Due to a ransomware attack, the wiki was reverted to a July 2022 version. . We apologize for the lack of a more recent valid backup.
...
| HTML |
|---|
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric4/lastSuccessfulBuild/artifact/SRBridging_master_20-builds_graph.jpg", alt="SRBridging", style="width:525px;height:350px;border:0"> |
commit 9d59694e5f2c34f39524b5ff11905f827ff4d672 5cdf3ac81005008edafefbb6260e89d4197ca6aa (HEAD -] master, origin/master, origin/HEAD)
Author: Yuta HIGUCHI [y-higuchi@ak.jp.nec.Daniel Park [dan.park@sk.com]
AuthorDate: Wed Tue May 23 1429 10:0910:05 31 2018 -0700+0900
Commit: Yuta HIGUCHI [y-higuchi@opennetworking.orgDaniel Park [dan.park@sk.com]
CommitDate: Fri Tue May 25 2129 10:3310:11 31 2018 +0000
Update Bouncy Castle to 1.590900
Fixes floating IP rules installed on compute nodes disappear after 60s
Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR and 3 ONOS instances -
...
FAIL
- 5.1 Constructing test variables - PASS
- 5.2 Apply cell to environment - PASS
- 5.3 Uninstalling ONOS package - PASS
- 5.4 Creating ONOS package - PASS
- 5.5 Installing ONOS package - PASS
- 5.6 Set up ONOS secure SSH - PASS
- 5.7 Checking ONOS service - PASS
- 5.8 Starting ONOS CLI sessions - PASS
- 5.9 Starting Mininet Topology - PASS
- 5.10 Check whether the flow count is bigger than 28 - PASS
FAIL
- Flow count looks wrong: False
- 5.11 Check whether all flow status are ADDED - PASS
- 5.12 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS
FAIL
- Flow count looks wrong.
- 5.13 Verify full connectivity for [u'h1', u'h2'] with tag CASE5 - PASS
FAIL
- IP connectivity failed
- 5.14 Stopping Mininet - PASS
- 5.15 Copying karaf logs - PASS
...
- 18.1 Apply cell to environment - PASS
- 18.2 Uninstalling ONOS package - PASS
- 18.3 Installing ONOS package - PASS
- 18.4 Set up ONOS secure SSH - PASS
- 18.5 Checking ONOS service - PASS
- 18.6 Starting ONOS CLI sessions - PASS
- 18.7 Starting Mininet Topology - PASS
- 18.8 Check whether the flow count is bigger than 212 - PASS
- 18.9 Check whether all flow status are ADDED - PASS
- 18.10 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 18.11 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 18.12 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS
- 18.13 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS
- 18.14 Verify full connectivity for [u'h1', u'h2'] with tag CASE18 - PASS
- 18.15 Verify full connectivity for [u'h3', u'h4'] with tag CASE18 - PASS
- 18.16 Stopping Mininet - PASS
- 18.17 Copying karaf logs - PASS
Case 25: Bridging test between two untagged hosts on vlan-native port, with single ToR and 3 ONOS instances -
...
FAIL
- 25.1 Apply cell to environment - PASS
- 25.2 Uninstalling ONOS package - PASS
- 25.3 Installing ONOS package - PASS
- 25.4 Set up ONOS secure SSH - PASS
- 25.5 Checking ONOS service - PASS
- 25.6 Starting ONOS CLI sessions - PASS
- 25.7 Starting Mininet Topology - PASS
- 25.8 Check whether the flow count is bigger than 28 - PASS
FAIL
- Flow count looks wrong: False
- 25.9 Check whether all flow status are ADDED - PASS
- 25.10 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS
FAIL
- Flow count looks wrong.
- 25.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE25 - PASS
FAIL
- IP connectivity failed
- 25.12 Stopping Mininet - PASS
- 25.13 Copying karaf logs - PASS
...