Due to a ransomware attack, the wiki was reverted to a July 2022 version. . We apologize for the lack of a more recent valid backup.
...
HTML |
---|
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric3/lastSuccessfulBuild/artifact/SRBridging_onos-2.2_20-builds_graph.jpg", alt="SRBridging", style="width:525px;height:350px;border:0"> |
commit 70782fc05fab40e77134fdc460f1613394528246 fe3a90500f1d26dd1298d792f6601c7636ff25c2 (HEAD -] onos-2.2, origin/onos-2.2)
Author: pierventre Jian Li [pier@opennetworkingpyguni@gmail.orgcom]
AuthorDate: Wed Apr 21 Tue May 11 18:12:57:47 55 2021 +02000900
Commit: Pier Luigi Ventre [pier@opennetworking.orgJian Li [pyguni@gmail.com]
CommitDate: Fri Apr 30 04:33:23 2021 +0000
[AETHER-1550] Add additional trace logs in P4RT SBTue May 11 18:25:07 2021 +0900
Fix: support Container Network Addons (CNA) operator from kubevirt
Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR, ovs switches and 3 ONOS instances -
...
PASS
- 5.1 Constructing test variables - PASS
- 5.2 Apply cell to environment - PASS
- 5.3 Uninstalling Atomix - PASS
- 5.4 Uninstalling ONOS package - PASS
- 5.5 Creating ONOS package - PASS
- 5.6 Installing Atomix - PASS
- 5.7 Installing ONOS package - PASS
- 5.8 Set up ONOS secure SSH - PASS
- 5.9 Checking ONOS service - PASS
- 5.10 Starting ONOS CLI sessions - PASS
- 5.11 Checking ONOS nodes - PASS
- 5.12 Checking ONOS applications - PASS
- 5.13 Set logging levels - PASS
- 5.14 Set ONOS configurations - PASS
- 5.15 Starting Mininet Topology - PASS
- 5.16 Check whether the flow count is >= 28 - FAIL Flow count looks wrong; found 17, expecting at least 28
- PASS
- 5.17 Check whether all flow status are ADDED - PASS
- 5.18 Check whether the flow count of device of:0000000000000001 >= than 28 - FAIL Flow count looks wrong: 17
- PASS
- 5.19 Check number of topology elements - PASS
- 5.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE5 - FAIL
- IP connectivity failed
- PASS
- 5.21 Stopping Mininet - PASS
- 5.22 Copying karaf logs - PASS
...
- 6.1 Apply cell to environment - PASS
- 6.2 Uninstalling Atomix - PASS
- 6.3 Uninstalling ONOS package - PASS
- 6.4 Installing Atomix - PASS
- 6.5 Installing ONOS package - PASS
- 6.6 Set up ONOS secure SSH - PASS
- 6.7 Checking ONOS service - PASS
- 6.8 Starting ONOS CLI sessions - PASS
- 6.9 Checking ONOS nodes - PASS
- 6.10 Checking ONOS applications - PASS
- 6.11 Set logging levels - PASS
- 6.12 Set ONOS configurations - PASS
- 6.13 Starting Mininet Topology - PASS
- 6.14 Check whether the flow count is >= 74 - PASS
- 6.15 Check whether all flow status are ADDED - PASS
- 6.16 Check whether the flow count of device of:0000000000000001 >= than 37 - PASS
- 6.17 Check whether the flow count of device of:0000000000000002 >= than 37 - PASS
- 6.18 Check number of topology elements - PASS
- 6.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE6 - PASS
- 6.20 Stopping Mininet - PASS
- 6.21 Copying karaf logs - PASS
Case 7: Bridging test between two untagged hosts on vlan-untagged port, with 2x2 leaf-spine topology, ovs switches and 3 ONOS instances -
...
FAIL
- 7.1 Apply cell to environment - PASS
- 7.2 Uninstalling Atomix - PASS
- 7.3 Uninstalling ONOS package - PASS
- 7.4 Installing Atomix - PASS
- 7.5 Installing ONOS package - PASS
- 7.6 Set up ONOS secure SSH - PASS
- 7.7 Checking ONOS service - PASS
- 7.8 Starting ONOS CLI sessions - PASS
- 7.9 Checking ONOS nodes - PASS
- 7.10 Checking ONOS applications - PASS
- 7.11 Set logging levels - PASS
- 7.12 Set ONOS configurations - PASS
- 7.13 Starting Mininet Topology - PASS
- 7.14 Check whether the flow count is >= 74 - PASS
- 7.15 Check whether all flow status are ADDED - PASS
- 7.16 Check whether the flow count of device of:0000000000000001 >= than 37 - PASS
- 7.17 Check whether the flow count of device of:0000000000000002 >= than 37 - PASS FAIL
- Flow count looks wrong: 18
- 7.18 Check number of topology elements - PASS
- 7.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE7 - PASS
- 7.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE7 - PASS FAIL
- IP connectivity failed
- 7.21 Stopping Mininet - PASS
- 7.22 Copying karaf logs - PASS
...
- 15.1 Apply cell to environment - PASS
- 15.2 Uninstalling Atomix - PASS
- 15.3 Uninstalling ONOS package - PASS
- 15.4 Installing Atomix - PASS
- 15.5 Installing ONOS package - PASS
- 15.6 Set up ONOS secure SSH - PASS
- 15.7 Checking ONOS service - PASS
- 15.8 Starting ONOS CLI sessions - PASS
- 15.9 Checking ONOS nodes - PASS
- 15.10 Checking ONOS applications - PASS
- 15.11 Set logging levels - PASS
- 15.12 Set ONOS configurations - PASS
- 15.13 Starting Mininet Topology - PASS
- 15.14 Check whether the flow count is >= 28 - FAIL
- Flow count looks wrong; found 18, expecting at least 28
- 15.15 Check whether all flow status are ADDED - PASS
- 15.16 Check whether the flow count of device of:0000000000000001 >= than 28 - FAIL
- Flow count looks wrong: 18
- 15.17 Check number of topology elements - PASS
- 15.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE15 - FAIL
- IP connectivity failed
- 15.19 Stopping Mininet - PASS
- 15.20 Copying karaf logs - PASS
Case 16: Bridging test between two tagged hosts, with dual-homed ToR, ovs switches and 3 ONOS instances -
...
PASS
- 16.1 Apply cell to environment - PASS
- 16.2 Uninstalling Atomix - PASS
- 16.3 Uninstalling ONOS package - PASS
- 16.4 Installing Atomix - PASS
- 16.5 Installing ONOS package - PASS
- 16.6 Set up ONOS secure SSH - PASS
- 16.7 Checking ONOS service - PASS
- 16.8 Starting ONOS CLI sessions - PASS
- 16.9 Checking ONOS nodes - PASS
- 16.10 Checking ONOS applications - PASS
- 16.11 Set logging levels - PASS
- 16.12 Set ONOS configurations - PASS
- 16.13 Starting Mininet Topology - PASS
- 16.14 Check whether the flow count is >= 74 - PASS
- 16.15 Check whether all flow status are ADDED - PASS
- 16.16 Check whether the flow count of device of:0000000000000001 >= than 37 - FAIL
- Flow count looks wrong: 21
- PASS
- 16.17 Check whether the flow count of device of:0000000000000002 >= than 37 - PASS
- 16.18 Check number of topology elements - PASS
- 16.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE16 - FAIL
- IP connectivity failed
- PASS
- 16 16.20 Stopping Mininet - PASS
- 16.21 Copying karaf logs - PASS
Case 17: Bridging test between two tagged hosts, with 2x2 leaf-spine topology, ovs switches and 3 ONOS instances -
...
FAIL
- 17.1 Apply cell to environment - PASS
- 17.2 Uninstalling Atomix - PASS
- 17.3 Uninstalling ONOS package - PASS
- 17.4 Installing Atomix - PASS
- 17.5 Installing ONOS package - PASS
- 17.6 Set up ONOS secure SSH - PASS
- 17.7 Checking ONOS service - PASS
- 17.8 Starting ONOS CLI sessions - PASS
- 17.9 Checking ONOS nodes - PASS
- 17.10 Checking ONOS applications - PASS
- 17.11 Set logging levels - PASS
- 17.12 Set ONOS configurations - PASS
- 17.13 Starting Mininet Topology - PASS
- 17.14 Check whether the flow count is >= 74 - PASS
- 17.15 Check whether all flow status are ADDED - PASS
- 17.16 Check whether the flow count of device of:0000000000000001 >= than 37 - PASS
- 17.17 Check whether the flow count of device of:0000000000000002 >= than 37 - PASS
- 17.18 Check number of topology elements - PASS
- 17.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE17 - PASS FAIL
- IP connectivity failed
- 17.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE17 - PASS
- 17.21 Stopping Mininet - PASS
- 17.22 Copying karaf logs - PASS
...
- 26.1 Apply cell to environment - PASS
- 26.2 Uninstalling Atomix - PASS
- 26.3 Uninstalling ONOS package - PASS
- 26.4 Installing Atomix - PASS
- 26.5 Installing ONOS package - PASS
- 26.6 Set up ONOS secure SSH - PASS
- 26.7 Checking ONOS service - PASS
- 26.8 Starting ONOS CLI sessions - PASS
- 26.9 Checking ONOS nodes - PASS
- 26.10 Checking ONOS applications - PASS
- 26.11 Set logging levels - PASS
- 26.12 Set ONOS configurations - PASS
- 26.13 Starting Mininet Topology - PASS
- 26.14 Check whether the flow count is >= 74 - FAIL
- Flow count looks wrong; found 36, expecting at least 74
- 26.15 Check whether all flow status are ADDED - PASS
- 26.16 Check whether the flow count of device of:0000000000000001 >= than 37 - FAIL
- Flow count looks wrong: 18
- 26.17 Check whether the flow count of device of:0000000000000002 >= than 37 - FAIL
- Flow count looks wrong: 18
- 26.18 Check number of topology elements - PASS
- 26.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE26 - FAIL
- IP connectivity failed
- 26.20 Stopping Mininet - PASS
- 26.21 Copying karaf logs - PASS
Case 27: Bridging test between two untagged hosts on vlan-native port, with 2x2 leaf-spine topology, ovs switches and 3 ONOS instances -
...
FAIL
- 27.1 Apply cell to environment - PASS
- 27.2 Uninstalling Atomix - PASS
- 27.3 Uninstalling ONOS package - PASS
- 27.4 Installing Atomix - PASS
- 27.5 Installing ONOS package - PASS
- 27.6 Set up ONOS secure SSH - PASS
- 27.7 Checking ONOS service - PASS
- 27.8 Starting ONOS CLI sessions - PASS
- 27.9 Checking ONOS nodes - PASS
- 27.10 Checking ONOS applications - PASS
- 27.11 Set logging levels - PASS
- 27.12 Set ONOS configurations - PASS
- 27.13 Starting Mininet Topology - PASS
- 27.14 Check whether the flow count is >= 74 - PASS FAIL
- Flow count looks wrong; found 72, expecting at least 74
- 27.15 Check whether all flow status are ADDED - PASS
- 27.16 Check whether the flow count of device of:0000000000000001 >= than 37 - PASS FAIL
- Flow count looks wrong: 18
- 27.17 Check whether the flow count of device of:0000000000000002 >= than 37 - PASS FAIL
- Flow count looks wrong: 18
- 27.18 Check number of topology elements - PASS
- 27.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE27 - PASS FAIL
- IP connectivity failed
- 27.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE27 - PASS FAIL
- IP connectivity failed
- 27.21 Stopping Mininet - PASS
- 27.22 Copying karaf logs - PASS
...
Case 35: Bridging test between two untagged hosts, one on vlan-untagged port and the other on vlan-native port, with single ToR, ovs switches and 3 ONOS instances - FAIL
- 35.1 Apply cell to environment - PASS
- 35.2 Uninstalling Atomix - PASS
- 35.3 Uninstalling ONOS package - PASS
- 35.4 Installing Atomix - PASS
- 35.5 Installing ONOS package - PASS
- 35.6 Set up ONOS secure SSH - PASS
- 35.7 Checking ONOS service - PASS
- 35.8 Starting ONOS CLI sessions - PASS
- 35.9 Checking ONOS nodes - PASS
- 35.10 Checking ONOS applications - PASS
- 35.11 Set logging levels - PASS
- 35.12 Set ONOS configurations - PASS
- 35.13 Starting Mininet Topology - PASS
- 35.14 Check whether the flow count is >= 28 - FAIL
- Flow count looks wrong; found 18, expecting at least 28
- 35.15 Check whether all flow status are ADDED - PASS
- 35.16 Check whether the flow count of device of:0000000000000001 >= than 28 - FAIL
- Flow count looks wrong: 18
- 35.17 Check number of topology elements - PASS
- 35.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE35 - FAIL
- IP connectivity failed
- 35.19 Stopping Mininet - PASS
- 35.20 Copying karaf logs - PASS
Case 36: Bridging test between two untagged hosts, one on vlan-untagged port and the other on vlan-native port, with dual-homed ToR, ovs switches and 3 ONOS instances - PASS
- 36.1 Apply cell to environment - PASS
- 36.2 Uninstalling Atomix - PASS
- 36.3 Uninstalling ONOS package - PASS
- 36.4 Installing Atomix - PASS
- 36.5 Installing ONOS package - PASS
- 36.6 Set up ONOS secure SSH - PASS
- 36.7 Checking ONOS service - PASS
- 36.8 Starting ONOS CLI sessions - PASS
- 36.9 Checking ONOS nodes - PASS
- 36.10 Checking ONOS applications - PASS
- 36.11 Set logging levels - PASS
- 36.12 Set ONOS configurations - PASS
- 36.13 Starting Mininet Topology - PASS
- 36.14 Check whether the flow count is >= 74 - PASS
- 36.15 Check whether all flow status are ADDED - PASS
- 36.16 Check whether the flow count of device of:0000000000000001 >= than 37 - PASS
- 36.17 Check whether the flow count of device of:0000000000000002 >= than 37 - PASS
- 36.18 Check number of topology elements - PASS
- 36.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE36 - PASS
- 36.20 Stopping Mininet - PASS
- 36.21 Copying karaf logs - PASS
Case 37: Bridging test between two untagged hosts, one on vlan-untagged port and the other on vlan-native port, with 2x2 leaf-spine topology, ovs switches and 3 ONOS instances - PASS
- 37.1 Apply cell to environment - PASS
- 37.2 Uninstalling Atomix - PASS
- 37.3 Uninstalling ONOS package - PASS
- 37.4 Installing Atomix - PASS
- 37.5 Installing ONOS package - PASS
- 37.6 Set up ONOS secure SSH - PASS
- 37.7 Checking ONOS service - PASS
- 37.8 Starting ONOS CLI sessions - PASS
- 37.9 Checking ONOS nodes - PASS
- 37.10 Checking ONOS applications - PASS
- 37.11 Set logging levels - PASS
- 37.12 Set ONOS configurations - PASS
- 37.13 Starting Mininet Topology - PASS
- 37.14 Check whether the flow count is >= 74 - PASS
- 37.15 Check whether all flow status are ADDED - PASS
- 37.16 Check whether the flow count of device of:0000000000000001 >= than 37 - PASS
- 37.17 Check whether the flow count of device of:0000000000000002 >= than 37 - PASS
- 37.18 Check number of topology elements - PASS
- 37.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE37 - PASS
- 37.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE37 - PASS
- 37.21 Stopping Mininet - PASS
- 37.22 Copying karaf logs - PASS
Case 38: Bridging test between two untagged hosts, one on vlan-untagged port and the other on vlan-native port, with 2x4 dual-homed leaf-spine topology, ovs switches and 3 ONOS instances - FAIL
- 38.1 Apply cell to environment - PASS
- 38.2 Uninstalling Atomix - PASS
- 38.3 Uninstalling ONOS package - PASS
- 38.4 Installing Atomix - PASS
- 38.5 Installing ONOS package - PASS
- 38.6 Set up ONOS secure SSH - PASS
- 38.7 Checking ONOS service - PASS
- 38.8 Starting ONOS CLI sessions - PASS
- 38.9 Checking ONOS nodes - PASS
- 38.10 Checking ONOS applications - PASS
- 38.11 Set logging levels - PASS
- 38.12 Set ONOS configurations - PASS
- 38.13 Starting Mininet Topology - PASS
- 38.14 Check whether the flow count is >= 212 - PASS
- 38.15 Check whether all flow status are ADDED - PASS
- 38.16 Check whether the flow count of device of:0000000000000001 >= than 53 - PASS
- 38.17 Check whether the flow count of device of:0000000000000002 >= than 53 - PASS
- 38.18 Check whether the flow count of device of:0000000000000003 >= than 53 - PASS
- 38.19 Check whether the flow count of device of:0000000000000004 >= than 53 - PASS
- 38.20 Check number of topology elements - FAIL
- Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
- ONOS sees 6 devices (6 expected) and 36 links (38 expected) and 3 controllers (3 expected) and 1 SCCs (1 expected)
- 38.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE38 - PASS
- 38.22 Verify full connectivity for [u'h3', u'h4'] with tag CASE38 - PASS
- 38.23 Stopping Mininet - PASS
- 38.24 Copying karaf logs - PASS
Case 45: Bridging test between untagged host and tagged host, with single ToR, ovs switches and 3 ONOS instances - PASS
- 45.1 Apply cell to environment - PASS
- 45.2 Uninstalling Atomix - PASS
- 45.3 Uninstalling ONOS package - PASS
- 45.4 Installing Atomix - PASS
- 45.5 Installing ONOS package - PASS
- 45.6 Set up ONOS secure SSH - PASS
- 45.7 Checking ONOS service - PASS
- 45.8 Starting ONOS CLI sessions - PASS
- 45.9 Checking ONOS nodes - PASS
- 45.10 Checking ONOS applications - PASS
- 45.11 Set logging levels - PASS
- 45.12 Set ONOS configurations - PASS
- 45.13 Starting Mininet Topology - PASS
- 45.14 Check whether the flow count is >= 28 - PASS
- 45.15 Check whether all flow status are ADDED - PASS
- 45.16 Check whether the flow count of device of:0000000000000001 >= than 28 - PASS
- 45.17 Check number of topology elements - PASS
- 45.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE45 - PASS
- 45.19 Stopping Mininet - PASS
- 45.20 Copying karaf logs - PASS
Case 46: Bridging test between untagged host and tagged host, with dual-homed ToR, ovs switches and 3 ONOS instances - FAIL
- 46.1 Apply cell to environment - PASS
- 46.2 Uninstalling Atomix - PASS
- 46.3 Uninstalling ONOS package - PASS
- 46.4 Installing Atomix - PASS
- 46.5 Installing ONOS package - PASS
- 46.6 Set up ONOS secure SSH - PASS
- 46.7 Checking ONOS service - PASS
- 46.8 Starting ONOS CLI sessions - PASS
- 46.9 Checking ONOS nodes - PASS
- 46.10 Checking ONOS applications - PASS
- 46.11 Set logging levels - PASS
- 46.12 Set ONOS configurations - PASS
- 46.13 Starting Mininet Topology - PASS
- 46.14 Check whether the flow count is >= 74 - FAIL
- Flow count looks wrong; found 36, expecting at least 74
- 46.15 Check whether all flow status are ADDED - PASS
- 46.16 Check whether the flow count of device of:0000000000000001 >= than 37 - FAIL
- Flow count looks wrong: 18
- 46.17 Check whether the flow count of device of:0000000000000002 >= than 37 - FAIL
- Flow count looks wrong: 18
- 46.18 Check number of topology elements - PASS
- 46.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE46 - FAIL
- IP connectivity failed
- 46.20 Stopping Mininet - PASS
- 46.21 Copying karaf logs - PASS
Case 47: Bridging test between untagged host and tagged host, with 2x2 leaf-spine topology, ovs switches and 3 ONOS instances - PASS
- 47.1 Apply cell to environment - PASS
- 47.2 Uninstalling Atomix - PASS
- 47.3 Uninstalling ONOS package - PASS
- 47.4 Installing Atomix - PASS
- 47.5 Installing ONOS package - PASS
- 47.6 Set up ONOS secure SSH - PASS
- 47.7 Checking ONOS service - PASS
- 47.8 Starting ONOS CLI sessions - PASS
- 47.9 Checking ONOS nodes - PASS
- 47.10 Checking ONOS applications - PASS
- 47.11 Set logging levels - PASS
- 47.12 Set ONOS configurations - PASS
- 47.13 Starting Mininet Topology - PASS
- 47.14 Check whether the flow count is >= 74 - PASS
- 47.15 Check whether all flow status are ADDED - PASS
- 47.16 Check whether the flow count of device of:0000000000000001 >= than 37 - PASS
- 47.17 Check whether the flow count of device of:0000000000000002 >= than 37 - PASS
- 47.18 Check number of topology elements - PASS
- 47.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE47 - PASS
- 47.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE47 - PASS
- 47.21 Stopping Mininet - PASS
- 47.22 Copying karaf logs - PASS
Case 48: Bridging test between untagged host and tagged host, with 2x4 dual-homed leaf-spine topology, ovs switches and 3 ONOS instances - FAIL
- 48.1 Apply cell to environment - PASS
- 48.2 Uninstalling Atomix - PASS
- 48.3 Uninstalling ONOS package - PASS
- 48.4 Installing Atomix - PASS
- 48.5 Installing ONOS package - PASS
- 48.6 Set up ONOS secure SSH - PASS
- 48.7 Checking ONOS service - PASS
- 48.8 Starting ONOS CLI sessions - PASS
- 48.9 Checking ONOS nodes - PASS
- 48.10 Checking ONOS applications - PASS
- 48.11 Set logging levels - PASS
- 48.12 Set ONOS configurations - PASS
- 48.13 Starting Mininet Topology - PASS
- 48.14 Check whether the flow count is >= 212 - FAIL
- Flow count looks wrong; found 108, expecting at least 212
- 48.15 Check whether all flow status are ADDED - PASS
- 48.16 Check whether the flow count of device of:0000000000000001 >= than 53 - FAIL
- Flow count looks wrong: 18
- 48.17 Check whether the flow count of device of:0000000000000002 >= than 53 - FAIL
- Flow count looks wrong: 18
- 48.18 Check whether the flow count of device of:0000000000000003 >= than 53 - FAIL
- Flow count looks wrong: 18
- 48.19 Check whether the flow count of device of:0000000000000004 >= than 53 - FAIL
- Flow count looks wrong: 18
- 48.20 Check number of topology elements - FAIL
- Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
- ONOS sees 6 devices (6 expected) and 36 links (38 expected) and 3 controllers (3 expected) and 1 SCCs (1 expected)
- 48.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE48 - FAIL
- IP connectivity failed
- 48.22 Verify full connectivity for [u'h3', u'h4'] with tag CASE48 - FAIL
- IP connectivity failed
- 48.23 Stopping Mininet - PASS
- 48.24 Copying karaf logs - PASS
Case 55: Bridging test between two untagged hosts with different vlan id, with single ToR, ovs switches and 3 ONOS instances - PASS
- 55.1 Apply cell to environment - PASS
- 55.2 Uninstalling Atomix - PASS
- 55.3 Uninstalling ONOS package - PASS
- 55.4 Installing Atomix - PASS
- 55.5 Installing ONOS package - PASS
- 55.6 Set up ONOS secure SSH - PASS
- 55.7 Checking ONOS service - PASS
- 55.8 Starting ONOS CLI sessions - PASS
- 55.9 Checking ONOS nodes - PASS
- 55.10 Checking ONOS applications - PASS
- 55.11 Set logging levels - PASS
- 55.12 Set ONOS configurations - PASS
- 55.13 Starting Mininet Topology - PASS
- 55.14 Check whether the flow count is >= 28 - PASS
- 55.15 Check whether all flow status are ADDED - PASS
- 55.16 Check whether the flow count of device of:0000000000000001 >= than 28 - PASS
- 55.17 Check number of topology elements - PASS
- 55.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE55 - PASS
- 55.19 Stopping Mininet - PASS
- 55.20 Copying karaf logs - PASS
Case 56: Bridging test between two untagged hosts with different vlan id, with dual-homed ToR, ovs switches and 3 ONOS instances - PASS
- 56.1 Apply cell to environment - PASS
- 56.2 Uninstalling Atomix - PASS
- 56.3 Uninstalling ONOS package - PASS
- 56.4 Installing Atomix - PASS
- 56.5 Installing ONOS package - PASS
- 56.6 Set up ONOS secure SSH - PASS
- 56.7 Checking ONOS service - PASS
- 56.8 Starting ONOS CLI sessions - PASS
- 56.9 Checking ONOS nodes - PASS
- 56.10 Checking ONOS applications - PASS
- 56.11 Set logging levels - PASS
- 56.12 Set ONOS configurations - PASS
- 56.13 Starting Mininet Topology - PASS
- 56.14 Check whether the flow count is >= 74 - PASS
- 56.15 Check whether all flow status are ADDED - PASS
- 56.16 Check whether the flow count of device of:0000000000000001 >= than 37 - PASS
- 56.17 Check whether the flow count of device of:0000000000000002 >= than 37 - PASS
- 56.18 Check number of topology elements - PASS
- 56.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE56 - PASS
- 56.20 Stopping Mininet - PASS
- 56.21 Copying karaf logs - PASS
Case 57: Bridging test between two untagged hosts with different vlan id, with 2x2 leaf-spine topology, ovs switches and 3 ONOS instances - FAIL
...
Case 35: Bridging test between two untagged hosts, one on vlan-untagged port and the other on vlan-native port, with single ToR, ovs switches and 3 ONOS instances - FAIL
Case
...
35: Bridging test between two untagged hosts
...
, one on vlan-untagged port and the other on vlan-native port, with single ToR, ovs switches and 3 ONOS instances - FAIL
Case
...
35: Bridging test between two untagged hosts
...