commit ec18d3a759bf7f97d880660baf8045ffa6b3bfb6 b32da8553ced8b87367bb7a43f45ebdd94dbc96a (HEAD -] master, origin/master, origin/HEAD)
Author: hiroki Ray Milkey [hirokiray@opennetworking.okui@gmail.comorg]
AuthorDate: Wed Fri May 16 18 15:2742:37 16 2018 -0700
Commit: Yuta HIGUCHI [y-higuchi@opennetworkingRay Milkey [ray@opennetworking.org]
CommitDate: Fri Tue May 18 22 02:3248:21 39 2018 +0000
Add Tapi Context/Topology/Node/Link builders and utility class
Increase Felix lock acquisition timeout

Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR and 3 ONOS instances - PASS

...

  • 48.1 Apply cell to environment - PASS (tick)
  • 48.2 Uninstalling ONOS package - PASS (tick)
  • 48.3 Installing ONOS package - PASS (tick)
  • 48.4 Set up ONOS secure SSH - PASS (tick)
  • 48.5 Checking ONOS service - PASS (tick)
  • 48.6 Starting ONOS CLI sessions - PASS (tick)
  • 48.7 Starting Mininet Topology - PASS (tick)
  • 48.8 Check whether the flow count is bigger than 212 - PASS (tick)
  • 48.9 Check whether all flow status are ADDED - PASS (tick)
  • 48.10 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 48.11 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 48.12 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS (tick)
  • 48.13 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS (tick)
  • 48.14 Verify full connectivity for [u'h1', u'h2'] with tag CASE48 - PASS (tick)
  • 48.15 Verify full connectivity for [u'h3', u'h4'] with tag CASE48 - PASS (tick)
  • 48.16 Stopping Mininet - PASS (tick)
  • 48.17 Copying karaf logs - PASS (tick)

Case 55: Bridging test between two untagged hosts with different vlan id, with single ToR and 3 ONOS instances -

...

PASS

  • 55.1 Apply cell to environment - PASS (tick)
  • 55.2 Uninstalling ONOS package - PASS (tick)
  • 55.3 Installing ONOS package - PASS (tick)
  • 55.4 Set up ONOS secure SSH - PASS (tick)
  • 55.5 Checking ONOS service - PASS (tick)
  • 55.6 Starting ONOS CLI sessions - PASS (tick)
  • 55.7 Starting Mininet Topology - PASS (tick)
  • 55.8 Check whether the flow count is bigger than 28 - FAIL (error)
  • Flow count looks wrong: False
  • PASS (tick)
  • 55.9 Check whether all flow status are ADDED - PASS (tick)
  • 55.10 Check whether the flow count of device of:0000000000000001 is bigger than 28 - FAIL (error)
  • Flow count looks wrong.
  • PASS (tick)
  • 55.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE55 - PASS (tick)
  • 55.12 Stopping Mininet - PASS (tick)
  • 55.13 Copying karaf logs - PASS (tick)

...

  • 56.1 Apply cell to environment - PASS (tick)
  • 56.2 Uninstalling ONOS package - PASS (tick)
  • 56.3 Installing ONOS package - PASS (tick)
  • 56.4 Set up ONOS secure SSH - PASS (tick)
  • 56.5 Checking ONOS service - PASS (tick)
  • 56.6 Starting ONOS CLI sessions - PASS (tick)
  • 56.7 Starting Mininet Topology - PASS (tick)
  • 56.8 Check whether the flow count is bigger than 74 - PASS (tick)
  • 56.9 Check whether all flow status are ADDED - PASS (tick)
  • 56.10 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 56.11 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 56.12 Verify full connectivity for [u'h1', u'h2'] with tag CASE56 - PASS (tick)
  • 56.13 Stopping Mininet - PASS (tick)
  • 56.14 Copying karaf logs - PASS (tick)

Case 57: Bridging test between two untagged hosts with different vlan id, with 2x2 leaf-spine topology and 3 ONOS instances -

...

PASS

  • 57.1 Apply cell to environment - PASS (tick)
  • 57.2 Uninstalling ONOS package - PASS (tick)
  • 57.3 Installing ONOS package - PASS (tick)
  • 57.4 Set up ONOS secure SSH - PASS (tick)
  • 57.5 Checking ONOS service - PASS (tick)
  • 57.6 Starting ONOS CLI sessions - PASS (tick)
  • 57.7 Starting Mininet Topology - PASS (tick)
  • 57.8 Check whether the flow count is bigger than 74 - PASS (tick)
  • 57.9 Check whether all flow status are ADDED - PASS (tick)
  • 57.10 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 57.11 Check whether the flow count of device of:0000000000000002 is bigger than 37 - FAIL (error)
  • Flow count looks wrong.
  • PASS (tick)
  • 57.12 Verify full connectivity for [u'h1', u'h2'] with tag CASE57 - PASS (tick)
  • 57.13 Verify full connectivity for [u'h3', u'h4'] with tag CASE57 - PASS (tick)
  • 57.14 Stopping Mininet - PASS (tick)
  • 57.15 Copying karaf logs - PASS (tick)

...