Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Published from Jenkins build: https://jenkins.onosproject.org/job/SR-pipeline-master/121/

...

HTML
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric4/lastSuccessfulBuild/artifact/SRBridging_master_20-builds_graph.jpg", alt="SRBridging", style="width:525px;height:350px;border:0">

commit 61b4c34e216fdb3357bcf0ff1efaa00693b5960d f3a28b0c3641773c4b2ade977ec62731b080a5e4 (HEAD -] master, origin/master, origin/HEAD)
Author: Ray Milkey Jian Li [ray@opennetworkingpyguni@gmail.orgcom]
AuthorDate: Fri Mon Jun 8 0911 21:3629:57 13 2018 -0700+0900
Commit: Ray Milkey Jian Li [ray@opennetworkingpyguni@gmail.orgcom]
CommitDate: Fri Mon Jun 8 2011 23:5602:43 53 2018 +0000
Fix maven swagger build of Cisco rest driver0900

Fix: remove FixedIpAddress associated with FloatingIp when purge VM

Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR and 3 ONOS instances - FAIL

...

  • 5.1 Constructing test variables - PASS (tick)
  • 5.2 Apply cell to environment - PASS (tick)
  • 5.3 Uninstalling ONOS package - PASS (tick)
  • 5.4 Creating ONOS package - PASS (tick)
  • 5.5 Installing ONOS package - PASS (tick)
  • 5.6 Set up ONOS secure SSH - PASS (tick)
  • 5.7 Checking ONOS service - PASS (tick)
  • 5.8 Starting ONOS CLI sessions - PASS (tick)
  • 5.9 Starting Mininet Topology - PASS (tick)
  • 5.10 Check whether the flow count is bigger than 28 - PASS (tick)FAIL (error)
    • Flow count looks wrong: False
  • 5.11 Check whether all flow status are ADDED - FAIL (error)
  • Flow status is wrong!
  • PASS (tick)
  • 5.12 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS (tick)FAIL (error)
    • Flow count looks wrong.
  • 5.13 Verify full connectivity for [u'h1', u'h2'] with tag CASE5 - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 5.14 Stopping Mininet - PASS (tick)
  • 5.15 Copying karaf logs - PASS (tick)

...

  • 8.1 Apply cell to environment - PASS (tick)
  • 8.2 Uninstalling ONOS package - PASS (tick)
  • 8.3 Installing ONOS package - PASS (tick)
  • 8.4 Set up ONOS secure SSH - PASS (tick)
  • 8.5 Checking ONOS service - PASS (tick)
  • 8.6 Starting ONOS CLI sessions - PASS (tick)
  • 8.7 Starting Mininet Topology - PASS (tick)
  • 8.8 Check whether the flow count is bigger than 212 - PASS (tick)
  • 8.9 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 8.10 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 8.11 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 8.12 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS (tick)
  • 8.13 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS (tick)
  • 8.14 Verify full connectivity for [u'h1', u'h2'] with tag CASE8 - PASS (tick)
  • 8.15 Verify full connectivity for [u'h3', u'h4'] with tag CASE8 - PASS (tick)
  • 8.16 Stopping Mininet - PASS (tick)
  • 8.17 Copying karaf logs - PASS (tick)

Case 15: Bridging test between two tagged hosts, with single ToR and 3 ONOS instances -

...

PASS

  • 15.1 Apply cell to environment - PASS (tick)
  • 15.2 Uninstalling ONOS package - PASS (tick)
  • 15.3 Installing ONOS package - PASS (tick)
  • 15.4 Set up ONOS secure SSH - PASS (tick)
  • 15.5 Checking ONOS service - PASS (tick)
  • 15.6 Starting ONOS CLI sessions - PASS (tick)
  • 15.7 Starting Mininet Topology - PASS (tick)
  • 15.8 Check whether the flow count is bigger than 28 - PASS (tick)
  • 15.9 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • PASS (tick)
  • 15.10 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS (tick)
  • 15.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE15 - PASS (tick)
  • 15.12 Stopping Mininet - PASS (tick)
  • 15.13 Copying karaf logs - PASS (tick)

...

  • 38.1 Apply cell to environment - PASS (tick)
  • 38.2 Uninstalling ONOS package - PASS (tick)
  • 38.3 Installing ONOS package - PASS (tick)
  • 38.4 Set up ONOS secure SSH - PASS (tick)
  • 38.5 Checking ONOS service - PASS (tick)
  • 38.6 Starting ONOS CLI sessions - PASS (tick)
  • 38.7 Starting Mininet Topology - PASS (tick)
  • 38.8 Check whether the flow count is bigger than 212 - PASS (tick)
  • 38.9 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 38.10 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 38.11 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 38.12 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS (tick)
  • 38.13 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS (tick)
  • 38.14 Verify full connectivity for [u'h1', u'h2'] with tag CASE38 - PASS (tick)
  • 38.15 Verify full connectivity for [u'h3', u'h4'] with tag CASE38 - PASS (tick)
  • 38.16 Stopping Mininet - PASS (tick)
  • 38.17 Copying karaf logs - PASS (tick)

Case 45: Bridging test between untagged host and tagged host, with single ToR and 3 ONOS instances -

...

FAIL

  • 45.1 Apply cell to environment - PASS (tick)
  • 45.2 Uninstalling ONOS package - PASS (tick)
  • 45.3 Installing ONOS package - PASS (tick)
  • 45.4 Set up ONOS secure SSH - PASS (tick)
  • 45.5 Checking ONOS service - PASS (tick)
  • 45.6 Starting ONOS CLI sessions - PASS (tick)
  • 45.7 Starting Mininet Topology - PASS (tick)
  • 45.8 Check whether the flow count is bigger than 28 - PASS (tick)
  • 45.9 Check whether all flow status are ADDED - PASS (tick)FAIL (error)
    • Flow status is wrong!
  • 45.10 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS (tick)
  • 45.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE45 - PASS (tick)
  • 45.12 Stopping Mininet - PASS (tick)
  • 45.13 Copying karaf logs - PASS (tick)

...

  • 48.1 Apply cell to environment - PASS (tick)
  • 48.2 Uninstalling ONOS package - PASS (tick)
  • 48.3 Installing ONOS package - PASS (tick)
  • 48.4 Set up ONOS secure SSH - PASS (tick)
  • 48.5 Checking ONOS service - PASS (tick)
  • 48.6 Starting ONOS CLI sessions - PASS (tick)
  • 48.7 Starting Mininet Topology - PASS (tick)
  • 48.8 Check whether the flow count is bigger than 212 - PASS (tick)
  • 48.9 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 48.10 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 48.11 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 48.12 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS (tick)
  • 48.13 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS (tick)
  • 48.14 Verify full connectivity for [u'h1', u'h2'] with tag CASE48 - PASS (tick)
  • 48.15 Verify full connectivity for [u'h3', u'h4'] with tag CASE48 - PASS (tick)
  • 48.16 Stopping Mininet - PASS (tick)
  • 48.17 Copying karaf logs - PASS (tick)

Case 55: Bridging test between two untagged hosts with different vlan id, with single ToR and 3 ONOS instances -

...

FAIL

  • 55.1 Apply cell to environment - PASS (tick)
  • 55.2 Uninstalling ONOS package - PASS (tick)
  • 55.3 Installing ONOS package - PASS (tick)
  • 55.4 Set up ONOS secure SSH - PASS (tick)
  • 55.5 Checking ONOS service - PASS (tick)
  • 55.6 Starting ONOS CLI sessions - PASS (tick)
  • 55.7 Starting Mininet Topology - PASS (tick)
  • 55.8 Check whether the flow count is bigger than 28 - PASS (tick)FAIL (error)
    • Flow count looks wrong: False
  • 55.9 Check whether all flow status are ADDED - PASS (tick)
  • 55.10 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS (tick)FAIL (error)
    • Flow count looks wrong.
  • 55.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE55 - PASS (tick)
  • 55.12 Stopping Mininet - PASS (tick)
  • 55.13 Copying karaf logs - PASS (tick)

...