Due to a ransomware attack, the wiki was reverted to a July 2022 version. . We apologize for the lack of a more recent valid backup.
...
| HTML |
|---|
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric2/lastSuccessfulBuild/artifact/SRBridging_master_20-builds_graph.jpg", alt="SRBridging", style="width:525px;height:350px;border:0"> |
commit d5c229667c1a96495e939e2197faa79d45909977 44e3a612347d7d91abe86d9709a9790029aaa21c (HEAD -] master, origin/master, origin/HEAD)
Author: Yuta HIGUCHI [y-higuchi@ak.jp.nec.com]
AuthorDate: Fri May 11 15:0403:34 39 2018 -0700
Commit: Yuta HIGUCHI [y-higuchi@opennetworking.org]
CommitDate: Sat Mon May 12 0014 20:1411:30 41 2018 +0000
Add log when model registrators activateskey constants for ODTN
Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR and 3 ONOS instances - FAIL
...
- 18.1 Apply cell to environment - PASS
- 18.2 Uninstalling ONOS package - PASS
- 18.3 Installing ONOS package - PASS
- 18.4 Set up ONOS secure SSH - PASS
- 18.5 Checking ONOS service - PASS
- 18.6 Starting ONOS CLI sessions - PASS
- 18.7 Starting Mininet Topology - PASS
- 18.8 Check whether the flow count is bigger than 212 - PASS
- 18.9 Check whether all flow status are ADDED - PASS
- 18.10 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 18.11 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 18.12 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS
- 18.13 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS
- 18.14 Verify full connectivity for [u'h1', u'h2'] with tag CASE18 - PASS
- 18.15 Verify full connectivity for [u'h3', u'h4'] with tag CASE18 - PASS
- 18.16 Stopping Mininet - PASS
- 18.17 Copying karaf logs - PASS
Case 25: Bridging test between two untagged hosts on vlan-native port, with single ToR and 3 ONOS instances -
...
PASS
- 25.1 Apply cell to environment - PASS
- 25.2 Uninstalling ONOS package - PASS
- 25.3 Installing ONOS package - PASS
- 25.4 Set up ONOS secure SSH - PASS
- 25.5 Checking ONOS service - PASS
- 25.6 Starting ONOS CLI sessions - PASS
- 25.7 Starting Mininet Topology - PASS
- 25.8 Check whether the flow count is bigger than 28 - FAIL
- Flow count looks wrong: False
- PASS
- 25.9 Check whether all flow status are ADDED - PASS
- 25.10 Check whether the flow count of device of:0000000000000001 is bigger than 28 - FAIL
- PASS
- 25.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE25 - FAIL
- IP connectivity failed
- PASS
- 25.12 Stopping Mininet - PASS
- 25.13 Copying karaf logs - PASS
...
- 48.1 Apply cell to environment - PASS
- 48.2 Uninstalling ONOS package - PASS
- 48.3 Installing ONOS package - PASS
- 48.4 Set up ONOS secure SSH - PASS
- 48.5 Checking ONOS service - PASS
- 48.6 Starting ONOS CLI sessions - PASS
- 48.7 Starting Mininet Topology - PASS
- 48.8 Check whether the flow count is bigger than 212 - PASS
- 48.9 Check whether all flow status are ADDED - PASS
- 48.10 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 48.11 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 48.12 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS
- 48.13 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS
- 48.14 Verify full connectivity for [u'h1', u'h2'] with tag CASE48 - PASS
- 48.15 Verify full connectivity for [u'h3', u'h4'] with tag CASE48 - PASS
- 48.16 Stopping Mininet - PASS
- 48.17 Copying karaf logs - PASS
Case 55: Bridging test between two untagged hosts with different vlan id, with single ToR and 3 ONOS instances -
...
FAIL
- 55.1 Apply cell to environment - PASS
- 55.2 Uninstalling ONOS package - PASS
- 55.3 Installing ONOS package - PASS
- 55.4 Set up ONOS secure SSH - PASS
- 55.5 Checking ONOS service - PASS
- 55.6 Starting ONOS CLI sessions - PASS
- 55.7 Starting Mininet Topology - PASS
- 55.8 Check whether the flow count is bigger than 28 - PASS
FAIL
- Flow count looks wrong: False
- 55.9 Check whether all flow status are ADDED - PASS
- 55.10 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS
FAIL
- Flow count looks wrong.
- 55.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE55 - PASS
- 55.12 Stopping Mininet - PASS
- 55.13 Copying karaf logs - PASS
...