  • 63.1 Apply cell to environment - PASS (tick)
  • 63.2 Uninstalling ONOS package - PASS (tick)
  • 63.3 Installing ONOS package - PASS (tick)
  • 63.4 Set up ONOS secure SSH - PASS (tick)
  • 63.5 Checking ONOS service - PASS (tick)
  • 63.6 Starting ONOS CLI sessions - PASS (tick)
  • 63.7 Starting Mininet Topology - PASS (tick)
  • 63.8 Check whether the flow count is bigger than 104 - PASS (tick)
  • 63.9 Check whether all flow status are ADDED - PASS (tick)
  • 63.10 Verify full connectivity for [u'h3', u'h4'] with tag CASE63_Before - PASS (tick)
  • 63.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE63_Before - PASS (tick)
  • 63.12 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 63.13 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 63.14 Check whether the flow count is bigger than 104 - PASS (tick)
  • 63.15 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 63.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE63_After - PASS (tick)
  • 63.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE63_After - PASS (tick)
  • 63.18 Stopping Mininet - PASS (tick)
  • 63.19 Copying karaf logs - PASS (tick)

Case 73: Changing port configuration from tagged 10 to untagged 10, with 2x2 leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 73.1 Apply cell to environment - PASS (tick)
  • 73.2 Uninstalling ONOS package - PASS (tick)
  • 73.3 Installing ONOS package - PASS (tick)
  • 73.4 Set up ONOS secure SSH - PASS (tick)
  • 73.5 Checking ONOS service - PASS (tick)
  • 73.6 Starting ONOS CLI sessions - PASS (tick)
  • 73.7 Starting Mininet Topology - PASS (tick)
  • 73.8 Check whether the flow count is bigger than 106 - PASS (tick)
  • 73.9 Check whether all flow status are ADDED - PASS (tick)
  • 73.10 Verify full connectivity for [u'h3', u'h4'] with tag CASE73_Before - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 73.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE73_Before - PASS (tick)
  • 73.12 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 73.13 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 73.14 Check whether the flow count is bigger than 106 - PASS (tick)
  • 73.15 Check whether all flow status are ADDED - PASS (tick)
  • 73.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE73_After - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 73.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE73_After - PASS (tick)
  • 73.18 Stopping Mininet - PASS (tick)
  • 73.19 Copying karaf logs - PASS (tick)

...

  • 83.1 Apply cell to environment - PASS (tick)
  • 83.2 Uninstalling ONOS package - PASS (tick)
  • 83.3 Installing ONOS package - PASS (tick)
  • 83.4 Set up ONOS secure SSH - PASS (tick)
  • 83.5 Checking ONOS service - PASS (tick)
  • 83.6 Starting ONOS CLI sessions - PASS (tick)
  • 83.7 Starting Mininet Topology - PASS (tick)
  • 83.8 Check whether the flow count is bigger than 104 - PASS (tick)
  • 83.9 Check whether all flow status are ADDED - PASS (tick)
  • 83.10 Verify full connectivity for [u'h3', u'h4'] with tag CASE83_Before - PASS (tick)
  • 83.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE83_Before - PASS (tick)
  • 83.12 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 83.13 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 83.14 Check whether the flow count is bigger than 104 - PASS (tick)
  • 83.15 Check whether all flow status are ADDED - PASS (tick)
  • 83.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE83_After - PASS (tick)
  • 83.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE83_After - PASS (tick)
  • 83.18 Stopping Mininet - PASS (tick)
  • 83.19 Copying karaf logs - PASS (tick)

Case 93: Changing port configuration from tagged 10 to tagged 120 with native 110, with 2x2 leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 93.1 Apply cell to environment - PASS (tick)
  • 93.2 Uninstalling ONOS package - PASS (tick)
  • 93.3 Installing ONOS package - PASS (tick)
  • 93.4 Set up ONOS secure SSH - PASS (tick)
  • 93.5 Checking ONOS service - PASS (tick)
  • 93.6 Starting ONOS CLI sessions - PASS (tick)
  • 93.7 Starting Mininet Topology - PASS (tick)
  • 93.8 Check whether the flow count is bigger than 106 - PASS (tick)
  • 93.9 Check whether all flow status are ADDED - PASS (tick)
  • 93.10 Verify full connectivity for [u'h3', u'h4'] with tag CASE93_Before - PASS (tick)
  • 93.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE93_Before - PASS (tick)
  • 93.12 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 93.13 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 93.14 Check whether the flow count is bigger than 106 - PASS (tick)
  • 93.15 Check whether all flow status are ADDED - PASS (tick)FAIL (error)
    • Flow status is wrong!
  • 93.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE93_After - PASS (tick)
  • 93.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE93_After - PASS (tick)
  • 93.18 Stopping Mininet - PASS (tick)
  • 93.19 Copying karaf logs - PASS (tick)

...