Due to a ransomware attack, the wiki was reverted to a July 2022 version. . We apologize for the lack of a more recent valid backup.
...
- 83.1 Apply cell to environment - PASS
- 83.2 Uninstalling ONOS package - PASS
- 83.3 Installing ONOS package - PASS
- 83.4 Set up ONOS secure SSH - PASS
- 83.5 Checking ONOS service - PASS
- 83.6 Starting ONOS CLI sessions - PASS
- 83.7 Starting Mininet Topology - PASS
- 83.8 Check whether the flow count is bigger than 104 - PASS
- 83.9 Check whether all flow status are ADDED - PASS
- 83.10 Verify full connectivity for [u'h3', u'h4'] with tag CASE83_Before - PASS
- 83.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE83_Before - PASS
- 83.12 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 83.13 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 83.14 Check whether the flow count is bigger than 104 - PASS
- 83.15 Check whether all flow status are ADDED - PASS
- 83.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE83_After - PASS
- 83.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE83_After - PASS
- 83.18 Stopping Mininet - PASS
- 83.19 Copying karaf logs - PASS
Case 93: Changing port configuration from tagged 10 to tagged 120 with native 110, with 2x2 leaf-spine topology and 3 ONOS instances -
...
PASS
- 93.1 Apply cell to environment - PASS
- 93.2 Uninstalling ONOS package - PASS
- 93.3 Installing ONOS package - PASS
- 93.4 Set up ONOS secure SSH - PASS
- 93.5 Checking ONOS service - PASS
- 93.6 Starting ONOS CLI sessions - PASS
- 93.7 Starting Mininet Topology - PASS
- 93.8 Check whether the flow count is bigger than 106 - PASS
- 93.9 Check whether all flow status are ADDED - PASS
- 93.10 Verify full connectivity for [u'h3', u'h4'] with tag CASE93_Before - PASS
- 93.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE93_Before - PASS
- 93.12 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 93.13 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 93.14 Check whether the flow count is bigger than 106 - PASS
- 93.15 Check whether all flow status are ADDED - FAIL
- PASS
- 93.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE93_After - PASS
- 93.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE93_After - PASS
- 93.18 Stopping Mininet - PASS
- 93.19 Copying karaf logs - PASS
...