Due to a ransomware attack, the wiki was reverted to a July 2022 version. . We apologize for the lack of a more recent valid backup.
...
HTML |
---|
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric4/lastSuccessfulBuild/artifact/SRBridging-stratum_master_20-builds_graph.jpg", alt="SRBridging-stratum", style="width:525px;height:350px;border:0"> |
commit b58e9c9c02abe88b6e4160705ed387740ede99c4 8479dd1eb35e69448c50acd20fcf9dbb02d74c4f (HEAD -] master, origin/master, origin/HEAD)
Author: pierventre Andrea Campanella [pier@opennetworkingandrea@opennetworking.org]
AuthorDate: Fri May 22 09:42:31 2020 -0700Mon Oct 19 10:44:15 2020 +0200
Commit: pierventre Andrea Campanella [pier@opennetworkingandrea@opennetworking.org]
CommitDate: Fri Mon Oct 16 0819 14:2115:14 37 2020 +0200
[AETHER-38] Extract pipeline-dependent code from current T3 implementation0000
Escaping regex reserved chars
--
(cherry picked from commit 84e2ecffb63420ac8b8221bbe9cb353c0176a5cd)
Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR, stratum switches and 3 ONOS instances - PASS
...
- 26.1 Apply cell to environment - PASS
- 26.2 Uninstalling Atomix - PASS
- 26.3 Uninstalling ONOS package - PASS
- 26.4 Create Cluster Config - PASS
- 26.5 Installing Atomix via docker containers - PASS
- 26.6 Installing ONOS via docker containers - PASS
- 26.7 Set up ONOS secure SSH - PASS
- 26.8 Starting ONOS CLI sessions - PASS
- 26.9 Checking ONOS nodes - PASS
- 26.10 Checking ONOS applications - PASS
- 26.11 Set logging levels - PASS
- 26.12 Set ONOS configurations - PASS
- 26.13 Starting Mininet Topology - PASS
- 26.14 Configure switches in ONOS - PASS
- 26.15 Check whether the flow count is bigger than 74 - PASS
- 26.16 Check whether all flow status are ADDED - PASS
- 26.17 Check whether the flow count of device device:bmv2:leaf1 is bigger than 37 - PASS
- 26.18 Check whether the flow count of device device:bmv2:leaf2 is bigger than 37 - PASS
- 26.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE26 - PASS
- 26.20 Stopping Mininet - PASS
- 26.21 Copying karaf logs - PASS
Case 27: Bridging test between two untagged hosts on vlan-native port, with 2x2 leaf-spine topology, stratum switches and 3 ONOS instances -
...
PASS
- 27.1 Apply cell to environment - PASS
- 27.2 Uninstalling Atomix - PASS
- 27.3 Uninstalling ONOS package - PASS
- 27.4 Create Cluster Config - PASS
- 27.5 Installing Atomix via docker containers - PASS
- 27.6 Installing ONOS via docker containers - PASS
- 27.7 Set up ONOS secure SSH - PASS
- 27.8 Starting ONOS CLI sessions - PASS
- 27.9 Checking ONOS nodes - PASS
- 27.10 Checking ONOS applications - PASS
- 27.11 Set logging levels - PASS
- 27.12 Set ONOS configurations - PASS
- 27.13 Starting Mininet Topology - PASS
- 27.14 Configure switches in ONOS - PASS
- 27.15 Check whether the flow count is bigger than 64 - PASS
- 27.16 Check whether all flow status are ADDED - PASS
- 27.17 Check whether the flow count of device device:bmv2:leaf1 is bigger than 32 - PASS
- 27.18 Check whether the flow count of device device:bmv2:leaf2 is bigger than 32 - FAIL
- Flow count looks wrong: 19
- PASS
- 27.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE27 - PASS
- 27.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE27 - FAIL
- IP connectivity failed
- PASS
- 27.21 Stopping Mininet - PASS
- 27.22 Copying karaf logs - PASS
...
- 58.1 Apply cell to environment - PASS
- 58.2 Uninstalling Atomix - PASS
- 58.3 Uninstalling ONOS package - PASS
- 58.4 Create Cluster Config - PASS
- 58.5 Installing Atomix via docker containers - PASS
- 58.6 Installing ONOS via docker containers - PASS
- 58.7 Set up ONOS secure SSH - PASS
- 58.8 Starting ONOS CLI sessions - PASS
- 58.9 Checking ONOS nodes - PASS
- 58.10 Checking ONOS applications - PASS
- 58.11 Set logging levels - PASS
- 58.12 Set ONOS configurations - PASS
- 58.13 Starting Mininet Topology - PASS
- 58.14 Configure switches in ONOS - PASS
- 58.15 Check whether the flow count is bigger than 212 - PASS
- 58.16 Check whether all flow status are ADDED - PASS
- 58.17 Check whether the flow count of device device:bmv2:leaf1 is bigger than 53 - PASS
- 58.18 Check whether the flow count of device device:bmv2:leaf2 is bigger than 53 - PASS
- 58.19 Check whether the flow count of device device:bmv2:leaf3 is bigger than 53 - PASS
- 58.20 Check whether the flow count of device device:bmv2:leaf4 is bigger than 53 - PASS
- 58.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE58 - PASS
- 58.22 Verify full connectivity for [u'h3', u'h4'] with tag CASE58 - PASS
- 58.23 Stopping Mininet - PASS
- 58.24 Copying karaf logs - PASS
Case 65: Bridging test between two tagged hosts with different vlan id, with single ToR, stratum switches and 3 ONOS instances -
...
PASS
- 65.1 Apply cell to environment - PASS
- 65.2 Uninstalling Atomix - PASS
- 65.3 Uninstalling ONOS package - PASS
- 65.4 Create Cluster Config - PASS
- 65.5 Installing Atomix via docker containers - PASS
- 65.6 Installing ONOS via docker containers - PASS
- 65.7 Set up ONOS secure SSH - PASS
- 65.8 Starting ONOS CLI sessions - PASS
- 65.9 Checking ONOS nodes - PASS
- 65.10 Checking ONOS applications - PASS
- 65.11 Set logging levels - PASS
- 65.12 Set ONOS configurations - PASS
- 65.13 Starting Mininet Topology - PASS
- 65.14 Configure switches in ONOS - PASS
- 65.15 Check whether the flow count is bigger than 28 - FAIL Flow count looks wrong; found 17, expecting at least 28
- PASS
- 65.16 Check whether all flow status are ADDED - PASS
- 65.17 Check whether the flow count of device device:bmv2:leaf1 is bigger than 28 - FAIL Flow count looks wrong: 17
- PASS
- 65.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE65 - PASS
- 65.19 Stopping Mininet - PASS
- 65.20 Copying karaf logs - PASS
...