Due to a ransomware attack, the wiki was reverted to a July 2022 version. . We apologize for the lack of a more recent valid backup.
...
HTML |
---|
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric2/lastSuccessfulBuild/artifact/SRBridging_onos-2.5_20-builds_graph.jpg", alt="SRBridging", style="width:525px;height:350px;border:0"> |
commit b784d9817744798adbeb97948c33bbd09e72e0ca b4120ff8d320e89a0eb9cc6b8c7580918e4d8f89 (HEAD -] onos-2.5, origin/onos-2.5)
Author: Daniele Moro pierventre [daniele@opennetworkingpier@opennetworking.org]
AuthorDate: Fri May 21 17:08:29 Apr 9 14:32:11 2021 +0200
Commit: Pier Luigi Ventre [pier@opennetworking.org]
CommitDate: Tue May 25 13:07:31 Thu Jun 3 07:33:22 2021 +0000
Fix onos-dependencies snapshots artifacts upload
--
(cherry picked from commit 385cdd7b6302a09fe09a6843127e6c60273123c4)
[SDFAB-16][SDFAB-17] Several improvements to the GDP
Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR, ovs switches and 3 ONOS instances - PASS
...
- 15.1 Apply cell to environment - PASS
- 15.2 Uninstalling Atomix - PASS
- 15.3 Uninstalling ONOS package - PASS
- 15.4 Installing Atomix - PASS
- 15.5 Installing ONOS package - PASS
- 15.6 Set up ONOS secure SSH - PASS
- 15.7 Checking ONOS service - PASS
- 15.8 Starting ONOS CLI sessions - PASS
- 15.9 Checking ONOS nodes - PASS
- 15.10 Checking ONOS applications - PASS
- 15.11 Set logging levels - PASS
- 15.12 Set ONOS configurations - PASS
- 15.13 Starting Mininet Topology - PASS
- 15.14 Check whether the flow count is bigger than 28 - PASS
- 15.15 Check whether all flow status are ADDED - PASS
- 15.16 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS
- 15.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE15 - PASS
- 15.18 Stopping Mininet - PASS
- 15.19 Copying karaf logs - PASS
Case 16: Bridging test between two tagged hosts, with dual-homed ToR, ovs switches and 3 ONOS instances -
...
FAIL
- 16.1 Apply cell to environment - PASS
- 16.2 Uninstalling Atomix - PASS
- 16.3 Uninstalling ONOS package - PASS
- 16.4 Installing Atomix - PASS
- 16.5 Installing ONOS package - PASS
- 16.6 Set up ONOS secure SSH - PASS
- 16.7 Checking ONOS service - PASS
- 16.8 Starting ONOS CLI sessions - PASS
- 16.9 Checking ONOS nodes - PASS
- 16.10 Checking ONOS applications - PASS
- 16.11 Set logging levels - PASS
- 16.12 Set ONOS configurations - PASS
- 16.13 Starting Mininet Topology - PASS
- 16.14 Check whether the flow count is bigger than 74 - PASS FAIL
- Flow count looks wrong; found 34, expecting at least 74
- 16.15 Check whether all flow status are ADDED - PASS
- 16.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 16.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 16.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE16 - PASS
- 16.19 Stopping Mininet - PASS
- 16.20 Copying karaf logs - PASS
...
- 25.1 Apply cell to environment - PASS
- 25.2 Uninstalling Atomix - PASS
- 25.3 Uninstalling ONOS package - PASS
- 25.4 Installing Atomix - PASS
- 25.5 Installing ONOS package - PASS
- 25.6 Set up ONOS secure SSH - PASS
- 25.7 Checking ONOS service - PASS
- 25.8 Starting ONOS CLI sessions - PASS
- 25.9 Checking ONOS nodes - PASS
- 25.10 Checking ONOS applications - PASS
- 25.11 Set logging levels - PASS
- 25.12 Set ONOS configurations - PASS
- 25.13 Starting Mininet Topology - PASS
- 25.14 Check whether the flow count is bigger than 28 - PASS
- 25.15 Check whether all flow status are ADDED - PASS
- 25.16 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS
- 25.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE25 - PASS
- 25.18 Stopping Mininet - PASS
- 25.19 Copying karaf logs - PASS
Case 26: Bridging test between two untagged hosts on vlan-native port, with dual-homed ToR, ovs switches and 3 ONOS instances -
...
PASS
- 26.1 Apply cell to environment - PASS
- 26.2 Uninstalling Atomix - PASS
- 26.3 Uninstalling ONOS package - PASS
- 26.4 Installing Atomix - PASS
- 26.5 Installing ONOS package - PASS
- 26.6 Set up ONOS secure SSH - PASS
- 26.7 Checking ONOS service - PASS
- 26.8 Starting ONOS CLI sessions - PASS
- 26.9 Checking ONOS nodes - PASS
- 26.10 Checking ONOS applications - PASS
- 26.11 Set logging levels - PASS
- 26.12 Set ONOS configurations - PASS
- 26.13 Starting Mininet Topology - PASS
- 26.14 Check whether the flow count is bigger than 74 - FAIL
- Flow count looks wrong; found 39, expecting at least 74
- PASS
- 26.15 Check whether all flow status are ADDED - PASS
- 26.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 26.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 26.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE26 - PASS
- 26.19 Stopping Mininet - PASS
- 26.20 Copying karaf logs - PASS
...
- 46.1 Apply cell to environment - PASS
- 46.2 Uninstalling Atomix - PASS
- 46.3 Uninstalling ONOS package - PASS
- 46.4 Installing Atomix - PASS
- 46.5 Installing ONOS package - PASS
- 46.6 Set up ONOS secure SSH - PASS
- 46.7 Checking ONOS service - PASS
- 46.8 Starting ONOS CLI sessions - PASS
- 46.9 Checking ONOS nodes - PASS
- 46.10 Checking ONOS applications - PASS
- 46.11 Set logging levels - PASS
- 46.12 Set ONOS configurations - PASS
- 46.13 Starting Mininet Topology - PASS
- 46.14 Check whether the flow count is bigger than 74 - PASS
- 46.15 Check whether all flow status are ADDED - PASS
- 46.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 46.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 46.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE46 - PASS
- 46.19 Stopping Mininet - PASS
- 46.20 Copying karaf logs - PASS
Case 47: Bridging test between untagged host and tagged host, with 2x2 leaf-spine topology, ovs switches and 3 ONOS instances -
...
FAIL
- 47.1 Apply cell to environment - PASS
- 47.2 Uninstalling Atomix - PASS
- 47.3 Uninstalling ONOS package - PASS
- 47.4 Installing Atomix - PASS
- 47.5 Installing ONOS package - PASS
- 47.6 Set up ONOS secure SSH - PASS
- 47.7 Checking ONOS service - PASS
- 47.8 Starting ONOS CLI sessions - PASS
- 47.9 Checking ONOS nodes - PASS
- 47.10 Checking ONOS applications - PASS
- 47.11 Set logging levels - PASS
- 47.12 Set ONOS configurations - PASS
- 47.13 Starting Mininet Topology - PASS
- 47.14 Check whether the flow count is bigger than 74 - PASS
- 47.15 Check whether all flow status are ADDED - PASS
- 47.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS FAIL
- Flow count looks wrong: 18
- 47.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 47.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE47 - PASS
- 47.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE47 - PASS FAIL
- IP connectivity failed
- 47.20 Stopping Mininet - PASS
- 47.21 Copying karaf logs - PASS
...
- 65.1 Apply cell to environment - PASS
- 65.2 Uninstalling Atomix - PASS
- 65.3 Uninstalling ONOS package - PASS
- 65.4 Installing Atomix - PASS
- 65.5 Installing ONOS package - PASS
- 65.6 Set up ONOS secure SSH - PASS
- 65.7 Checking ONOS service - PASS
- 65.8 Starting ONOS CLI sessions - PASS
- 65.9 Checking ONOS nodes - PASS
- 65.10 Checking ONOS applications - PASS
- 65.11 Set logging levels - PASS
- 65.12 Set ONOS configurations - PASS
- 65.13 Starting Mininet Topology - PASS
- 65.14 Check whether the flow count is bigger than 28 - PASS
- 65.15 Check whether all flow status are ADDED - PASS
- 65.16 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS
- 65.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE65 - PASS
- 65.18 Stopping Mininet - PASS
- 65.19 Copying karaf logs - PASS
Case 66: Bridging test between two tagged hosts with different vlan id, with dual-homed ToR, ovs switches and 3 ONOS instances -
...
FAIL
- 66.1 Apply cell to environment - PASS
- 66.2 Uninstalling Atomix - PASS
- 66.3 Uninstalling ONOS package - PASS
- 66.4 Installing Atomix - PASS
- 66.5 Installing ONOS package - PASS
- 66.6 Set up ONOS secure SSH - PASS
- 66.7 Checking ONOS service - PASS
- 66.8 Starting ONOS CLI sessions - PASS
- 66.9 Checking ONOS nodes - PASS
- 66.10 Checking ONOS applications - PASS
- 66.11 Set logging levels - PASS
- 66.12 Set ONOS configurations - PASS
- 66.13 Starting Mininet Topology - PASS
- 66.14 Check whether the flow count is bigger than 74 - PASS FAIL
- Flow count looks wrong; found 34, expecting at least 74
- 66.15 Check whether all flow status are ADDED - PASS
- 66.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 66.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 66.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE66 - PASS
- 66.19 Stopping Mininet - PASS
- 66.20 Copying karaf logs - PASS
...
- 67.1 Apply cell to environment - PASS
- 67.2 Uninstalling Atomix - PASS
- 67.3 Uninstalling ONOS package - PASS
- 67.4 Installing Atomix - PASS
- 67.5 Installing ONOS package - PASS
- 67.6 Set up ONOS secure SSH - PASS
- 67.7 Checking ONOS service - PASS
- 67.8 Starting ONOS CLI sessions - PASS
- 67.9 Checking ONOS nodes - PASS
- 67.10 Checking ONOS applications - PASS
- 67.11 Set logging levels - PASS
- 67.12 Set ONOS configurations - PASS
- 67.13 Starting Mininet Topology - PASS
- 67.14 Check whether the flow count is bigger than 74 - PASS
- 67.15 Check whether all flow status are ADDED - PASS
- 67.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 67.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 67.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE67 - PASS
- 67.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE67 - PASS
- 67.20 Stopping Mininet - PASS
- 67.21 Copying karaf logs - PASS
Case 68: Bridging test between two tagged hosts with different vlan id, with 2x4 dual-homed leaf-spine topology, ovs switches and 3 ONOS instances -
...
PASS
- 68.1 Apply cell to environment - PASS
- 68.2 Uninstalling Atomix - PASS
- 68.3 Uninstalling ONOS package - PASS
- 68.4 Installing Atomix - PASS
- 68.5 Installing ONOS package - PASS
- 68.6 Set up ONOS secure SSH - PASS
- 68.7 Checking ONOS service - PASS
- 68.8 Starting ONOS CLI sessions - PASS
- 68.9 Checking ONOS nodes - PASS
- 68.10 Checking ONOS applications - PASS
- 68.11 Set logging levels - PASS
- 68.12 Set ONOS configurations - PASS
- 68.13 Starting Mininet Topology - PASS
- 68.14 Check whether the flow count is bigger than 212 - PASS
- 68.15 Check whether all flow status are ADDED - PASS
- 68.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 68.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - FAIL
- Flow count looks wrong: 23
- PASS
- 68.18 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS
- 68.19 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS
- 68.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE68 - PASS
- 68.21 Verify full connectivity for [u'h3', u'h4'] with tag CASE68 - PASS
- 68.22 Stopping Mininet - PASS
- 68.23 Copying karaf logs - PASS
...
- 77.1 Apply cell to environment - PASS
- 77.2 Uninstalling Atomix - PASS
- 77.3 Uninstalling ONOS package - PASS
- 77.4 Installing Atomix - PASS
- 77.5 Installing ONOS package - PASS
- 77.6 Set up ONOS secure SSH - PASS
- 77.7 Checking ONOS service - PASS
- 77.8 Starting ONOS CLI sessions - PASS
- 77.9 Checking ONOS nodes - PASS
- 77.10 Checking ONOS applications - PASS
- 77.11 Set logging levels - PASS
- 77.12 Set ONOS configurations - PASS
- 77.13 Starting Mininet Topology - PASS
- 77.14 Check whether the flow count is bigger than 74 - PASS
- 77.15 Check whether all flow status are ADDED - PASS
- 77.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 77.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 77.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE77 - PASS
- 77.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE77 - PASS
- 77.20 Stopping Mininet - PASS
- 77.21 Copying karaf logs - PASS
Case 78: Bridging test between untagged and tagged hosts with different vlan id, with 2x4 dual-homed leaf-spine topology, ovs switches and 3 ONOS instances -
...
FAIL
- 78.1 Apply cell to environment - PASS
- 78.2 Uninstalling Atomix - PASS
- 78.3 Uninstalling ONOS package - PASS
- 78.4 Installing Atomix - PASS
- 78.5 Installing ONOS package - PASS
- 78.6 Set up ONOS secure SSH - PASS
- 78.7 Checking ONOS service - PASS
- 78.8 Starting ONOS CLI sessions - PASS
- 78.9 Checking ONOS nodes - PASS
- 78.10 Checking ONOS applications - PASS
- 78.11 Set logging levels - PASS
- 78.12 Set ONOS configurations - PASS
- 78.13 Starting Mininet Topology - PASS
- 78.14 Check whether the flow count is bigger than 212 - PASS
- 78.15 Check whether all flow status are ADDED - PASS FAIL
- Flow status is wrong!
- 78.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 78.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 78.18 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS
- 78.19 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS
- 78.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE78 - PASS
- 78.21 Verify full connectivity for [u'h3', u'h4'] with tag CASE78 - PASS
- 78.22 Stopping Mininet - PASS
- 78.23 Copying karaf logs - PASS