Due to a ransomware attack, the wiki was reverted to a July 2022 version. . We apologize for the lack of a more recent valid backup.
...
| HTML |
|---|
<img src="https://onos-jenkins.onlab.us/job/Pipeline_postjob_VM/lastSuccessfulBuild/artifact/SRBridging_master_20-builds_graph.jpg", alt="SRBridging", style="width:525px;height:350px;border:0"> |
commit fbd9ae9cdf19dbd09745d85ae537c88bad0c4c11 b757dbc4eb5a0fa964416096a969b9bf2d993a29 (HEAD -] master, origin/master, origin/HEAD)
Author: Yuta HIGUCHI [y-higuchi@ak.jp.nec.comCarmelo Cascone [carmelo@opennetworking.org]
AuthorDate: Wed Thu Jan 24 2325 17:3953:06 17 2018 -0800
Commit: Thomas Vachuska Carmelo Cascone [tom@opennetworkingcarmelo@opennetworking.org]
CommitDate: Thu Sat Jan 25 2227 05:1750:25 23 2018 +0000
Various small fixes
Fixed double-extraction issue in spgw parser
Case 5: Copy karaf logs - PASS
...
- 16.1 Installing ONOS package - PASS
- 16.2 Set up ONOS secure SSH - PASS
- 16.3 Checking ONOS service - PASS
- 16.4 Starting ONOS CLI sessions - PASS
- 16.5 Starting Mininet Topology - PASS
- 16.6 Check whether the flow count is bigger than 74 - PASS
- 16.7 Check whether all flow status are ADDED - PASS
- 16.8 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 16.9 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 16.10 Connectivity for [u'h1', u'h2'] CASE16 - PASS
- 16.11 Stopping Mininet - PASS
- 16.12 Copying karaf logs - PASS
Case 17: Copy karaf logs -
...
FAIL
Copying the karaf logs to preserve them throughreinstalling ONOS
- 17.1 Installing ONOS package - PASS
- 17.2 Set up ONOS secure SSH - PASS
- 17.3 Checking ONOS service - PASS
- 17.4 Starting ONOS CLI sessions - PASS
- 17.5 Starting Mininet Topology - PASS
- 17.6 Check whether the flow count is bigger than 74 - PASS
- 17.7 Check whether all flow status are ADDED - PASS
- 17.8 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
FAIL
- Flow count looks wrong: 26
- 17.9 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 17.10 Connectivity for [u'h1', u'h2'] CASE17 - PASS
FAIL
- IP connectivity failed
- 17.11 Connectivity for [u'h3', u'h4'] CASE17 - PASS
- 17.12 Stopping Mininet - PASS
- 17.13 Copying karaf logs - PASS
...
- 65.1 Installing ONOS package - PASS
- 65.2 Set up ONOS secure SSH - PASS
- 65.3 Checking ONOS service - PASS
- 65.4 Starting ONOS CLI sessions - PASS
- 65.5 Starting Mininet Topology - PASS
- 65.6 Check whether the flow count is bigger than 28 - PASS
- 65.7 Check whether all flow status are ADDED - PASS
- 65.8 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS
- 65.9 Connectivity for [u'h1', u'h2'] CASE65 - PASS
- 65.10 Stopping Mininet - PASS
- 65.11 Copying karaf logs - PASS
Case 66: Copy karaf logs -
...
FAIL
Copying the karaf logs to preserve them throughreinstalling ONOS
- 66.1 Installing ONOS package - PASS
- 66.2 Set up ONOS secure SSH - PASS
- 66.3 Checking ONOS service - PASS
- 66.4 Starting ONOS CLI sessions - PASS
- 66.5 Starting Mininet Topology - PASS
- 66.6 Check whether the flow count is bigger than 74 - PASS
FAIL
- Flow count looks wrong: False
- 66.7 Check whether all flow status are ADDED - PASS
FAIL
- Flow status is wrong!
- 66.8 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
FAIL
- Flow count looks wrong: 0
- 66.9 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 66.10 Connectivity for [u'h1', u'h2'] CASE66 - PASS
- 66.11 Stopping Mininet - PASS
- 66.12 Copying karaf logs - PASS
...