity for [u'h3', u'h4'] with tag CASE78 - PASS (tick)
  • 78.23 Stopping Mininet - PASS (tick)
  • 78.24 Copying karaf logs - PASS (tick)