Due to a ransomware attack, the wiki was reverted to a July 2022 version. . We apologize for the lack of a more recent valid backup.
...
HTML |
---|
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric4/lastSuccessfulBuild/artifact/SRBridging_master_20-builds_graph.jpg", alt="SRBridging", style="width:525px;height:350px;border:0"> |
commit 577b69c94589ef8a489397b97e2fb63778e07273 58136816ab8654b7e16634b1cf4899844f10f9e1 (HEAD -] master, origin/master, origin/HEAD)
Author: Daniel Park Carmelo Cascone [dancarmelo@opennetworking.mcpark84@gmail.comorg]
AuthorDate: Mon Thu Jul 16 1719 03:2940:34 16 2018 +09000200
Commit: Jian Li Carmelo Cascone [pyguni@gmailcarmelo@opennetworking.comorg]
CommitDate: Fri Jul 20 0118:3916:19 17 2018 +0000
Implements flow tracer in Openstack Networking UI
ONOS-7739 Support for P4Runtime multicast programming
Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR and 3 ONOS instances - PASS
...
- 56.1 Apply cell to environment - PASS
- 56.2 Uninstalling ONOS package - PASS
- 56.3 Installing ONOS package - PASS
- 56.4 Set up ONOS secure SSH - PASS
- 56.5 Checking ONOS service - PASS
- 56.6 Starting ONOS CLI sessions - PASS
- 56.7 Starting Mininet Topology - PASS
- 56.8 Check whether the flow count is bigger than 74 - PASS
- 56.9 Check whether all flow status are ADDED - PASS
- 56.10 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 56.11 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 56.12 Verify full connectivity for [u'h1', u'h2'] with tag CASE56 - PASS
- 56.13 Stopping Mininet - PASS
- 56.14 Copying karaf logs - PASS
Case 57: Bridging test between two untagged hosts with different vlan id, with 2x2 leaf-spine topology and 3 ONOS instances -
...
FAIL
- 57.1 Apply cell to environment - PASS
- 57.2 Uninstalling ONOS package - PASS
- 57.3 Installing ONOS package - PASS
- 57.4 Set up ONOS secure SSH - PASS
- 57.5 Checking ONOS service - PASS
- 57.6 Starting ONOS CLI sessions - PASS
- 57.7 Starting Mininet Topology - PASS
- 57.8 Check whether the flow count is bigger than 74 - PASS
- 57.9 Check whether all flow status are ADDED - PASS
- 57.10 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 57.11 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
FAIL
- Flow count looks wrong.
- 57.12 Verify full connectivity for [u'h1', u'h2'] with tag CASE57 - PASS
- 57.13 Verify full connectivity for [u'h3', u'h4'] with tag CASE57 - PASS
- 57.14 Stopping Mininet - PASS
- 57.15 Copying karaf logs - PASS
...