Due to a ransomware attack, the wiki was reverted to a July 2022 version. . We apologize for the lack of a more recent valid backup.
...
HTML |
---|
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric3/lastSuccessfulBuild/artifact/SRBridging_unexpected ONOS branchonos-2.2_20-builds_graph.jpg", alt="SRBridging", style="width:525px;height:350px;border:0"> |
commit c655b7c7c76b7b1e8f83560199621b611fbd2782 3433e31a961b0ce97cb731ceb67fcc7da0c854b5 (HEAD -] review/unknown/olt-batchonos-2.2, origin/onos-2.2)
Author: Andrea Campanella pierventre [andrea@opennetworkingpier@opennetworking.org]
AuthorDate: Fri Nov 6 21:41:01 Tue Oct 27 16:08:48 2020 +0100
Commit: Andrea Campanella [andrea@opennetworkingPier Luigi Ventre [pier@opennetworking.org]
CommitDate: Mon Nov 9 20:38:28 2020 +0100
Parallelize Stats processingThu Oct 29 10:36:07 2020 +0000
[ONOS-8123] Fix an issue related to the component properties.
Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR, ovs switches and 3 ONOS instances - PASS
...
- 7.1 Apply cell to environment - PASS
- 7.2 Uninstalling Atomix - PASS
- 7.3 Uninstalling ONOS package - PASS
- 7.4 Installing Atomix - PASS
- 7.5 Installing ONOS package - PASS
- 7.6 Set up ONOS secure SSH - PASS
- 7.7 Checking ONOS service - PASS
- 7.8 Starting ONOS CLI sessions - PASS
- 7.9 Checking ONOS nodes - PASS
- 7.10 Checking ONOS applications - PASS
- 7.11 Set logging levels - PASS
- 7.12 Set ONOS configurations - PASS
- 7.13 Starting Mininet Topology - PASS
- 7.14 Check whether the flow count is bigger than 74 - PASS
- 7.15 Check whether all flow status are ADDED - PASS FAIL
- Flow status is wrong!
- 7.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 7.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS FAIL
- Flow count looks wrong: 23
- 7.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE7 - FAIL IP connectivity failed
- PASS
- 7.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE7 - PASS FAIL
- IP connectivity failed
- 7.20 Stopping Mininet - PASS
- 7.21 Copying karaf logs - PASS
...
- 16.1 Apply cell to environment - PASS
- 16.2 Uninstalling Atomix - PASS
- 16.3 Uninstalling ONOS package - PASS
- 16.4 Installing Atomix - PASS
- 16.5 Installing ONOS package - PASS
- 16.6 Set up ONOS secure SSH - PASS
- 16.7 Checking ONOS service - PASS
- 16.8 Starting ONOS CLI sessions - PASS
- 16.9 Checking ONOS nodes - PASS
- 16.10 Checking ONOS applications - PASS
- 16.11 Set logging levels - PASS
- 16.12 Set ONOS configurations - PASS
- 16.13 Starting Mininet Topology - PASS
- 16.14 Check whether the flow count is bigger than 74 - PASS
- 16.15 Check whether all flow status are ADDED - PASS
- 16.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 16.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 16.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE16 - PASS
- 16.19 Stopping Mininet - PASS
- 16.20 Copying karaf logs - PASS
Case 17: Bridging test between two tagged hosts, with 2x2 leaf-spine topology, ovs switches and 3 ONOS instances -
...
FAIL
- 17.1 Apply cell to environment - PASS
- 17.2 Uninstalling Atomix - PASS
- 17.3 Uninstalling ONOS package - PASS
- 17.4 Installing Atomix - PASS
- 17.5 Installing ONOS package - PASS
- 17.6 Set up ONOS secure SSH - PASS
- 17.7 Checking ONOS service - PASS
- 17.8 Starting ONOS CLI sessions - PASS
- 17.9 Checking ONOS nodes - PASS
- 17.10 Checking ONOS applications - PASS
- 17.11 Set logging levels - PASS
- 17.12 Set ONOS configurations - PASS
- 17.13 Starting Mininet Topology - PASS
- 17.14 Check whether the flow count is bigger than 74 - PASS
- 17.15 Check whether all flow status are ADDED - PASS
- 17.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 17.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS of:0000000000000002 is bigger than 37 - FAIL
- Flow count looks wrong: 22
- 17.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE17 - PASS
- 17.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE17 - PASS FAIL
- IP connectivity failed
- 17.20 Stopping Mininet - PASS
- 17.21 Copying karaf logs - PASS
Case 18: Bridging test between two tagged hosts, with 2x4 dual-homed leaf-spine topology, ovs switches and 3 ONOS instances -
...
FAIL
- 18.1 Apply cell to environment - PASS
- 18.2 Uninstalling Atomix - PASS
- 18.3 Uninstalling ONOS package - PASS
- 18.4 Installing Atomix - PASS
- 18.5 Installing ONOS package - PASS
- 18.6 Set up ONOS secure SSH - PASS
- 18.7 Checking ONOS service - PASS
- 18.8 Starting ONOS CLI sessions - PASS
- 18.9 Checking ONOS nodes - PASS
- 18.10 Checking ONOS applications - PASS
- 18.11 Set logging levels - PASS
- 18.12 Set ONOS configurations - PASS
- 18.13 Starting Mininet Topology - PASS
- 18.14 Check whether the flow count is bigger than 212 - PASS
- 18.15 Check whether all flow status are ADDED - PASS
- 18.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 18.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 18.18 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS
- 18.19 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS
- 18.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE18 - PASS
- 18.21 Verify full connectivity for [u'h3', u'h4'] with tag CASE18 - PASS FAIL
- IP connectivity failed
- 18.22 Stopping Mininet - PASS
- 18.23 Copying karaf logs - PASS
...
- 27.1 Apply cell to environment - PASS
- 27.2 Uninstalling Atomix - PASS
- 27.3 Uninstalling ONOS package - PASS
- 27.4 Installing Atomix - PASS
- 27.5 Installing ONOS package - PASS
- 27.6 Set up ONOS secure SSH - PASS
- 27.7 Checking ONOS service - PASS
- 27.8 Starting ONOS CLI sessions - PASS
- 27.9 Checking ONOS nodes - PASS
- 27.10 Checking ONOS applications - PASS
- 27.11 Set logging levels - PASS
- 27.12 Set ONOS configurations - PASS
- 27.13 Starting Mininet Topology - PASS
- 27.14 Check whether the flow count is bigger than 74 - PASS
- 27.15 Check whether all flow status are ADDED - PASS
- 27.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 27.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 27.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE27 - PASS
- 27.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE27 - PASS
- 27.20 Stopping Mininet - PASS
- 27.21 Copying karaf logs - PASS
Case 28: Bridging test between two untagged hosts on vlan-native port, with 2x4 dual-homed leaf-spine topology, ovs switches and 3 ONOS instances -
...
FAIL
- 28.1 Apply cell to environment - PASS
- 28.2 Uninstalling Atomix - PASS
- 28.3 Uninstalling ONOS package - PASS
- 28.4 Installing Atomix - PASS
- 28.5 Installing ONOS package - PASS
- 28.6 Set up ONOS secure SSH - PASS
- 28.7 Checking ONOS service - PASS
- 28.8 Starting ONOS CLI sessions - PASS
- 28.9 Checking ONOS nodes - PASS
- 28.10 Checking ONOS applications - PASS
- 28.11 Set logging levels - PASS
- 28.12 Set ONOS configurations - PASS
- 28.13 Starting Mininet Topology - PASS
- 28.14 Check whether the flow count is bigger than 212 - PASS
- 28.15 Check whether all flow status are ADDED - PASS
- 28.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 28.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 28.18 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS
- 28.19 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS
- 28.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE28 - PASS
- 28.21 Verify full connectivity for [u'h3', u'h4'] with tag CASE28 - PASS FAIL
- IP connectivity failed
- 28.22 Stopping Mininet - PASS
- 28.23 Copying karaf logs - PASS
...
- 35.1 Apply cell to environment - PASS
- 35.2 Uninstalling Atomix - PASS
- 35.3 Uninstalling ONOS package - PASS
- 35.4 Installing Atomix - PASS
- 35.5 Installing ONOS package - PASS
- 35.6 Set up ONOS secure SSH - PASS
- 35.7 Checking ONOS service - PASS
- 35.8 Starting ONOS CLI sessions - PASS
- 35.9 Checking ONOS nodes - PASS
- 35.10 Checking ONOS applications - PASS
- 35.11 Set logging levels - PASS
- 35.12 Set ONOS configurations - PASS
- 35.13 Starting Mininet Topology - PASS
- 35.14 Check whether the flow count is bigger than 28 - PASS
- 35.15 Check whether all flow status are ADDED - PASS
- 35.16 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS
- 35.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE35 - PASS
- 35.18 Stopping Mininet - PASS
- 35.19 Copying karaf logs - PASS
Case 36: Bridging test between two untagged hosts, one on vlan-untagged port and the other on vlan-native port, with dual-homed ToR, ovs switches and 3 ONOS instances -
...
PASS
- 36.1 Apply cell to environment - PASS
- 36.2 Uninstalling Atomix - PASS
- 36.3 Uninstalling ONOS package - PASS
- 36.4 Installing Atomix - PASS
- 36.5 Installing ONOS package - PASS
- 36.6 Set up ONOS secure SSH - PASS
- 36.7 Checking ONOS service - PASS
- 36.8 Starting ONOS CLI sessions - PASS
- 36.9 Checking ONOS nodes - PASS
- 36.10 Checking ONOS applications - PASS
- 36.11 Set logging levels - PASS
- 36.12 Set ONOS configurations - PASS
- 36.13 Starting Mininet Topology - PASS
- 36.14 Check whether the flow count is bigger than 74 - PASS
- 36.15 Check whether all flow status are ADDED - PASS
- 36.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 36.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 36.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE36 - FAIL IP connectivity failed
- PASS
- 36.19 Stopping Mininet - PASS
- 36.20 Copying karaf logs - PASS
Case 37: Bridging test between two untagged hosts, one on vlan-untagged port and the other on vlan-native port, with 2x2 leaf-spine topology, ovs switches and 3 ONOS instances -
...
PASS
- 37.1 Apply cell to environment - PASS
- 37.2 Uninstalling Atomix - PASS
- 37.3 Uninstalling ONOS package - PASS
- 37.4 Installing Atomix - PASS
- 37.5 Installing ONOS package - PASS
- 37.6 Set up ONOS secure SSH - PASS
- 37.7 Checking ONOS service - PASS
- 37.8 Starting ONOS CLI sessions - PASS
- 37.9 Checking ONOS nodes - PASS
- 37.10 Checking ONOS applications - PASS
- 37.11 Set logging levels - PASS
- 37.12 Set ONOS configurations - PASS
- 37.13 Starting Mininet Topology - PASS
- 37.14 Check whether the flow count is bigger than 74 - PASS
- 37.15 Check whether all flow status are ADDED - PASS
- 37.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 37.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 37.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE37 - FAIL
- IP connectivity failed
- PASS
- 37.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE37 - PASS
- 37.20 Stopping Mininet - PASS
- 37.21 Copying karaf logs - PASS
Case 38: Bridging test between two untagged hosts, one on vlan-untagged port and the other on vlan-native port, with 2x4 dual-homed leaf-spine topology, ovs switches and 3 ONOS instances -
...
FAIL
- 38.1 Apply cell to environment - PASS
- 38.2 Uninstalling Atomix - PASS
- 38.3 Uninstalling ONOS package - PASS
- 38.4 Installing Atomix - PASS
- 38.5 Installing ONOS package - PASS
- 38.6 Set up ONOS secure SSH - PASS
- 38.7 Checking ONOS service - PASS
- 38.8 Starting ONOS CLI sessions - PASS
- 38.9 Checking ONOS nodes - PASS
- 38.10 Checking ONOS applications - PASS
- 38.11 Set logging levels - PASS
- 38.12 Set ONOS configurations - PASS
- 38.13 Starting Mininet Topology - PASS
- 38.14 Check whether the flow count is bigger than 212 - PASS
- 38.15 Check whether all flow status are ADDED - PASS
- 38.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 38.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 38.18 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS
- 38.19 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS
- 38.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE38 - PASS
- 38.21 Verify full connectivity for [u'h3', u'h4'] with tag CASE38 - PASS FAIL
- IP connectivity failed
- 38.22 Stopping Mininet - PASS
- 38.23 Copying karaf logs - PASS
...
- 48.1 Apply cell to environment - PASS
- 48.2 Uninstalling Atomix - PASS
- 48.3 Uninstalling ONOS package - PASS
- 48.4 Installing Atomix - PASS
- 48.5 Installing ONOS package - PASS
- 48.6 Set up ONOS secure SSH - PASS
- 48.7 Checking ONOS service - PASS
- 48.8 Starting ONOS CLI sessions - PASS
- 48.9 Checking ONOS nodes - PASS
- 48.10 Checking ONOS applications - PASS
- 48.11 Set logging levels - PASS
- 48.12 Set ONOS configurations - PASS
- 48.13 Starting Mininet Topology - PASS
- 48.14 Check whether the flow count is bigger than 212 - PASS
- 48.15 Check whether all flow status are ADDED - PASS
- 48.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 48.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 48.18 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS
- 48.19 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS
- 48.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE48 - PASS
- 48.21 Verify full connectivity for [u'h3', u'h4'] with tag CASE48 - PASS
- 48.22 Stopping Mininet - PASS
- 48.23 Copying karaf logs - PASS
Case 55: Bridging test between two untagged hosts with different vlan id, with single ToR, ovs switches and 3 ONOS instances -
...
FAIL
- 55.1 Apply cell to environment - PASS
- 55.2 Uninstalling Atomix - PASS
- 55.3 Uninstalling ONOS package - PASS
- 55.4 Installing Atomix - PASS
- 55.5 Installing ONOS package - PASS
- 55.6 Set up ONOS secure SSH - PASS
- 55.7 Checking ONOS service - PASS
- 55.8 Starting ONOS CLI sessions - PASS
- 55.9 Checking ONOS nodes - PASS
- 55.10 Checking ONOS applications - PASS
- 55.11 Set logging levels - PASS
- 55.12 Set ONOS configurations - PASS
- 55.13 Starting Mininet Topology - PASS
- 55.14 Check whether the flow count is bigger than 28 - PASS FAIL
- Flow count looks wrong; found 21, expecting at least 28
- 55.15 Check whether all flow status are ADDED - PASS
- 55.16 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS FAIL
- Flow count looks wrong: 21
- 55.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE55 - PASS
- 55.18 Stopping Mininet - PASS
- 55.19 Copying karaf logs - PASS
...