Comment: Published from Jenkins build: https://jenkins.onosproject.org/job/SR-pipeline-master/69/

...

HTML
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric/lastSuccessfulBuild/artifact/SRBridging_master_20-builds_graph.jpg", alt="SRBridging", style="width:525px;height:350px;border:0">

commit 545edb4a047b0e9a6e1c15cbe3cfa2237251094c 67de597c5d2ccef246c7f564beab6064695e509c (HEAD -] master, origin/master, origin/HEAD)
Author: Andrea Campanella [andrea@opennetworking.orgPalash Kala [palash.kala@samsung.com]
AuthorDate: Tue Thu Mar 20 1622 14:3710:29 50 2018 -0700+0900
Commit: Andrea Campanella [andrea@opennetworkingYuta HIGUCHI [y-higuchi@opennetworking.org]
CommitDate: Fri Mon Mar 23 1326 04:5740:41 39 2018 -0700
Moving Multicast subsystem into app and refactoring APIs to support multihomed sources and sinks+0000

[ONOS-7554] Option in DeviceSetControllersCommand CLI to remove controllers configuration from device

Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR and 3 ONOS instances - FAIL

...

  • 6.1 Apply cell to environment - PASS (tick)
  • 6.2 Uninstalling ONOS package - PASS (tick)
  • 6.3 Installing ONOS package - PASS (tick)
  • 6.4 Set up ONOS secure SSH - PASS (tick)
  • 6.5 Checking ONOS service - PASS (tick)
  • 6.6 Starting ONOS CLI sessions - PASS (tick)
  • 6.7 Starting Mininet Topology - PASS (tick)
  • 6.8 Check whether the flow count is bigger than 74 - PASS (tick)
  • 6.9 Check whether all flow status are ADDED - PASS (tick)
  • 6.10 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 6.11 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 6.12 Verify full connectivity for [u'h1', u'h2'] with tag CASE6 - FAIL (error)
    • IP connectivity failed
  • 6.13 Stopping Mininet - PASS (tick)
  • 6.14 Copying karaf logs - PASS (tick)

Case 7: Bridging test between two untagged hosts on vlan-untagged port, with 2x2 leaf-spine topology and 3 ONOS instances -

...

PASS

  • 7.1 Apply cell to environment - PASS (tick)
  • 7.2 Uninstalling ONOS package - PASS (tick)
  • 7.3 Installing ONOS package - PASS (tick)
  • 7.4 Set up ONOS secure SSH - PASS (tick)
  • 7.5 Checking ONOS service - PASS (tick)
  • 7.6 Starting ONOS CLI sessions - PASS (tick)
  • 7.7 Starting Mininet Topology - PASS (tick)
  • 7.8 Check whether the flow count is bigger than 74 - PASS (tick)
  • 7.9 Check whether all flow status are ADDED - PASS (tick)
  • 7.10 Check whether the flow count of device of:0000000000000001 is bigger than 37 - FAIL (error)
    • Flow count looks wrong.
  • PASS (tick)
  • 7.11 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 7.12 Verify full connectivity for [u'h1', u'h2'] with tag CASE7 - FAIL (error)
    • IP connectivity failed
  • PASS (tick)
  • 7.13 Verify full connectivity for [u'h3', u'h4'] with tag CASE7 - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 7.14 Stopping Mininet - PASS (tick)
  • 7.15 Copying karaf logs - PASS (tick)

...

  • 8.1 Apply cell to environment - PASS (tick)
  • 8.2 Uninstalling ONOS package - PASS (tick)
  • 8.3 Installing ONOS package - PASS (tick)
  • 8.4 Set up ONOS secure SSH - PASS (tick)
  • 8.5 Checking ONOS service - PASS (tick)
  • 8.6 Starting ONOS CLI sessions - PASS (tick)
  • 8.7 Starting Mininet Topology - PASS (tick)
  • 8.8 Check whether the flow count is bigger than 212 - PASS (tick)
  • 8.9 Check whether all flow status are ADDED - PASS (tick)
  • 8.10 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 8.11 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 8.12 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS (tick)
  • 8.13 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS (tick)than 53 - FAIL (error)
    • Flow count looks wrong.
  • 8.14 Verify full connectivity for [u'h1', u'h2'] with tag CASE8 - PASS (tick)
  • 8.15 Verify full connectivity for [u'h3', u'h4'] with tag CASE8 - FAIL (error)
    • IP connectivity failed
  • 8.16 Stopping Mininet - PASS (tick)
  • 8.17 Copying karaf logs - PASS (tick)

...

  • 17.1 Apply cell to environment - PASS (tick)
  • 17.2 Uninstalling ONOS package - PASS (tick)
  • 17.3 Installing ONOS package - PASS (tick)
  • 17.4 Set up ONOS secure SSH - PASS (tick)
  • 17.5 Checking ONOS service - PASS (tick)
  • 17.6 Starting ONOS CLI sessions - PASS (tick)
  • 17.7 Starting Mininet Topology - PASS (tick)
  • 17.8 Check whether the flow count is bigger than 74 - PASS (tick)
  • 17.9 Check whether all flow status are ADDED - PASS (tick)
  • 17.10 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)FAIL (error)
    • Flow count looks wrong.
  • 17.11 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 17.12 Verify full connectivity for [u'h1', u'h2'] with tag CASE17 - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 17.13 Verify full connectivity for [u'h3', u'h4'] with tag CASE17 - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 17.14 Stopping Mininet - PASS (tick)
  • 17.15 Copying karaf logs - PASS (tick)

...

  • 18.1 Apply cell to environment - PASS (tick)
  • 18.2 Uninstalling ONOS package - PASS (tick)
  • 18.3 Installing ONOS package - PASS (tick)
  • 18.4 Set up ONOS secure SSH - PASS (tick)
  • 18.5 Checking ONOS service - PASS (tick)
  • 18.6 Starting ONOS CLI sessions - PASS (tick)
  • 18.7 Starting Mininet Topology - PASS (tick)
  • 18.8 Check whether the flow count is bigger than 212 - PASS (tick)
  • 18.9 Check whether all flow status are ADDED - PASS (tick)
  • 18.10 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)FAIL (error)
    • Flow count looks wrong.
  • 18.11 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)FAIL (error)
    • Flow count looks wrong.
  • 18.12 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS (tick)
  • 18.13 Check whether the flow count of device of:0000000000000004 is bigger than 53 - FAIL (error)
    • Flow count looks wrong.
  • PASS (tick)
  • 18.14 Verify full connectivity for [u'h1', u'h2'] with tag CASE18 - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 18.15 Verify full connectivity for [u'h3', u'h4'] with tag CASE18 - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 18.16 Stopping Mininet - PASS (tick)
  • 18.17 Copying karaf logs - PASS (tick)

...

  • 28.1 Apply cell to environment - PASS (tick)
  • 28.2 Uninstalling ONOS package - PASS (tick)
  • 28.3 Installing ONOS package - PASS (tick)
  • 28.4 Set up ONOS secure SSH - PASS (tick)
  • 28.5 Checking ONOS service - PASS (tick)
  • 28.6 Starting ONOS CLI sessions - PASS (tick)
  • 28.7 Starting Mininet Topology - PASS (tick)
  • 28.8 Check whether the flow count is bigger than 212 - PASS (tick)
  • 28.9 Check whether all flow status are ADDED - PASS (tick)
  • 28.10 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 28.11 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)FAIL (error)
    • Flow count looks wrong.
  • 28.12 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS (tick)
  • 28.13 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS (tick)
  • 28.14 Verify full connectivity for [u'h1', u'h2'] with tag CASE28 - FAIL (error)
    • IP connectivity failed
  • 28.15 Verify full connectivity for [u'h3', u'h4'] with tag CASE28 - FAIL (error)
    • IP connectivity failed
  • 28.16 Stopping Mininet - PASS (tick)
  • 28.17 Copying karaf logs - PASS (tick)

...

  • 36.1 Apply cell to environment - PASS (tick)
  • 36.2 Uninstalling ONOS package - PASS (tick)
  • 36.3 Installing ONOS package - PASS (tick)
  • 36.4 Set up ONOS secure SSH - PASS (tick)
  • 36.5 Checking ONOS service - PASS (tick)
  • 36.6 Starting ONOS CLI sessions - PASS (tick)
  • 36.7 Starting Mininet Topology - PASS (tick)
  • 36.8 Check whether the flow count is bigger than 74 - PASS (tick)
  • 36.9 Check whether all flow status are ADDED - PASS (tick)
  • 36.10 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 36.11 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 36.12 Verify full connectivity for [u'h1', u'h2'] with tag CASE36 - FAIL (error)
    • IP connectivity failed
  • 36.13 Stopping Mininet - PASS (tick)
  • 36.14 Copying karaf logs - PASS (tick)

Case 37: Bridging test between two untagged hosts, one on vlan-untagged port and the other on vlan-native port, with 2x2 leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 37.1 Apply cell to environment - PASS (tick)
  • 37.2 Uninstalling ONOS package - PASS (tick)
  • 37.3 Installing ONOS package - PASS (tick)
  • 37.4 Set up ONOS secure SSH - PASS (tick)
  • 37.5 Checking ONOS service - PASS (tick)
  • 37.6 Starting ONOS CLI sessions - PASS (tick)
  • 37.7 Starting Mininet Topology - PASS (tick)
  • 37.8 Check whether the flow count is bigger than 74 - PASS (tick)
  • 37.9 Check whether all flow status are ADDED - PASS (tick)
  • 37.10 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)FAIL (error)
    • Flow count looks wrong.
  • 37.11 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 37.12 Verify full connectivity for [u'h1', u'h2'] with tag CASE37 - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 37.13 Verify full connectivity for [u'h3', u'h4'] with tag CASE37 - PASS (tick)
  • 37.14 Stopping Mininet - PASS (tick)
  • 37.15 Copying karaf logs - PASS (tick)

...

  • 38.1 Apply cell to environment - PASS (tick)
  • 38.2 Uninstalling ONOS package - PASS (tick)
  • 38.3 Installing ONOS package - PASS (tick)
  • 38.4 Set up ONOS secure SSH - PASS (tick)
  • 38.5 Checking ONOS service - PASS (tick)
  • 38.6 Starting ONOS CLI sessions - PASS (tick)
  • 38.7 Starting Mininet Topology - PASS (tick)
  • 38.8 Check whether the flow count is bigger than 212 - PASS (tick)
  • 38.9 Check whether all flow status are ADDED - PASS (tick)
  • 38.10 Check whether the flow count of device of:0000000000000001 is bigger than 53 - FAIL (error)
  • Flow count looks wrong.
  • PASS (tick)
  • 38.11 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)FAIL (error)
    • Flow count looks wrong.
  • 38.12 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS (tick)
  • 38.13 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS (tick)
  • 38.14 Verify full connectivity for [u'h1', u'h2'] with tag CASE38 - FAIL (error)
    • IP connectivity failed
  • 38.15 Verify full connectivity for [u'h3', u'h4'] with tag CASE38 - PASS (tick)
  • 38.16 Stopping Mininet - PASS (tick)
  • 38.17 Copying karaf logs - PASS (tick)

...

  • 47.1 Apply cell to environment - PASS (tick)
  • 47.2 Uninstalling ONOS package - PASS (tick)
  • 47.3 Installing ONOS package - PASS (tick)
  • 47.4 Set up ONOS secure SSH - PASS (tick)
  • 47.5 Checking ONOS service - PASS (tick)
  • 47.6 Starting ONOS CLI sessions - PASS (tick)
  • 47.7 Starting Mininet Topology - PASS (tick)
  • 47.8 Check whether the flow count is bigger than 74 - PASS (tick)
  • 47.9 Check whether all flow status are ADDED - PASS (tick)
  • 47.10 Check whether the flow count of device of:0000000000000001 is bigger than 37 - FAIL (error)
    • Flow count looks wrong.
  • PASS (tick)
  • 47.11 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 47.12 Verify full connectivity for [u'h1', u'h2'] with tag CASE47 - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 47.13 Verify full connectivity for [u'h3', u'h4'] with tag CASE47 - FAIL (error)
    • IP connectivity failed
  • 47.14 Stopping Mininet - PASS (tick)
  • 47.15 Copying karaf logs - PASS (tick)

...

  • 48.1 Apply cell to environment - PASS (tick)
  • 48.2 Uninstalling ONOS package - PASS (tick)
  • 48.3 Installing ONOS package - PASS (tick)
  • 48.4 Set up ONOS secure SSH - PASS (tick)
  • 48.5 Checking ONOS service - PASS (tick)
  • 48.6 Starting ONOS CLI sessions - PASS (tick)
  • 48.7 Starting Mininet Topology - PASS (tick)
  • 48.8 Check whether the flow count is bigger than 212 - PASS (tick)
  • 48.9 Check whether all flow status are ADDED - PASS (tick)
  • 48.10 Check whether the flow count of device of:0000000000000001 is bigger than 53 - FAIL (error)
  • Flow count looks wrong.
  • PASS (tick)
  • 48.11 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)FAIL (error)
    • Flow count looks wrong.
  • 48.12 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS (tick)
  • 48.13 Check whether the flow count of device of:0000000000000004 is bigger than 53 - FAIL (error)
  • Flow count looks wrong.
  • PASS (tick)
  • 48.14 Verify full connectivity for [u'h1', u'h2'] with tag CASE48 - FAIL (error)
    • IP connectivity failed
  • 48.15 Verify full connectivity for [u'h3', u'h4'] with tag CASE48 - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 48.16 Stopping Mininet - PASS (tick)
  • 48.17 Copying karaf logs - PASS (tick)

...

  • 57.1 Apply cell to environment - PASS (tick)
  • 57.2 Uninstalling ONOS package - PASS (tick)
  • 57.3 Installing ONOS package - PASS (tick)
  • 57.4 Set up ONOS secure SSH - PASS (tick)
  • 57.5 Checking ONOS service - PASS (tick)
  • 57.6 Starting ONOS CLI sessions - PASS (tick)
  • 57.7 Starting Mininet Topology - PASS (tick)
  • 57.8 Check whether the flow count is bigger than 74 - PASS (tick)
  • 57.9 Check whether all flow status are ADDED - PASS (tick)
  • 57.10 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 57.11 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 57.12 Verify full connectivity for [u'h1', u'h2'] with tag CASE57 - PASS (tick)
  • 57.13 Verify full connectivity for [u'h3', u'h4'] with tag CASE57 - PASS (tick)
  • 57.14 Stopping Mininet - PASS (tick)
  • 57.15 Copying karaf logs - PASS (tick)

Case 58: Bridging test between two untagged hosts with different vlan id, with 2x4 dual-homed leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 58.1 Apply cell to environment - PASS (tick)
  • 58.2 Uninstalling ONOS package - PASS (tick)
  • 58.3 Installing ONOS package - PASS (tick)
  • 58.4 Set up ONOS secure SSH - PASS (tick)
  • 58.5 Checking ONOS service - PASS (tick)
  • 58.6 Starting ONOS CLI sessions - PASS (tick)
  • 58.7 Starting Mininet Topology - PASS (tick)
  • 58.8 Check whether the flow count is bigger than 212 - PASS (tick)
  • 58.9 Check whether all flow status are ADDED - PASS (tick)
  • 58.10 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)FAIL (error)
    • Flow count looks wrong.
  • 58.11 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 58.12 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS (tick)
  • 58.13 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS (tick)
  • 58.14 Verify full connectivity for [u'h1', u'h2'] with tag CASE58 - PASS (tick)
  • 58.15 Verify full connectivity for [u'h3', u'h4'] with tag CASE58 - PASS (tick)
  • 58.16 Stopping Mininet - PASS (tick)
  • 58.17 Copying karaf logs - PASS (tick)

...

  • 68.1 Apply cell to environment - PASS (tick)
  • 68.2 Uninstalling ONOS package - PASS (tick)
  • 68.3 Installing ONOS package - PASS (tick)
  • 68.4 Set up ONOS secure SSH - PASS (tick)
  • 68.5 Checking ONOS service - PASS (tick)
  • 68.6 Starting ONOS CLI sessions - PASS (tick)
  • 68.7 Starting Mininet Topology - PASS (tick)
  • 68.8 Check whether the flow count is bigger than 212 - PASS (tick)
  • 68.9 Check whether all flow status are ADDED - PASS (tick)
  • 68.10 Check whether the flow count of device of:0000000000000001 is bigger than 53 - FAIL (error)
  • Flow count looks wrong.
  • PASS (tick)
  • 68.11 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)FAIL (error)
    • Flow count looks wrong.
  • 68.12 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS (tick)
  • 68.13 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS (tick)
  • 68.14 Verify full connectivity for [u'h1', u'h2'] with tag CASE68 - PASS (tick)
  • 68.15 Verify full connectivity for [u'h3', u'h4'] with tag CASE68 - PASS (tick)
  • 68.16 Stopping Mininet - PASS (tick)
  • 68.17 Copying karaf logs - PASS (tick)

...

  • 76.1 Apply cell to environment - PASS (tick)
  • 76.2 Uninstalling ONOS package - PASS (tick)
  • 76.3 Installing ONOS package - PASS (tick)
  • 76.4 Set up ONOS secure SSH - PASS (tick)
  • 76.5 Checking ONOS service - PASS (tick)
  • 76.6 Starting ONOS CLI sessions - PASS (tick)
  • 76.7 Starting Mininet Topology - PASS (tick)
  • 76.8 Check whether the flow count is bigger than 74 - PASS (tick)
  • 76.9 Check whether all flow status are ADDED - PASS (tick)
  • 76.10 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 76.11 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 76.12 Verify full connectivity for [u'h1', u'h2'] with tag CASE76 - PASS (tick)
  • 76.13 Stopping Mininet - PASS (tick)
  • 76.14 Copying karaf logs - PASS (tick)

Case 77: Bridging test between untagged and tagged hosts with different vlan id, with 2x2 leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 77.1 Apply cell to environment - PASS (tick)
  • 77.2 Uninstalling ONOS package - PASS (tick)
  • 77.3 Installing ONOS package - PASS (tick)
  • 77.4 Set up ONOS secure SSH - PASS (tick)
  • 77.5 Checking ONOS service - PASS (tick)
  • 77.6 Starting ONOS CLI sessions - PASS (tick)
  • 77.7 Starting Mininet Topology - PASS (tick)
  • 77.8 Check whether the flow count is bigger than 74 - PASS (tick)FAIL (error)
    • Flow count looks wrong: False
  • 77.9 Check whether all flow status are ADDED - PASS (tick)
  • 77.10 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)FAIL (error)
    • Flow count looks wrong.
  • 77.11 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)FAIL (error)
    • Flow count looks wrong.
  • 77.12 Verify full connectivity for [u'h1', u'h2'] with tag CASE77 - PASS (tick)
  • 77.13 Verify full connectivity for [u'h3', u'h4'] with tag CASE77 - PASS (tick)
  • 77.14 Stopping Mininet - PASS (tick)
  • 77.15 Copying karaf logs - PASS (tick)

Case 78: Bridging test between untagged and tagged hosts with different vlan id, with 2x4 dual-homed leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 78.1 Apply cell to environment - PASS (tick)
  • 78.2 Uninstalling ONOS package - PASS (tick)
  • 78.3 Installing ONOS package - PASS (tick)
  • 78.4 Set up ONOS secure SSH - PASS (tick)
  • 78.5 Checking ONOS service - PASS (tick)
  • 78.6 Starting ONOS CLI sessions - PASS (tick)
  • 78.7 Starting Mininet Topology - PASS (tick)
  • 78.8 Check whether the flow count is bigger than 212 - PASS (tick)
  • 78.9 Check whether all flow status are ADDED - PASS (tick)
  • 78.10 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 78.11 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 78.12 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS (tick)
  • 78.13 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS (tick)FAIL (error)
    • Flow count looks wrong.
  • 78.14 Verify full connectivity for [u'h1', u'h2'] with tag CASE78 - PASS (tick)
  • 78.15 Verify full connectivity for [u'h3', u'h4'] with tag CASE78 - PASS (tick)
  • 78.16 Stopping Mininet - PASS (tick)
  • 78.17 Copying karaf logs - PASS (tick)