Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Published from Jenkins build: https://jenkins.onosproject.org/job/SR-pipeline-master/133/

...

HTML
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric4/lastSuccessfulBuild/artifact/SRBridging_master_20-builds_graph.jpg", alt="SRBridging", style="width:525px;height:350px;border:0">

commit 34af3168f472f717c7df6fe1948f87de68c909db b251801737d250b4c72264db6916d038b945ebfc (HEAD -] master, origin/master, origin/HEAD)
Author: Yi Tseng Andreas Pantelopoulos [yi@opennetworkingandreas@opennetworking.org]
AuthorDate: Sun Mon Jun 17 18 12:0250:21 35 2018 +0800-0700
Commit: Yi Tseng Charles Chan [yi@opennetworkingcharles@opennetworking.org]
CommitDate: Sun Mon Jun 17 18 20:0248:21 05 2018 +0800
Fix incorrect defined boolean value for fabric.p40000

Configuration option respondToUnknownHosts.
--
(cherry picked from commit 7bf9e441bdc4c7ac420f2a59e4d176005a40d020)

Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR and 3 ONOS instances - FAIL

...

  • 5.1 Constructing test variables - PASS (tick)
  • 5.2 Apply cell to environment - PASS (tick)
  • 5.3 Uninstalling ONOS package - PASS (tick)
  • 5.4 Creating ONOS package - PASS (tick)
  • 5.5 Installing ONOS package - PASS (tick)
  • 5.6 Set up ONOS secure SSH - PASS (tick)
  • 5.7 Checking ONOS service - PASS (tick)
  • 5.8 Starting ONOS CLI sessions - PASS (tick)
  • 5.9 Starting Mininet Topology - PASS (tick)
  • 5.10 Check whether the flow count is bigger than 28 - PASS (tick)FAIL (error)
    • Flow count looks wrong: False
  • 5.11 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • PASS (tick)
  • 5.12 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS (tick)
  • 5.13 Verify full connectivity for [u'h1', u'h2'] with tag CASE5 - PASS (tick)
  • 5.14 Stopping Mininet - PASS (tick)
  • 5.15 Copying karaf logs - PASS (tick)

...

  • 8.1 Apply cell to environment - PASS (tick)
  • 8.2 Uninstalling ONOS package - PASS (tick)
  • 8.3 Installing ONOS package - PASS (tick)
  • 8.4 Set up ONOS secure SSH - PASS (tick)
  • 8.5 Checking ONOS service - PASS (tick)
  • 8.6 Starting ONOS CLI sessions - PASS (tick)
  • 8.7 Starting Mininet Topology - PASS (tick)
  • 8.8 Check whether the flow count is bigger than 212 - FAIL (error)
  • Flow count looks wrong: False
  • PASS (tick)
  • 8.9 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 8.10 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 8.11 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 8.12 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS (tick)
  • 8.13 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS (tick)
  • 8.14 Verify full connectivity for [u'h1', u'h2'] with tag CASE8 - PASS (tick)
  • 8.15 Verify full connectivity for [u'h3', u'h4'] with tag CASE8 - PASS (tick)
  • 8.16 Stopping Mininet - PASS (tick)
  • 8.17 Copying karaf logs - PASS (tick)

...

  • 15.1 Apply cell to environment - PASS (tick)
  • 15.2 Uninstalling ONOS package - PASS (tick)
  • 15.3 Installing ONOS package - PASS (tick)
  • 15.4 Set up ONOS secure SSH - PASS (tick)
  • 15.5 Checking ONOS service - PASS (tick)
  • 15.6 Starting ONOS CLI sessions - PASS (tick)
  • 15.7 Starting Mininet Topology - PASS (tick)
  • 15.8 Check whether the flow count is bigger than 28 - FAIL (error)
  • Flow count looks wrong: False
  • PASS (tick)
  • 15.9 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 15.10 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS (tick)
  • 15.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE15 - PASS (tick)
  • 15.12 Stopping Mininet - PASS (tick)
  • 15.13 Copying karaf logs - PASS (tick)

...

  • 16.1 Apply cell to environment - PASS (tick)
  • 16.2 Uninstalling ONOS package - PASS (tick)
  • 16.3 Installing ONOS package - PASS (tick)
  • 16.4 Set up ONOS secure SSH - PASS (tick)
  • 16.5 Checking ONOS service - PASS (tick)
  • 16.6 Starting ONOS CLI sessions - PASS (tick)
  • 16.7 Starting Mininet Topology - PASS (tick)
  • 16.8 Check whether the flow count is bigger than 74 - FAIL (error)
  • Flow count looks wrong: False
  • PASS (tick)
  • 16.9 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 16.10 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 16.11 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 16.12 Verify full connectivity for [u'h1', u'h2'] with tag CASE16 - PASS (tick)
  • 16.13 Stopping Mininet - PASS (tick)
  • 16.14 Copying karaf logs - PASS (tick)

...

  • 18.1 Apply cell to environment - PASS (tick)
  • 18.2 Uninstalling ONOS package - PASS (tick)
  • 18.3 Installing ONOS package - PASS (tick)
  • 18.4 Set up ONOS secure SSH - PASS (tick)
  • 18.5 Checking ONOS service - PASS (tick)
  • 18.6 Starting ONOS CLI sessions - PASS (tick)
  • 18.7 Starting Mininet Topology - PASS (tick)
  • 18.8 Check whether the flow count is bigger than 212 - PASS (tick)FAIL (error)
    • Flow count looks wrong: False
  • 18.9 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 18.10 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 18.11 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 18.12 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS (tick)
  • 18.13 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS (tick)
  • 18.14 Verify full connectivity for [u'h1', u'h2'] with tag CASE18 - PASS (tick)
  • 18.15 Verify full connectivity for [u'h3', u'h4'] with tag CASE18 - PASS (tick)
  • 18.16 Stopping Mininet - PASS (tick)
  • 18.17 Copying karaf logs - PASS (tick)

...

  • 27.1 Apply cell to environment - PASS (tick)
  • 27.2 Uninstalling ONOS package - PASS (tick)
  • 27.3 Installing ONOS package - PASS (tick)
  • 27.4 Set up ONOS secure SSH - PASS (tick)
  • 27.5 Checking ONOS service - PASS (tick)
  • 27.6 Starting ONOS CLI sessions - PASS (tick)
  • 27.7 Starting Mininet Topology - PASS (tick)
  • 27.8 Check whether the flow count is bigger than 74 - FAIL (error)
  • Flow count looks wrong: False
  • PASS (tick)
  • 27.9 Check whether all flow status are ADDED - PASS (tick)FAIL (error)
    • Flow status is wrong!
  • 27.10 Check whether the flow count of device of:0000000000000001 is bigger than 37 - FAIL (error)
  • Flow count looks wrong.
  • PASS (tick)
  • 27.11 Check whether the flow count of device of:0000000000000002 is bigger than 37 - FAIL (error)
  • Flow count looks wrong.
  • PASS (tick)
  • 27.12 Verify full connectivity for [u'h1', u'h2'] with tag CASE27 - FAIL (error)
    • IP connectivity failed
  • PASS (tick)
  • 27.13 Verify full connectivity for [u'h3', u'h4'] with tag CASE27 - FAIL (error)
    • IP connectivity failed
  • PASS (tick)
  • 27.14 Stopping Mininet - PASS (tick)
  • 27.15 Copying karaf logs - PASS (tick)

...

  • 35.1 Apply cell to environment - PASS (tick)
  • 35.2 Uninstalling ONOS package - PASS (tick)
  • 35.3 Installing ONOS package - PASS (tick)
  • 35.4 Set up ONOS secure SSH - PASS (tick)
  • 35.5 Checking ONOS service - PASS (tick)
  • 35.6 Starting ONOS CLI sessions - PASS (tick)
  • 35.7 Starting Mininet Topology - PASS (tick)
  • 35.8 Check whether the flow count is bigger than 28 - FAIL (error)
    • Flow count looks wrong: False
  • 35.9 Check whether all flow status are ADDED - PASS (tick)FAIL (error)
    • Flow status is wrong!
  • 35.10 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS (tick)
  • 35.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE35 - PASS (tick)
  • 35.12 Stopping Mininet - PASS (tick)
  • 35.13 Copying karaf logs - PASS (tick)

...

  • 37.1 Apply cell to environment - PASS (tick)
  • 37.2 Uninstalling ONOS package - PASS (tick)
  • 37.3 Installing ONOS package - PASS (tick)
  • 37.4 Set up ONOS secure SSH - PASS (tick)
  • 37.5 Checking ONOS service - PASS (tick)
  • 37.6 Starting ONOS CLI sessions - PASS (tick)
  • 37.7 Starting Mininet Topology - PASS (tick)
  • 37.8 Check whether the flow count is bigger than 74 - FAIL (error)
    • Flow count looks wrong: False
  • PASS (tick)
  • 37.9 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 37.10 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 37.11 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 37.12 Verify full connectivity for [u'h1', u'h2'] with tag CASE37 - PASS (tick)
  • 37.13 Verify full connectivity for [u'h3', u'h4'] with tag CASE37 - PASS (tick)
  • 37.14 Stopping Mininet - PASS (tick)
  • 37.15 Copying karaf logs - PASS (tick)

...

  • 38.1 Apply cell to environment - PASS (tick)
  • 38.2 Uninstalling ONOS package - PASS (tick)
  • 38.3 Installing ONOS package - PASS (tick)
  • 38.4 Set up ONOS secure SSH - PASS (tick)
  • 38.5 Checking ONOS service - PASS (tick)
  • 38.6 Starting ONOS CLI sessions - PASS (tick)
  • 38.7 Starting Mininet Topology - PASS (tick)
  • 38.8 Check whether the flow count is bigger than 212 - FAIL (error)
  • Flow count looks wrong: False
  • PASS (tick)
  • 38.9 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 38.10 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 38.11 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 38.12 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS (tick)
  • 38.13 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS (tick)
  • 38.14 Verify full connectivity for [u'h1', u'h2'] with tag CASE38 - PASS (tick)
  • 38.15 Verify full connectivity for [u'h3', u'h4'] with tag CASE38 - PASS (tick)
  • 38.16 Stopping Mininet - PASS (tick)
  • 38.17 Copying karaf logs - PASS (tick)

...

  • 45.1 Apply cell to environment - PASS (tick)
  • 45.2 Uninstalling ONOS package - PASS (tick)
  • 45.3 Installing ONOS package - PASS (tick)
  • 45.4 Set up ONOS secure SSH - PASS (tick)
  • 45.5 Checking ONOS service - PASS (tick)
  • 45.6 Starting ONOS CLI sessions - PASS (tick)
  • 45.7 Starting Mininet Topology - PASS (tick)
  • 45.8 Check whether the flow count is bigger than 28 - FAIL (error)
  • Flow count looks wrong: False
  • PASS (tick)
  • 45.9 Check whether all flow status are ADDED - PASS (tick)FAIL (error)
    • Flow status is wrong!
  • 45.10 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS (tick)
  • 45.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE45 - PASS (tick)
  • 45.12 Stopping Mininet - PASS (tick)
  • 45.13 Copying karaf logs - PASS (tick)

...

  • 46.1 Apply cell to environment - PASS (tick)
  • 46.2 Uninstalling ONOS package - PASS (tick)
  • 46.3 Installing ONOS package - PASS (tick)
  • 46.4 Set up ONOS secure SSH - PASS (tick)
  • 46.5 Checking ONOS service - PASS (tick)
  • 46.6 Starting ONOS CLI sessions - PASS (tick)
  • 46.7 Starting Mininet Topology - PASS (tick)
  • 46.8 Check whether the flow count is bigger than 74 - PASS (tick)FAIL (error)
    • Flow count looks wrong: False
  • 46.9 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 46.10 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 46.11 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 46.12 Verify full connectivity for [u'h1', u'h2'] with tag CASE46 - PASS (tick)
  • 46.13 Stopping Mininet - PASS (tick)
  • 46.14 Copying karaf logs - PASS (tick)

...

  • 47.1 Apply cell to environment - PASS (tick)
  • 47.2 Uninstalling ONOS package - PASS (tick)
  • 47.3 Installing ONOS package - PASS (tick)
  • 47.4 Set up ONOS secure SSH - PASS (tick)
  • 47.5 Checking ONOS service - PASS (tick)
  • 47.6 Starting ONOS CLI sessions - PASS (tick)
  • 47.7 Starting Mininet Topology - PASS (tick)
  • 47.8 Check whether the flow count is bigger than 74 - PASS (tick)FAIL (error)
    • Flow count looks wrong: False
  • 47.9 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 47.10 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 47.11 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 47.12 Verify full connectivity for [u'h1', u'h2'] with tag CASE47 - PASS (tick)
  • 47.13 Verify full connectivity for [u'h3', u'h4'] with tag CASE47 - PASS (tick)
  • 47.14 Stopping Mininet - PASS (tick)
  • 47.15 Copying karaf logs - PASS (tick)

...

  • 55.1 Apply cell to environment - PASS (tick)
  • 55.2 Uninstalling ONOS package - PASS (tick)
  • 55.3 Installing ONOS package - PASS (tick)
  • 55.4 Set up ONOS secure SSH - PASS (tick)
  • 55.5 Checking ONOS service - PASS (tick)
  • 55.6 Starting ONOS CLI sessions - PASS (tick)
  • 55.7 Starting Mininet Topology - PASS (tick)
  • 55.8 Check whether the flow count is bigger than 28 - PASS (tick)FAIL (error)
    • Flow count looks wrong: False
  • 55.9 Check whether all flow status are ADDED - FAIL (error)
  • Flow status is wrong!
  • PASS (tick)
  • 55.10 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS (tick)
  • 55.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE55 - PASS (tick)
  • 55.12 Stopping Mininet - PASS (tick)
  • 55.13 Copying karaf logs - PASS (tick)

...

  • 56.1 Apply cell to environment - PASS (tick)
  • 56.2 Uninstalling ONOS package - PASS (tick)
  • 56.3 Installing ONOS package - PASS (tick)
  • 56.4 Set up ONOS secure SSH - PASS (tick)
  • 56.5 Checking ONOS service - PASS (tick)
  • 56.6 Starting ONOS CLI sessions - PASS (tick)
  • 56.7 Starting Mininet Topology - PASS (tick)
  • 56.8 Check whether the flow count is bigger than 74 - FAIL (error)
    • Flow count looks wrong: False
  • PASS (tick)
  • 56.9 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 56.10 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 56.11 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 56.12 Verify full connectivity for [u'h1', u'h2'] with tag CASE56 - PASS (tick)
  • 56.13 Stopping Mininet - PASS (tick)
  • 56.14 Copying karaf logs - PASS (tick)

...

  • 66.1 Apply cell to environment - PASS (tick)
  • 66.2 Uninstalling ONOS package - PASS (tick)
  • 66.3 Installing ONOS package - PASS (tick)
  • 66.4 Set up ONOS secure SSH - PASS (tick)
  • 66.5 Checking ONOS service - PASS (tick)
  • 66.6 Starting ONOS CLI sessions - PASS (tick)
  • 66.7 Starting Mininet Topology - PASS (tick)
  • 66.8 Check whether the flow count is bigger than 74 - FAIL (error)
  • Flow count looks wrong: False
  • PASS (tick)
  • 66.9 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 66.10 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 66.11 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 66.12 Verify full connectivity for [u'h1', u'h2'] with tag CASE66 - PASS (tick)
  • 66.13 Stopping Mininet - PASS (tick)
  • 66.14 Copying karaf logs - PASS (tick)

...

  • 67.1 Apply cell to environment - PASS (tick)
  • 67.2 Uninstalling ONOS package - PASS (tick)
  • 67.3 Installing ONOS package - PASS (tick)
  • 67.4 Set up ONOS secure SSH - PASS (tick)
  • 67.5 Checking ONOS service - PASS (tick)
  • 67.6 Starting ONOS CLI sessions - PASS (tick)
  • 67.7 Starting Mininet Topology - PASS (tick)
  • 67.8 Check whether the flow count is bigger than 74 - FAIL (error)
  • Flow count looks wrong: False
  • PASS (tick)
  • 67.9 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 67.10 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 67.11 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 67.12 Verify full connectivity for [u'h1', u'h2'] with tag CASE67 - PASS (tick)
  • 67.13 Verify full connectivity for [u'h3', u'h4'] with tag CASE67 - PASS (tick)
  • 67.14 Stopping Mininet - PASS (tick)
  • 67.15 Copying karaf logs - PASS (tick)

...

  • 76.1 Apply cell to environment - PASS (tick)
  • 76.2 Uninstalling ONOS package - PASS (tick)
  • 76.3 Installing ONOS package - PASS (tick)
  • 76.4 Set up ONOS secure SSH - PASS (tick)
  • 76.5 Checking ONOS service - PASS (tick)
  • 76.6 Starting ONOS CLI sessions - PASS (tick)
  • 76.7 Starting Mininet Topology - PASS (tick)
  • 76.8 Check whether the flow count is bigger than 74 - PASS (tick)FAIL (error)
    • Flow count looks wrong: False
  • 76.9 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 76.10 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 76.11 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 76.12 Verify full connectivity for [u'h1', u'h2'] with tag CASE76 - PASS (tick)
  • 76.13 Stopping Mininet - PASS (tick)
  • 76.14 Copying karaf logs - PASS (tick)

...

  • 78.1 Apply cell to environment - PASS (tick)
  • 78.2 Uninstalling ONOS package - PASS (tick)
  • 78.3 Installing ONOS package - PASS (tick)
  • 78.4 Set up ONOS secure SSH - PASS (tick)
  • 78.5 Checking ONOS service - PASS (tick)
  • 78.6 Starting ONOS CLI sessions - PASS (tick)
  • 78.7 Starting Mininet Topology - PASS (tick)
  • 78.8 Check whether the flow count is bigger than 212 - PASS (tick)FAIL (error)
    • Flow count looks wrong: False
  • 78.9 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 78.10 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 78.11 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 78.12 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS (tick)
  • 78.13 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS (tick)
  • 78.14 Verify full connectivity for [u'h1', u'h2'] with tag CASE78 - PASS (tick)
  • 78.15 Verify full connectivity for [u'h3', u'h4'] with tag CASE78 - PASS (tick)
  • 78.16 Stopping Mininet - PASS (tick)
  • 78.17 Copying karaf logs - PASS (tick)