Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Published from Jenkins build: https://jenkins.onosproject.org/job/SR-pipeline-master/110/

...

commit 9d59694e5f2c34f39524b5ff11905f827ff4d672 (HEAD -] master, origin/master, origin/HEAD)
Author: Yuta HIGUCHI [y-higuchi@ak.jp.nec.com]
AuthorDate: Wed May 23 14:09:05 2018 -0700
Commit: Yuta HIGUCHI [y-higuchi@opennetworking.org]
CommitDate: Fri May 25 21:33:11 2018 +0000

Update Bouncy Castle to 1.59

Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR and 3 ONOS instances -

...

FAIL

  • 5.1 Constructing test variables - PASS (tick)
  • 5.2 Apply cell to environment - PASS (tick)
  • 5.3 Uninstalling ONOS package - PASS (tick)
  • 5.4 Creating ONOS package - PASS (tick)
  • 5.5 Installing ONOS package - PASS (tick)
  • 5.6 Set up ONOS secure SSH - PASS (tick)
  • 5.7 Checking ONOS service - PASS (tick)
  • 5.8 Starting ONOS CLI sessions - PASS (tick)
  • 5.9 Starting Mininet Topology - PASS (tick)
  • 5.10 Check whether the flow count is bigger than 28 - PASS (tick)FAIL (error)
    • Flow count looks wrong: False
  • 5.11 Check whether all flow status are ADDED - PASS (tick)
  • 5.12 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS (tick)FAIL (error)
    • Flow count looks wrong.
  • 5.13 Verify full connectivity for [u'h1', u'h2'] with tag CASE5 - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 5.14 Stopping Mininet - PASS (tick)
  • 5.15 Copying karaf logs - PASS (tick)

...