Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Published from Jenkins build: https://jenkins.onosproject.org/job/SR-pipeline-master/118/

...

HTML
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric4/lastSuccessfulBuild/artifact/SRDynamicConf_master_20-builds_graph.jpg", alt="SRDynamicConf", style="width:525px;height:350px;border:0">

commit 35cc3e6142e15c699b6668676b3faceede356603 f4ed521142fc861739b8e86ccc691b3e9c9701e8 (HEAD -] master, origin/master, origin/HEAD)
Author: sdn hiroki [jy0624hiroki.seo@samsungokui@gmail.com]
AuthorDate: Fri Jun 1 18:08:41 2018 +0900Sat May 26 22:39:38 2018 -0700
Commit: Yuta HIGUCHI [y-higuchi@opennetworking.orghiroki [hiroki.okui@gmail.com]
CommitDate: Fri Sat Jun 1 222 11:0415:24 11 2018 +0000-0700

[Bug Fix]Check NullPointer Exception at driver pipelinerODTN] Add read/create/delete ConnectivityService RPC

Case 13: Changing port configuration from untagged 10 to tagged 10, with 2x2 leaf-spine topology and 3 ONOS instances - FAIL

...

  • 193.1 Apply cell to environment - PASS (tick)
  • 193.2 Uninstalling ONOS package - PASS (tick)
  • 193.3 Installing ONOS package - PASS (tick)
  • 193.4 Set up ONOS secure SSH - PASS (tick)
  • 193.5 Checking ONOS service - PASS (tick)
  • 193.6 Starting ONOS CLI sessions - PASS (tick)
  • 193.7 Starting Mininet Topology - PASS (tick)
  • 193.8 Check whether the flow count is bigger than 106 - PASS (tick)
  • 193.9 Check whether all flow status are ADDED - PASS (tick)FAIL (error)
    • Flow status is wrong!
  • 193.10 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE193_Before - PASS (tick)
  • 193.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE193_Before - PASS (tick)
  • 193.12 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 193.13 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 193.14 Check whether the flow count is bigger than 106 - PASS (tick)
  • 193.15 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 193.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE193_After - PASS (tick)
  • 193.17 Verify full connectivity for [u'h1', u'h2', u'h3'] with tag CASE193_After - PASS (tick)
  • 193.18 Stopping Mininet - PASS (tick)
  • 193.19 Copying karaf logs - PASS (tick)

...