Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Published from Jenkins build: https://onos-jenkins.onlab.us/job/SR_Pipeline_master/17/

...

HTML
<img src="https://onos-jenkins.onlab.us/job/Pipeline_postjob_VM/lastSuccessfulBuild/artifact/SRBridging_master_20-builds_graph.jpg", alt="SRBridging", style="width:525px;height:350px;border:0">

commit 13b16818241bf488d9e206f6e83aaf1e01c73245 d2b7c1fb6955f8f956d718fb4763682154cc4425 (HEAD -] master, origin/master, origin/HEAD)
Author: Sean Condon [sean.condon@microsemi.com]
AuthorDate: Thu Tue Jan 25 1030 09:3138:49 50 2018 +0000
Commit: Sean Condon [sean.condon@microsemi.com]
CommitDate: Sat Tue Jan 27 1130 09:1638:26 50 2018 +0000
Add support for RESTCONF standard errors
Fixing Maven pom for drivers/microsemi

Case 5: Copy karaf logs -

...

PASS

Copying the karaf logs to preserve them throughreinstalling ONOS

  • 5.1 Constructing test variables - No Result (warning)
  • 5.2 Constructing test variables - PASS (tick)
  • 5.3 Apply cell to environment - PASS (tick)
  • 5.4 Uninstalling ONOS package - PASS (tick)
  • 5.5 Creating ONOS package - PASS (tick)
  • 5.6 Installing ONOS package - PASS (tick)
  • 5.7 Set up ONOS secure SSH - PASS (tick)
  • 5.8 Checking ONOS service - PASS (tick)
  • 5.9 Starting ONOS CLI sessions - PASS (tick)
  • 5.10 Starting Mininet Topology - PASS (tick)
  • 5.11 Check whether the flow count is bigger than 28 - PASS (tick)
  • 5.12 Check whether all flow status are ADDED - PASS (tick)
  • 5.13 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS (tick)
  • 5.14 Connectivity for [u'h1', u'h2'] CASE05 - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 5.15 Stopping Mininet - PASS (tick)
  • 5.16 Copying karaf logs - PASS (tick)

Case 6: Copy karaf logs -

...

FAIL

Copying the karaf logs to preserve them throughreinstalling ONOS

  • 6.1 Installing ONOS package - PASS (tick)
  • 6.2 Set up ONOS secure SSH - PASS (tick)
  • 6.3 Checking ONOS service - PASS (tick)
  • 6.4 Starting ONOS CLI sessions - PASS (tick)
  • 6.5 Starting Mininet Topology - PASS (tick)
  • 6.6 Check whether the flow count is bigger than 74 - PASS (tick)FAIL (error)
    • Flow count looks wrong: False
  • 6.7 Check whether all flow status are ADDED - PASS (tick)FAIL (error)
    • Flow status is wrong!
  • 6.8 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 6.9 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)FAIL (error)
    • Flow count looks wrong: 0
  • 6.10 Connectivity for [u'h1', u'h2'] CASE06 - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 6.11 Stopping Mininet - PASS (tick)
  • 6.12 Copying karaf logs - PASS (tick)

...

  • 35.1 Installing ONOS package - PASS (tick)
  • 35.2 Set up ONOS secure SSH - PASS (tick)
  • 35.3 Checking ONOS service - PASS (tick)
  • 35.4 Starting ONOS CLI sessions - PASS (tick)
  • 35.5 Starting Mininet Topology - PASS (tick)
  • 35.6 Check whether the flow count is bigger than 28 - PASS (tick)
  • 35.7 Check whether all flow status are ADDED - PASS (tick)
  • 35.8 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS (tick)
  • 35.9 Connectivity for [u'h1', u'h2'] CASE35 - PASS (tick)
  • 35.10 Stopping Mininet - PASS (tick)
  • 35.11 Copying karaf logs - PASS (tick)

Case 36: Copy karaf logs -

...

PASS

Copying the karaf logs to preserve them throughreinstalling ONOS

  • 36.1 Installing ONOS package - PASS (tick)
  • 36.2 Set up ONOS secure SSH - PASS (tick)
  • 36.3 Checking ONOS service - PASS (tick)
  • 36.4 Starting ONOS CLI sessions - PASS (tick)
  • 36.5 Starting Mininet Topology - PASS (tick)
  • 36.6 Check whether the flow count is bigger than 74 - FAIL (error)
    • Flow count looks wrong: False
  • PASS (tick)
  • 36.7 Check whether all flow status are ADDED - PASS (tick)
  • 36.8 Check whether the flow count of device of:0000000000000001 is bigger than 37 - FAIL (error)
    • Flow count looks wrong: 12
  • PASS (tick)
  • 36.9 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 36.10 Connectivity for [u'h1', u'h2'] CASE36 - FAIL (error)
    • IP connectivity failed
  • PASS (tick)
  • 36.11 Stopping Mininet - PASS (tick)
  • 36.12 Copying karaf logs - PASS (tick)

...

  • 76.1 Installing ONOS package - PASS (tick)
  • 76.2 Set up ONOS secure SSH - PASS (tick)
  • 76.3 Checking ONOS service - PASS (tick)
  • 76.4 Starting ONOS CLI sessions - PASS (tick)
  • 76.5 Starting Mininet Topology - PASS (tick)
  • 76.6 Check whether the flow count is bigger than 74 - PASS (tick)
  • 76.7 Check whether all flow status are ADDED - PASS (tick)
  • 76.8 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 76.9 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 76.10 Connectivity for [u'h1', u'h2'] CASE76 - PASS (tick)
  • 76.11 Stopping Mininet - PASS (tick)
  • 76.12 Copying karaf logs - PASS (tick)

Case 77: Copy karaf logs -

...

PASS

Copying the karaf logs to preserve them throughreinstalling ONOS

  • 77.1 Installing ONOS package - PASS (tick)
  • 77.2 Set up ONOS secure SSH - PASS (tick)
  • 77.3 Checking ONOS service - PASS (tick)
  • 77.4 Starting ONOS CLI sessions - PASS (tick)
  • 77.5 Starting Mininet Topology - PASS (tick)
  • 77.6 Check whether the flow count is bigger than 74 - PASS (tick)
  • 77.7 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • PASS (tick)
  • 77.8 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 77.9 Check whether the flow count of device of:0000000000000002 is bigger than 37 - FAIL (error)
  • Flow count looks wrong: 0
  • PASS (tick)
  • 77.10 Connectivity for [u'h1', u'h2'] CASE77 - PASS (tick)
  • 77.11 Connectivity for [u'h3', u'h4'] CASE77 - PASS (tick)
  • 77.12 Stopping Mininet - PASS (tick)
  • 77.13 Copying karaf logs - PASS (tick)

Case 78: Copy karaf logs -

...

FAIL

Copying the karaf logs to preserve them throughreinstalling ONOS

  • 78.1 Installing ONOS package - PASS (tick)
  • 78.2 Set up ONOS secure SSH - PASS (tick)
  • 78.3 Checking ONOS service - PASS (tick)
  • 78.4 Starting ONOS CLI sessions - PASS (tick)
  • 78.5 Starting Mininet Topology - PASS (tick)
  • 78.6 Check whether the flow count is bigger than 212 - PASS (tick)
  • 78.7 Check whether all flow status are ADDED - PASS (tick)FAIL (error)
    • Flow status is wrong!
  • 78.8 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)FAIL (error)
    • Flow count looks wrong: 0
  • 78.9 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 78.10 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS (tick)
  • 78.11 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS (tick)
  • 78.12 Connectivity for [u'h1', u'h2'] CASE78 - PASS (tick)
  • 78.13 Connectivity for [u'h3', u'h4'] CASE78 - PASS (tick)
  • 78.14 Stopping Mininet - PASS (tick)
  • 78.15 Copying karaf logs - PASS (tick)