Due to a ransomware attack, the wiki was reverted to a July 2022 version. . We apologize for the lack of a more recent valid backup.
...
HTML |
---|
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric3/lastSuccessfulBuild/artifact/SRBridging-stratum_onos-2.2_20-builds_graph.jpg", alt="SRBridging-stratum", style="width:525px;height:350px;border:0"> |
commit 3433e31a961b0ce97cb731ceb67fcc7da0c854b5 dad65ac5a058242326fe91fbe47e65fa9c5a3583 (HEAD -] onos-2.2, origin/onos-2.2)
Author: pierventre Andrea Campanella [pier@opennetworkingandrea@opennetworking.org]
AuthorDate: Tue Oct 27 16:08:48 Fri Nov 6 21:41:01 2020 +0100
Commit: Pier Luigi Ventre [pier@opennetworkingAndrea Campanella [andrea@opennetworking.org]
CommitDate: Thu Oct 29 10:36:07 2020 +0000
[ONOS-8123] Fix an issue related to the component propertiesWed Nov 11 19:35:09 2020 +0100
Offload OF Port Status message processing to a single thread executor.
Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR, stratum switches and 3 ONOS instances - PASS
...
- 56.1 Apply cell to environment - PASS
- 56.2 Uninstalling Atomix - PASS
- 56.3 Uninstalling ONOS package - PASS
- 56.4 Create Cluster Config - PASS
- 56.5 Installing Atomix via docker containers - PASS
- 56.6 Installing ONOS via docker containers - PASS
- 56.7 Set up ONOS secure SSH - PASS
- 56.8 Starting ONOS CLI sessions - PASS
- 56.9 Checking ONOS nodes - PASS
- 56.10 Checking ONOS applications - PASS
- 56.11 Set logging levels - PASS
- 56.12 Set ONOS configurations - PASS
- 56.13 Starting Mininet Topology - PASS
- 56.14 Configure switches in ONOS - PASS
- 56.15 Check whether the flow count is bigger than 74 - PASS
- 56.16 Check whether all flow status are ADDED - PASS
- 56.17 Check whether the flow count of device device:bmv2:leaf1 is bigger than 37 - PASS
- 56.18 Check whether the flow count of device device:bmv2:leaf2 is bigger than 37 - PASS
- 56.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE56 - PASS
- 56.20 Stopping Mininet - PASS
- 56.21 Copying karaf logs - PASS
Case 57: Bridging test between two untagged hosts with different vlan id, with 2x2 leaf-spine topology, stratum switches and 3 ONOS instances -
...
PASS
- 57.1 Apply cell to environment - PASS
- 57.2 Uninstalling Atomix - PASS
- 57.3 Uninstalling ONOS package - PASS
- 57.4 Create Cluster Config - PASS
- 57.5 Installing Atomix via docker containers - PASS
- 57.6 Installing ONOS via docker containers - PASS
- 57.7 Set up ONOS secure SSH - PASS
- 57.8 Starting ONOS CLI sessions - PASS
- 57.9 Checking ONOS nodes - PASS
- 57.10 Checking ONOS applications - PASS
- 57.11 Set logging levels - PASS
- 57.12 Set ONOS configurations - PASS
- 57.13 Starting Mininet Topology - PASS
- 57.14 Configure switches in ONOS - PASS
- 57.15 Check whether the flow count is bigger than 64 - FAIL
- Flow count looks wrong; found 38, expecting at least 64
- PASS
- 57.16 Check whether all flow status are ADDED - PASS
- 57.17 Check whether the flow count of device device:bmv2:leaf1 is bigger than 32 - FAIL
- Flow count looks wrong: 3
- PASS
- 57.18 Check whether the flow count of device device:bmv2:leaf2 is bigger than 32 - FAIL Flow count looks wrong: 3
- PASS
- 57.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE57 - PASS
- 57.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE57 - PASS
- 57.21 Stopping Mininet - PASS
- 57.22 Copying karaf logs - PASS
...