Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

HTML
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric3/lastSuccessfulBuild/artifact/SROnosFailure_onos-2.2_20-builds_graph.jpg", alt="SROnosFailure", style="width:525px;height:350px;border:0">

commit 18ad45bfc79f02d01226a47a7367d850a06335eb 4027cac71993e8696091a9b3ca75ffe8df5a8e16 (HEAD -] onos-2.2, origin/onos-2.2)
Author: ONOS Jenkins User [jenkins@onlab.usYi Tseng [yi@opennetworking.org]
AuthorDate: Fri Tue Oct 16 0713 19:2715:30 12 2020 +0000-0700
Commit: ONOS Jenkins User [jenkins@onlab.usYi Tseng [yi@opennetworking.org]
CommitDate: Fri Oct 16 23 08:07:27:30 50 2020 +0000
Starting snapshot 2.2.7-SNAPSHOT
Support install IntIntents to device with postcard mode

Case 1: ONOS Failure test with 2x2 Leaf-spine - PASS

...

  • 1.1 Constructing test variables - PASS (tick)
  • 1.2 Apply cell to environment - PASS (tick)
  • 1.3 Uninstalling Atomix - PASS (tick)
  • 1.4 Uninstalling ONOS package - PASS (tick)
  • 1.5 Creating ONOS package - PASS (tick)
  • 1.6 Installing Atomix - PASS (tick)
  • 1.7 Installing ONOS package - PASS (tick)
  • 1.8 Set up ONOS secure SSH - PASS (tick)
  • 1.9 Checking ONOS service - PASS (tick)
  • 1.10 Starting ONOS CLI sessions - PASS (tick)
  • 1.11 Checking ONOS nodes - PASS (tick)
  • 1.12 Checking ONOS applications - PASS (tick)
  • 1.13 Set logging levels - PASS (tick)
  • 1.14 Set ONOS configurations - PASS (tick)
  • 1.15 Starting Mininet Topology - PASS (tick)
  • 1.16 Check whether the flow count is bigger than 116 - PASS (tick)
  • 1.17 Check whether all flow status are ADDED - PASS (tick)
  • 1.18 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1 - PASS (tick)
  • 1.19 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1 - PASS (tick)
  • 1.20 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1 - PASS (tick)
  • 1.21 Killing ONOS instances with index(es): [0] - PASS (tick)
  • 1.22 Check number of topology elements - PASS (tick)
  • 1.23 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_Failure - PASS (tick)
  • 1.24 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_Failure - PASS (tick)
  • 1.25 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_Failure - PASS (tick)
  • 1.26 Recovering ONOS instances with index(es): [0] - PASS (tick)
  • 1.27 Checking if ONOS CLI is ready - PASS (tick)
  • 1.28 Checking ONOS nodes - PASS (tick)
  • 1.29 Check number of topology elements - PASS (tick)
  • 1.30 Check whether the flow count is bigger than 116 - PASS (tick)
  • 1.31 Check whether all flow status are ADDED - PASS (tick)
  • 1.32 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_Recovery - PASS (tick)
  • 1.33 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_Recovery - PASS (tick)
  • 1.34 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_Recovery - PASS (tick)
  • 1.35 Stopping Mininet - PASS (tick)
  • 1.36 Copying karaf logs - PASS (tick)

Case 2: ONOS Failure test with 4x4 Leaf-spine -

...

PASS

  • 2.1 Apply cell to environment - PASS (tick)
  • 2.2 Uninstalling Atomix - PASS (tick)
  • 2.3 Uninstalling ONOS package - PASS (tick)
  • 2.4 Creating ONOS package - PASS (tick)
  • 2.5 Installing Atomix - PASS (tick)
  • 2.6 Installing ONOS package - PASS (tick)
  • 2.7 Set up ONOS secure SSH - PASS (tick)
  • 2.8 Checking ONOS service - PASS (tick)
  • 2.9 Starting ONOS CLI sessions - PASS (tick)
  • 2.10 Checking ONOS nodes - PASS (tick)
  • 2.11 Checking ONOS applications - PASS (tick)
  • 2.12 Set logging levels - PASS (tick)
  • 2.13 Set ONOS configurations - PASS (tick)
  • 2.14 Starting Mininet Topology - PASS (tick)
  • 2.15 Check whether the flow count is bigger than 350 - PASS (tick)
  • 2.16 Check whether all flow status are ADDED - PASS (tick)
  • 2.17 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE2 - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 2.18 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2 - PASS (tick)
  • 2.19 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2 - PASS (tick)
  • 2.20 Killing ONOS instances with index(es): [0] - PASS (tick)
  • 2.21 Check number of topology elements - PASS (tick)
  • 2.22 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE2_Failure - FAIL (error)
    • IP connectivity failed
  • PASS (tick)
  • 2.23 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2_Failure - PASS (tick)
  • 2.24 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2_Failure - PASS (tick)
  • 2.25 Recovering ONOS instances with index(es): [0] - PASS (tick)
  • 2.26 Checking if ONOS CLI is ready - PASS (tick)
  • 2.27 Checking ONOS nodes - PASS (tick)
  • 2.28 Check number of topology elements - PASS (tick)
  • 2.29 Check whether the flow count is bigger than 350 - PASS (tick)
  • 2.30 Check whether all flow status are ADDED - PASS (tick)
  • 2.31 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE2_Recovery - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 2.32 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2_Recovery - PASS (tick)
  • 2.33 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2_Recovery - PASS (tick)
  • 2.34 Stopping Mininet - PASS (tick)
  • 2.35 Copying karaf logs - PASS (tick)

...