  • 27.1 Apply cell to environment - PASS (tick)
  • 27.2 Uninstalling ONOS package - PASS (tick)
  • 27.3 Installing ONOS package - PASS (tick)
  • 27.4 Set up ONOS secure SSH - PASS (tick)
  • 27.5 Checking ONOS service - PASS (tick)
  • 27.6 Starting ONOS CLI sessions - PASS (tick)
  • 27.7 Starting Mininet Topology - PASS (tick)
  • 27.8 Check whether the flow count is bigger than 74 - PASS (tick)
  • 27.9 Check whether all flow status are ADDED - PASS (tick)
  • 27.10 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 27.11 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 27.12 Verify full connectivity for [u'h1', u'h2'] with tag CASE27 - PASS (tick)
  • 27.13 Verify full connectivity for [u'h3', u'h4'] with tag CASE27 - PASS (tick)
  • 27.14 Stopping Mininet - PASS (tick)
  • 27.15 Copying karaf logs - PASS (tick)

Case 28: Bridging test between two untagged hosts on vlan-native port, with 2x4 dual-homed leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 28.1 Apply cell to environment - PASS (tick)
  • 28.2 Uninstalling ONOS package - PASS (tick)
  • 28.3 Installing ONOS package - PASS (tick)
  • 28.4 Set up ONOS secure SSH - PASS (tick)
  • 28.5 Checking ONOS service - PASS (tick)
  • 28.6 Starting ONOS CLI sessions - PASS (tick)
  • 28.7 Starting Mininet Topology - PASS (tick)
  • 28.8 Check whether the flow count is bigger than 212 - PASS (tick)
  • 28.9 Check whether all flow status are ADDED - PASS (tick)
  • 28.10 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)FAIL (error)
    • Flow count looks wrong.
  • 28.11 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 28.12 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS (tick)
  • 28.13 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS (tick)FAIL (error)
    • Flow count looks wrong.
  • 28.14 Verify full connectivity for [u'h1', u'h2'] with tag CASE28 - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 28.15 Verify full connectivity for [u'h3', u'h4'] with tag CASE28 - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 28.16 Stopping Mininet - PASS (tick)
  • 28.17 Copying karaf logs - PASS (tick)

...

  • 46.1 Apply cell to environment - PASS (tick)
  • 46.2 Uninstalling ONOS package - PASS (tick)
  • 46.3 Installing ONOS package - PASS (tick)
  • 46.4 Set up ONOS secure SSH - PASS (tick)
  • 46.5 Checking ONOS service - PASS (tick)
  • 46.6 Starting ONOS CLI sessions - PASS (tick)
  • 46.7 Starting Mininet Topology - PASS (tick)
  • 46.8 Check whether the flow count is bigger than 74 - PASS (tick)
  • 46.9 Check whether all flow status are ADDED - PASS (tick)
  • 46.10 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 46.11 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 46.12 Verify full connectivity for [u'h1', u'h2'] with tag CASE46 - PASS (tick)
  • 46.13 Stopping Mininet - PASS (tick)
  • 46.14 Copying karaf logs - PASS (tick)

Case 47: Bridging test between untagged host and tagged host, with 2x2 leaf-spine topology and 3 ONOS instances -

...

PASS

  • 47.1 Apply cell to environment - PASS (tick)
  • 47.2 Uninstalling ONOS package - PASS (tick)
  • 47.3 Installing ONOS package - PASS (tick)
  • 47.4 Set up ONOS secure SSH - PASS (tick)
  • 47.5 Checking ONOS service - PASS (tick)
  • 47.6 Starting ONOS CLI sessions - PASS (tick)
  • 47.7 Starting Mininet Topology - PASS (tick)
  • 47.8 Check whether the flow count is bigger than 74 - PASS (tick)
  • 47.9 Check whether all flow status are ADDED - PASS (tick)
  • 47.10 Check whether the flow count of device of:0000000000000001 is bigger than 37 - FAIL (error)
    • Flow count looks wrong.
  • PASS (tick)
  • 47.11 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 47.12 Verify full connectivity for [u'h1', u'h2'] with tag CASE47 - FAIL (error)
    • IP connectivity failed
  • PASS (tick)
  • 47.13 Verify full connectivity for [u'h3', u'h4'] with tag CASE47 - PASS (tick)
  • 47.14 Stopping Mininet - PASS (tick)
  • 47.15 Copying karaf logs - PASS (tick)

...

  • 55.1 Apply cell to environment - PASS (tick)
  • 55.2 Uninstalling ONOS package - PASS (tick)
  • 55.3 Installing ONOS package - PASS (tick)
  • 55.4 Set up ONOS secure SSH - PASS (tick)
  • 55.5 Checking ONOS service - PASS (tick)
  • 55.6 Starting ONOS CLI sessions - PASS (tick)
  • 55.7 Starting Mininet Topology - PASS (tick)
  • 55.8 Check whether the flow count is bigger than 28 - PASS (tick)
  • 55.9 Check whether all flow status are ADDED - PASS (tick)
  • 55.10 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS (tick)
  • 55.11 Verify full connectivity for [u'h1', u'h2'] with tag CASE55 - PASS (tick)
  • 55.12 Stopping Mininet - PASS (tick)
  • 55.13 Copying karaf logs - PASS (tick)

Case 56: Bridging test between two untagged hosts with different vlan id, with dual-homed ToR and 3 ONOS instances -

...

PASS

  • 56.1 Apply cell to environment - PASS (tick)
  • 56.2 Uninstalling ONOS package - PASS (tick)
  • 56.3 Installing ONOS package - PASS (tick)
  • 56.4 Set up ONOS secure SSH - PASS (tick)
  • 56.5 Checking ONOS service - PASS (tick)
  • 56.6 Starting ONOS CLI sessions - PASS (tick)
  • 56.7 Starting Mininet Topology - PASS (tick)
  • 56.8 Check whether the flow count is bigger than 74 - FAIL (error)
    • Flow count looks wrong: False
  • PASS (tick)
  • 56.9 Check whether all flow status are ADDED - PASS (tick)
  • 56.10 Check whether the flow count of device of:0000000000000001 is bigger than 37 - FAIL (error)
  • Flow count looks wrong.
  • PASS (tick)
  • 56.11 Check whether the flow count of device of:0000000000000002 is bigger than 37 - FAIL (error)
  • Flow count looks wrong.
  • PASS (tick)
  • 56.12 Verify full connectivity for [u'h1', u'h2'] with tag CASE56 - PASS (tick)
  • 56.13 Stopping Mininet - PASS (tick)
  • 56.14 Copying karaf logs - PASS (tick)

...