Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Published from Jenkins build: https://jenkins.onosproject.org/job/SR-pipeline-master/165/

...

HTML
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric4/lastSuccessfulBuild/artifact/SRBridging_master_20-builds_graph.jpg", alt="SRBridging", style="width:525px;height:350px;border:0">

commit 4f6ba532ec5e0df3991351da8c106eef527fb350 da03ce9d721662631ee567d6dec1f99515ffce85 (HEAD -] master, origin/master, origin/HEAD)
Author: Thomas Vachuska Jian Li [tom@opennetworkingpyguni@gmail.orgcom]
AuthorDate: Tue Jul 24 1221:5941:20 53 2018 -0700+0900
Commit: Thomas Vachuska Jian Li [tom@opennetworkingpyguni@gmail.orgcom]
CommitDate: Tue Thu Jul 24 1226 02:5905:48 35 2018 -0700
Small fix to onos-publish-artifacts.py+0000

Fix: resolve a set of exceptions raised by tempest integration test

Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR and 3 ONOS instances - PASS

...

  • 77.1 Apply cell to environment - PASS (tick)
  • 77.2 Uninstalling ONOS package - PASS (tick)
  • 77.3 Installing ONOS package - PASS (tick)
  • 77.4 Set up ONOS secure SSH - PASS (tick)
  • 77.5 Checking ONOS service - PASS (tick)
  • 77.6 Starting ONOS CLI sessions - PASS (tick)
  • 77.7 Starting Mininet Topology - PASS (tick)
  • 77.8 Check whether the flow count is bigger than 74 - PASS (tick)
  • 77.9 Check whether all flow status are ADDED - PASS (tick)
  • 77.10 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 77.11 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 77.12 Verify full connectivity for [u'h1', u'h2'] with tag CASE77 - PASS (tick)
  • 77.13 Verify full connectivity for [u'h3', u'h4'] with tag CASE77 - PASS (tick)
  • 77.14 Stopping Mininet - PASS (tick)
  • 77.15 Copying karaf logs - PASS (tick)

Case 78: Bridging test between untagged and tagged hosts with different vlan id, with 2x4 dual-homed leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 78.1 Apply cell to environment - PASS (tick)
  • 78.2 Uninstalling ONOS package - PASS (tick)
  • 78.3 Installing ONOS package - PASS (tick)
  • 78.4 Set up ONOS secure SSH - PASS (tick)
  • 78.5 Checking ONOS service - PASS (tick)
  • 78.6 Starting ONOS CLI sessions - PASS (tick)
  • 78.7 Starting Mininet Topology - PASS (tick)
  • 78.8 Check whether the flow count is bigger than 212 - PASS (tick)
  • 78.9 Check whether all flow status are ADDED - PASS (tick)
  • 78.10 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 78.11 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 78.12 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS (tick)
  • 78.13 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS (tick)FAIL (error)
    • Flow count looks wrong.
  • 78.14 Verify full connectivity for [u'h1', u'h2'] with tag CASE78 - PASS (tick)
  • 78.15 Verify full connectivity for [u'h3', u'h4'] with tag CASE78 - PASS (tick)
  • 78.16 Stopping Mininet - PASS (tick)
  • 78.17 Copying karaf logs - PASS (tick)