commit 59cf0c877c74f0bd08d826dd8d1eb759a5014e33 648b538ed8af49a790daa94c3ac8af983eb9f665 (HEAD -] master, origin/master, origin/HEAD)
Author: Yuta HIGUCHI [y-higuchi@ak.jp.necAlessio Giorgetti [alessio.giorgetti@gmail.com]
AuthorDate: Wed May 23 14:16:59 2018 -0700Thu Feb 15 18:35:45 2018 +0100
Commit: Yuta HIGUCHI [y-higuchi@opennetworking.org]
CommitDate: Thu Fri Jun 14 1615 22:0415:29 50 2018 +0000
Update dependencies
Lumentum ROADM-20 Whitebox, NETCONF driver supporting ROADM app main functionalities

Case 13: Changing port configuration from untagged 10 to tagged 10, with 2x2 leaf-spine topology and 3 ONOS instances - FAIL

...

  • 13.1 Constructing test variables - PASS (tick)
  • 13.2 Apply cell to environment - PASS (tick)
  • 13.3 Uninstalling ONOS package - PASS (tick)
  • 13.4 Creating ONOS package - PASS (tick)
  • 13.5 Installing ONOS package - PASS (tick)
  • 13.6 Set up ONOS secure SSH - PASS (tick)
  • 13.7 Checking ONOS service - PASS (tick)
  • 13.8 Starting ONOS CLI sessions - PASS (tick)
  • 13.9 Starting Mininet Topology - PASS (tick)
  • 13.10 Check whether the flow count is bigger than 104 - FAIL (error)
    • Flow count looks wrong: False
  • 13.11 Check whether all flow status are ADDED - PASS (tick)FAIL (error)
    • Flow status is wrong!
  • 13.12 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE13_Before - PASS (tick)
  • 13.13 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 13.14 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 13.15 Check whether the flow count is bigger than 104 - FAIL (error)
    • Flow count looks wrong: False
  • 13.16 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 13.17 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE13_After - PASS (tick)
  • 13.18 Stopping Mininet - PASS (tick)
  • 13.19 Copying karaf logs - PASS (tick)

...

  • 33.1 Apply cell to environment - PASS (tick)
  • 33.2 Uninstalling ONOS package - PASS (tick)
  • 33.3 Installing ONOS package - PASS (tick)
  • 33.4 Set up ONOS secure SSH - PASS (tick)
  • 33.5 Checking ONOS service - PASS (tick)
  • 33.6 Starting ONOS CLI sessions - PASS (tick)
  • 33.7 Starting Mininet Topology - PASS (tick)
  • 33.8 Check whether the flow count is bigger than 104 - PASS (tick)FAIL (error)
    • Flow count looks wrong: False
  • 33.9 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 33.10 Verify full connectivity for [u'h3', u'h4'] with tag CASE33_Before - PASS (tick)
  • 33.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE33_Before - PASS (tick)
  • 33.12 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 33.13 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 33.14 Check whether the flow count is bigger than 104 - PASS (tick)FAIL (error)
    • Flow count looks wrong: False
  • 33.15 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 33.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE33_After - PASS (tick)
  • 33.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE33_After - PASS (tick)
  • 33.18 Stopping Mininet - PASS (tick)
  • 33.19 Copying karaf logs - PASS (tick)

...

  • 43.1 Apply cell to environment - PASS (tick)
  • 43.2 Uninstalling ONOS package - PASS (tick)
  • 43.3 Installing ONOS package - PASS (tick)
  • 43.4 Set up ONOS secure SSH - PASS (tick)
  • 43.5 Checking ONOS service - PASS (tick)
  • 43.6 Starting ONOS CLI sessions - PASS (tick)
  • 43.7 Starting Mininet Topology - PASS (tick)
  • 43.8 Check whether the flow count is bigger than 104 - PASS (tick)FAIL (error)
    • Flow count looks wrong: False
  • 43.9 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 43.10 Verify full connectivity for [u'h3', u'h4'] with tag CASE43_Before - PASS (tick)
  • 43.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE43_Before - PASS (tick)
  • 43.12 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 43.13 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 43.14 Check whether the flow count is bigger than 104 - PASS (tick)FAIL (error)
    • Flow count looks wrong: False
  • 43.15 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 43.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE43_After - PASS (tick)
  • 43.17 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE43_After - PASS (tick)
  • 43.18 Stopping Mininet - PASS (tick)
  • 43.19 Copying karaf logs - PASS (tick)

...

  • 53.1 Apply cell to environment - PASS (tick)
  • 53.2 Uninstalling ONOS package - PASS (tick)
  • 53.3 Installing ONOS package - PASS (tick)
  • 53.4 Set up ONOS secure SSH - PASS (tick)
  • 53.5 Checking ONOS service - PASS (tick)
  • 53.6 Starting ONOS CLI sessions - PASS (tick)
  • 53.7 Starting Mininet Topology - PASS (tick)
  • 53.8 Check whether the flow count is bigger than 104 - FAIL (error)
  • Flow count looks wrong: False
  • PASS (tick)
  • 53.9 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 53.10 Verify full connectivity for [u'h3', u'h4'] with tag CASE53_Before - PASS (tick)
  • 53.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE53_Before - PASS (tick)
  • 53.12 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 53.13 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 53.14 Check whether the flow count is bigger than 104 - FAIL (error)
  • Flow count looks wrong: False
  • PASS (tick)
  • 53.15 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 53.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE53_After - PASS (tick)
  • 53.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE53_After - PASS (tick)
  • 53.18 Stopping Mininet - PASS (tick)
  • 53.19 Copying karaf logs - PASS (tick)

...

  • 93.1 Apply cell to environment - PASS (tick)
  • 93.2 Uninstalling ONOS package - PASS (tick)
  • 93.3 Installing ONOS package - PASS (tick)
  • 93.4 Set up ONOS secure SSH - PASS (tick)
  • 93.5 Checking ONOS service - PASS (tick)
  • 93.6 Starting ONOS CLI sessions - PASS (tick)
  • 93.7 Starting Mininet Topology - PASS (tick)
  • 93.8 Check whether the flow count is bigger than 106 - FAIL (error)
  • Flow count looks wrong: False
  • PASS (tick)
  • 93.9 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 93.10 Verify full connectivity for [u'h3', u'h4'] with tag CASE93_Before - PASS (tick)
  • 93.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE93_Before - PASS (tick)
  • 93.12 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 93.13 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 93.14 Check whether the flow count is bigger than 106 - FAIL (error)
  • Flow count looks wrong: False
  • PASS (tick)
  • 93.15 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 93.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE93_After - PASS (tick)
  • 93.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE93_After - PASS (tick)
  • 93.18 Stopping Mininet - PASS (tick)
  • 93.19 Copying karaf logs - PASS (tick)

...

  • 113.1 Apply cell to environment - PASS (tick)
  • 113.2 Uninstalling ONOS package - PASS (tick)
  • 113.3 Installing ONOS package - PASS (tick)
  • 113.4 Set up ONOS secure SSH - PASS (tick)
  • 113.5 Checking ONOS service - PASS (tick)
  • 113.6 Starting ONOS CLI sessions - PASS (tick)
  • 113.7 Starting Mininet Topology - PASS (tick)
  • 113.8 Check whether the flow count is bigger than 104 - PASS (tick)FAIL (error)
    • Flow count looks wrong: False
  • 113.9 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 113.10 Verify full connectivity for [u'h3', u'h4'] with tag CASE113_Before - PASS (tick)
  • 113.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE113_Before - PASS (tick)
  • 113.12 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 113.13 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 113.14 Check whether the flow count is bigger than 104 - PASS (tick)FAIL (error)
    • Flow count looks wrong: False
  • 113.15 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 113.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE113_After - PASS (tick)
  • 113.17 Verify full connectivity for [u'h1', u'h2', u'h3'] with tag CASE113_After - PASS (tick)
  • 113.18 Stopping Mininet - PASS (tick)
  • 113.19 Copying karaf logs - PASS (tick)

...

  • 123.1 Apply cell to environment - PASS (tick)
  • 123.2 Uninstalling ONOS package - PASS (tick)
  • 123.3 Installing ONOS package - PASS (tick)
  • 123.4 Set up ONOS secure SSH - PASS (tick)
  • 123.5 Checking ONOS service - PASS (tick)
  • 123.6 Starting ONOS CLI sessions - PASS (tick)
  • 123.7 Starting Mininet Topology - PASS (tick)
  • 123.8 Check whether the flow count is bigger than 104 - FAIL (error)
    • Flow count looks wrong: False
  • 123.9 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 123.10 Verify full connectivity for [u'h3', u'h4'] with tag CASE123_Before - PASS (tick)
  • 123.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE123_Before - PASS (tick)
  • 123.12 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 123.13 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 123.14 Check whether the flow count is bigger than 104 - PASS (tick)FAIL (error)
    • Flow count looks wrong: False
  • 123. 123.15 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 123.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE123_After - PASS (tick)
  • 123.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE123_After - PASS (tick)
  • 123.18 Stopping Mininet - PASS (tick)
  • 123.19 Copying karaf logs - PASS (tick)

...

  • 133.1 Apply cell to environment - PASS (tick)
  • 133.2 Uninstalling ONOS package - PASS (tick)
  • 133.3 Installing ONOS package - PASS (tick)
  • 133.4 Set up ONOS secure SSH - PASS (tick)
  • 133.5 Checking ONOS service - PASS (tick)
  • 133.6 Starting ONOS CLI sessions - PASS (tick)
  • 133.7 Starting Mininet Topology - PASS (tick)
  • 133.8 Check whether the flow count is bigger than 104 - PASS (tick)FAIL (error)
    • Flow count looks wrong: False
  • 133.9 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 133.10 Verify full connectivity for [u'h3', u'h4'] with tag CASE133_Before - PASS (tick)
  • 133.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE133_Before - PASS (tick)
  • 133.12 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 133.13 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 133.14 Check whether the flow count is bigger than 104 - PASS (tick)FAIL (error)
    • Flow count looks wrong: False
  • 133.15 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 133.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE133_After - PASS (tick)
  • 133.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE133_After - PASS (tick)
  • 133.18 Stopping Mininet - PASS (tick)
  • 133.19 Copying karaf logs - PASS (tick)

...

  • 143.1 Apply cell to environment - PASS (tick)
  • 143.2 Uninstalling ONOS package - PASS (tick)
  • 143.3 Installing ONOS package - PASS (tick)
  • 143.4 Set up ONOS secure SSH - PASS (tick)
  • 143.5 Checking ONOS service - PASS (tick)
  • 143.6 Starting ONOS CLI sessions - PASS (tick)
  • 143.7 Starting Mininet Topology - PASS (tick)
  • 143.8 Check whether the flow count is bigger than 106 - FAIL (error)
  • Flow count looks wrong: False
  • PASS (tick)
  • 143.9 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 143.10 Verify full connectivity for [u'h3', u'h4'] with tag CASE143_Before - PASS (tick)
  • 143.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE143_Before - PASS (tick)
  • 143.12 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 143.13 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 143.14 Check whether the flow count is bigger than 106 - FAIL (error)
  • Flow count looks wrong: False
  • PASS (tick)
  • 143.15 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 143.16 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE143_After - PASS (tick)
  • 143.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE143_After - PASS (tick)
  • 143.18 Stopping Mininet - PASS (tick)
  • 143.19 Copying karaf logs - PASS (tick)

...

  • 153.1 Apply cell to environment - PASS (tick)
  • 153.2 Uninstalling ONOS package - PASS (tick)
  • 153.3 Installing ONOS package - PASS (tick)
  • 153.4 Set up ONOS secure SSH - PASS (tick)
  • 153.5 Checking ONOS service - PASS (tick)
  • 153.6 Starting ONOS CLI sessions - PASS (tick)
  • 153.7 Starting Mininet Topology - PASS (tick)
  • 153.8 Check whether the flow count is bigger than 106 - FAIL (error)
  • Flow count looks wrong: False
  • PASS (tick)
  • 153.9 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 153.10 Verify full connectivity for [u'h3', u'h4'] with tag CASE153_Before - PASS (tick)
  • 153.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE153_Before - PASS (tick)
  • 153.12 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 153.13 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 153.14 Check whether the flow count is bigger than 106 - FAIL (error)
  • Flow count looks wrong: False
  • PASS (tick)
  • 153.15 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 153.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE153_After - PASS (tick)
  • 153.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE153_After - PASS (tick)
  • 153.18 Stopping Mininet - PASS (tick)
  • 153.19 Copying karaf logs - PASS (tick)

...

  • 183.1 Apply cell to environment - PASS (tick)
  • 183.2 Uninstalling ONOS package - PASS (tick)
  • 183.3 Installing ONOS package - PASS (tick)
  • 183.4 Set up ONOS secure SSH - PASS (tick)
  • 183.5 Checking ONOS service - PASS (tick)
  • 183.6 Starting ONOS CLI sessions - PASS (tick)
  • 183.7 Starting Mininet Topology - PASS (tick)
  • 183.8 Check whether the flow count is bigger than 106 - PASS (tick)FAIL (error)
    • Flow count looks wrong: False
  • 183.9 Check whether all flow status are ADDED - FAIL (error)
  • Flow status is wrong!
  • PASS (tick)
  • 183.10 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE183_Before - PASS (tick)
  • 183.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE183_Before - PASS (tick)
  • 183.12 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 183.13 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 183.14 Check whether the flow count is bigger than 106 - PASS (tick)FAIL (error)
    • Flow count looks wrong: False
  • 183.15 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 183.16 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE183_After - PASS (tick)
  • 183.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE183_After - PASS (tick)
  • 183.18 Stopping Mininet - PASS (tick)
  • 183.19 Copying karaf logs - PASS (tick)

...

  • 233.1 Apply cell to environment - PASS (tick)
  • 233.2 Uninstalling ONOS package - PASS (tick)
  • 233.3 Installing ONOS package - PASS (tick)
  • 233.4 Set up ONOS secure SSH - PASS (tick)
  • 233.5 Checking ONOS service - PASS (tick)
  • 233.6 Starting ONOS CLI sessions - PASS (tick)
  • 233.7 Starting Mininet Topology - PASS (tick)
  • 233.8 Check whether the flow count is bigger than 104 - FAIL (error)
    • Flow count looks wrong: False
  • 233.9 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 233.10 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_Before - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 233.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_Before - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 233.12 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 233.13 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 233.14 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 233.15 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 233.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_1 - FAIL (error)
    • IP connectivity failed
  • PASS (tick)
  • 233.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_1 - PASS (tick)
  • 233.18 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 233.19 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 233.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_2 - FAIL (error)
    • IP connectivity failed
  • PASS (tick)
  • 233.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_2 - PASS (tick)
  • 233.22 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 233.23 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 233.24 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_3 - FAIL (error)
    • IP connectivity failed
  • PASS (tick)
  • 233.25 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_3 - PASS (tick)
  • 233.26 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 233.27 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 233.28 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_4 - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 233.29 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_4 - FAIL (error)
    • IP connectivity failed
  • 233.30 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 233.31 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 233.32 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_5 - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 233.33 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_5 - PASS (tick)
  • 233.34 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 233.35 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 233.36 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_6 - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 233.37 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_6 - PASS (tick)
  • 233.38 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 233.39 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 233.40 Check whether the flow count is bigger than 104 - FAIL (error)
    • Flow count looks wrong: False
  • 233.41 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 233.42 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_After - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 233.43 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_After - FAIL (error)
    • IP connectivity failed
  • PASS (tick)
  • 233.44 Stopping Mininet - PASS (tick)
  • 233.45 Copying karaf logs - PASS (tick)

...

  • 243.1 Apply cell to environment - PASS (tick)
  • 243.2 Uninstalling ONOS package - PASS (tick)
  • 243.3 Installing ONOS package - PASS (tick)
  • 243.4 Set up ONOS secure SSH - PASS (tick)
  • 243.5 Checking ONOS service - PASS (tick)
  • 243.6 Starting ONOS CLI sessions - PASS (tick)
  • 243.7 Starting Mininet Topology - PASS (tick)
  • 243.8 Check whether the flow count is bigger than 104 - PASS (tick)FAIL (error)
    • Flow count looks wrong: False
  • 243.9 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 243.10 Verify full connectivity for [u'h1', u'h2', u'h5'] with tag CASE243_Before - FAIL (error)
    • IP connectivity failed
  • 243.11 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 243.12 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 243.13 Check whether the flow count is bigger than 104 - PASS (tick)FAIL (error)
    • Flow count looks wrong: False
  • 243.14 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 243.15 Verify full connectivity for [u'h1', u'h2', u'h5'] with tag CASE243_After - FAIL (error)
    • IP connectivity failed
  • 243.16 Stopping Mininet - PASS (tick)
  • 243.17 Copying karaf logs - PASS (tick)