Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

HTML
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric2/lastSuccessfulBuild/artifact/SRBridging_onos-2.5_20-builds_graph.jpg", alt="SRBridging", style="width:525px;height:350px;border:0">

commit b784d9817744798adbeb97948c33bbd09e72e0ca b4120ff8d320e89a0eb9cc6b8c7580918e4d8f89 (HEAD -] onos-2.5, origin/onos-2.5)
Author: Daniele Moro pierventre [daniele@opennetworkingpier@opennetworking.org]
AuthorDate: Fri May 21 17:08:29 Apr 9 14:32:11 2021 +0200
Commit: Pier Luigi Ventre [pier@opennetworking.org]
CommitDate: Tue May 25 13:07:31 Thu Jun 3 07:33:22 2021 +0000
Fix onos-dependencies snapshots artifacts upload
--
(cherry picked from commit 385cdd7b6302a09fe09a6843127e6c60273123c4)
[SDFAB-16][SDFAB-17] Several improvements to the GDP

Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR, ovs switches and 3 ONOS instances - PASS

...

  • 15.1 Apply cell to environment - PASS (tick)
  • 15.2 Uninstalling Atomix - PASS (tick)
  • 15.3 Uninstalling ONOS package - PASS (tick)
  • 15.4 Installing Atomix - PASS (tick)
  • 15.5 Installing ONOS package - PASS (tick)
  • 15.6 Set up ONOS secure SSH - PASS (tick)
  • 15.7 Checking ONOS service - PASS (tick)
  • 15.8 Starting ONOS CLI sessions - PASS (tick)
  • 15.9 Checking ONOS nodes - PASS (tick)
  • 15.10 Checking ONOS applications - PASS (tick)
  • 15.11 Set logging levels - PASS (tick)
  • 15.12 Set ONOS configurations - PASS (tick)
  • 15.13 Starting Mininet Topology - PASS (tick)
  • 15.14 Check whether the flow count is bigger than 28 - PASS (tick)
  • 15.15 Check whether all flow status are ADDED - PASS (tick)
  • 15.16 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS (tick)
  • 15.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE15 - PASS (tick)
  • 15.18 Stopping Mininet - PASS (tick)
  • 15.19 Copying karaf logs - PASS (tick)

Case 16: Bridging test between two tagged hosts, with dual-homed ToR, ovs switches and 3 ONOS instances -

...

FAIL

  • 16.1 Apply cell to environment - PASS (tick)
  • 16.2 Uninstalling Atomix - PASS (tick)
  • 16.3 Uninstalling ONOS package - PASS (tick)
  • 16.4 Installing Atomix - PASS (tick)
  • 16.5 Installing ONOS package - PASS (tick)
  • 16.6 Set up ONOS secure SSH - PASS (tick)
  • 16.7 Checking ONOS service - PASS (tick)
  • 16.8 Starting ONOS CLI sessions - PASS (tick)
  • 16.9 Checking ONOS nodes - PASS (tick)
  • 16.10 Checking ONOS applications - PASS (tick)
  • 16.11 Set logging levels - PASS (tick)
  • 16.12 Set ONOS configurations - PASS (tick)
  • 16.13 Starting Mininet Topology - PASS (tick)
  • 16.14 Check whether the flow count is bigger than 74 - PASS (tick)FAIL (error)
    • Flow count looks wrong; found 34, expecting at least 74
  • 16.15 Check whether all flow status are ADDED - PASS (tick)
  • 16.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 16.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 16.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE16 - PASS (tick)
  • 16.19 Stopping Mininet - PASS (tick)
  • 16.20 Copying karaf logs - PASS (tick)

...

  • 25.1 Apply cell to environment - PASS (tick)
  • 25.2 Uninstalling Atomix - PASS (tick)
  • 25.3 Uninstalling ONOS package - PASS (tick)
  • 25.4 Installing Atomix - PASS (tick)
  • 25.5 Installing ONOS package - PASS (tick)
  • 25.6 Set up ONOS secure SSH - PASS (tick)
  • 25.7 Checking ONOS service - PASS (tick)
  • 25.8 Starting ONOS CLI sessions - PASS (tick)
  • 25.9 Checking ONOS nodes - PASS (tick)
  • 25.10 Checking ONOS applications - PASS (tick)
  • 25.11 Set logging levels - PASS (tick)
  • 25.12 Set ONOS configurations - PASS (tick)
  • 25.13 Starting Mininet Topology - PASS (tick)
  • 25.14 Check whether the flow count is bigger than 28 - PASS (tick)
  • 25.15 Check whether all flow status are ADDED - PASS (tick)
  • 25.16 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS (tick)
  • 25.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE25 - PASS (tick)
  • 25.18 Stopping Mininet - PASS (tick)
  • 25.19 Copying karaf logs - PASS (tick)

Case 26: Bridging test between two untagged hosts on vlan-native port, with dual-homed ToR, ovs switches and 3 ONOS instances -

...

PASS

  • 26.1 Apply cell to environment - PASS (tick)
  • 26.2 Uninstalling Atomix - PASS (tick)
  • 26.3 Uninstalling ONOS package - PASS (tick)
  • 26.4 Installing Atomix - PASS (tick)
  • 26.5 Installing ONOS package - PASS (tick)
  • 26.6 Set up ONOS secure SSH - PASS (tick)
  • 26.7 Checking ONOS service - PASS (tick)
  • 26.8 Starting ONOS CLI sessions - PASS (tick)
  • 26.9 Checking ONOS nodes - PASS (tick)
  • 26.10 Checking ONOS applications - PASS (tick)
  • 26.11 Set logging levels - PASS (tick)
  • 26.12 Set ONOS configurations - PASS (tick)
  • 26.13 Starting Mininet Topology - PASS (tick)
  • 26.14 Check whether the flow count is bigger than 74 - FAIL (error)
    • Flow count looks wrong; found 39, expecting at least 74
  • PASS (tick)
  • 26.15 Check whether all flow status are ADDED - PASS (tick)
  • 26.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 26.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 26.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE26 - PASS (tick)
  • 26.19 Stopping Mininet - PASS (tick)
  • 26.20 Copying karaf logs - PASS (tick)

...

  • 46.1 Apply cell to environment - PASS (tick)
  • 46.2 Uninstalling Atomix - PASS (tick)
  • 46.3 Uninstalling ONOS package - PASS (tick)
  • 46.4 Installing Atomix - PASS (tick)
  • 46.5 Installing ONOS package - PASS (tick)
  • 46.6 Set up ONOS secure SSH - PASS (tick)
  • 46.7 Checking ONOS service - PASS (tick)
  • 46.8 Starting ONOS CLI sessions - PASS (tick)
  • 46.9 Checking ONOS nodes - PASS (tick)
  • 46.10 Checking ONOS applications - PASS (tick)
  • 46.11 Set logging levels - PASS (tick)
  • 46.12 Set ONOS configurations - PASS (tick)
  • 46.13 Starting Mininet Topology - PASS (tick)
  • 46.14 Check whether the flow count is bigger than 74 - PASS (tick)
  • 46.15 Check whether all flow status are ADDED - PASS (tick)
  • 46.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 46.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 46.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE46 - PASS (tick)
  • 46.19 Stopping Mininet - PASS (tick)
  • 46.20 Copying karaf logs - PASS (tick)

Case 47: Bridging test between untagged host and tagged host, with 2x2 leaf-spine topology, ovs switches and 3 ONOS instances -

...

FAIL

  • 47.1 Apply cell to environment - PASS (tick)
  • 47.2 Uninstalling Atomix - PASS (tick)
  • 47.3 Uninstalling ONOS package - PASS (tick)
  • 47.4 Installing Atomix - PASS (tick)
  • 47.5 Installing ONOS package - PASS (tick)
  • 47.6 Set up ONOS secure SSH - PASS (tick)
  • 47.7 Checking ONOS service - PASS (tick)
  • 47.8 Starting ONOS CLI sessions - PASS (tick)
  • 47.9 Checking ONOS nodes - PASS (tick)
  • 47.10 Checking ONOS applications - PASS (tick)
  • 47.11 Set logging levels - PASS (tick)
  • 47.12 Set ONOS configurations - PASS (tick)
  • 47.13 Starting Mininet Topology - PASS (tick)
  • 47.14 Check whether the flow count is bigger than 74 - PASS (tick)
  • 47.15 Check whether all flow status are ADDED - PASS (tick)
  • 47.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)FAIL (error)
    • Flow count looks wrong: 18
  • 47.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 47.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE47 - PASS (tick)
  • 47.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE47 - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 47.20 Stopping Mininet - PASS (tick)
  • 47.21 Copying karaf logs - PASS (tick)

...

  • 65.1 Apply cell to environment - PASS (tick)
  • 65.2 Uninstalling Atomix - PASS (tick)
  • 65.3 Uninstalling ONOS package - PASS (tick)
  • 65.4 Installing Atomix - PASS (tick)
  • 65.5 Installing ONOS package - PASS (tick)
  • 65.6 Set up ONOS secure SSH - PASS (tick)
  • 65.7 Checking ONOS service - PASS (tick)
  • 65.8 Starting ONOS CLI sessions - PASS (tick)
  • 65.9 Checking ONOS nodes - PASS (tick)
  • 65.10 Checking ONOS applications - PASS (tick)
  • 65.11 Set logging levels - PASS (tick)
  • 65.12 Set ONOS configurations - PASS (tick)
  • 65.13 Starting Mininet Topology - PASS (tick)
  • 65.14 Check whether the flow count is bigger than 28 - PASS (tick)
  • 65.15 Check whether all flow status are ADDED - PASS (tick)
  • 65.16 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS (tick)
  • 65.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE65 - PASS (tick)
  • 65.18 Stopping Mininet - PASS (tick)
  • 65.19 Copying karaf logs - PASS (tick)

Case 66: Bridging test between two tagged hosts with different vlan id, with dual-homed ToR, ovs switches and 3 ONOS instances -

...

FAIL

  • 66.1 Apply cell to environment - PASS (tick)
  • 66.2 Uninstalling Atomix - PASS (tick)
  • 66.3 Uninstalling ONOS package - PASS (tick)
  • 66.4 Installing Atomix - PASS (tick)
  • 66.5 Installing ONOS package - PASS (tick)
  • 66.6 Set up ONOS secure SSH - PASS (tick)
  • 66.7 Checking ONOS service - PASS (tick)
  • 66.8 Starting ONOS CLI sessions - PASS (tick)
  • 66.9 Checking ONOS nodes - PASS (tick)
  • 66.10 Checking ONOS applications - PASS (tick)
  • 66.11 Set logging levels - PASS (tick)
  • 66.12 Set ONOS configurations - PASS (tick)
  • 66.13 Starting Mininet Topology - PASS (tick)
  • 66.14 Check whether the flow count is bigger than 74 - PASS (tick)FAIL (error)
    • Flow count looks wrong; found 34, expecting at least 74
  • 66.15 Check whether all flow status are ADDED - PASS (tick)
  • 66.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 66.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 66.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE66 - PASS (tick)
  • 66.19 Stopping Mininet - PASS (tick)
  • 66.20 Copying karaf logs - PASS (tick)

...

  • 67.1 Apply cell to environment - PASS (tick)
  • 67.2 Uninstalling Atomix - PASS (tick)
  • 67.3 Uninstalling ONOS package - PASS (tick)
  • 67.4 Installing Atomix - PASS (tick)
  • 67.5 Installing ONOS package - PASS (tick)
  • 67.6 Set up ONOS secure SSH - PASS (tick)
  • 67.7 Checking ONOS service - PASS (tick)
  • 67.8 Starting ONOS CLI sessions - PASS (tick)
  • 67.9 Checking ONOS nodes - PASS (tick)
  • 67.10 Checking ONOS applications - PASS (tick)
  • 67.11 Set logging levels - PASS (tick)
  • 67.12 Set ONOS configurations - PASS (tick)
  • 67.13 Starting Mininet Topology - PASS (tick)
  • 67.14 Check whether the flow count is bigger than 74 - PASS (tick)
  • 67.15 Check whether all flow status are ADDED - PASS (tick)
  • 67.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 67.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 67.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE67 - PASS (tick)
  • 67.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE67 - PASS (tick)
  • 67.20 Stopping Mininet - PASS (tick)
  • 67.21 Copying karaf logs - PASS (tick)

Case 68: Bridging test between two tagged hosts with different vlan id, with 2x4 dual-homed leaf-spine topology, ovs switches and 3 ONOS instances -

...

PASS

  • 68.1 Apply cell to environment - PASS (tick)
  • 68.2 Uninstalling Atomix - PASS (tick)
  • 68.3 Uninstalling ONOS package - PASS (tick)
  • 68.4 Installing Atomix - PASS (tick)
  • 68.5 Installing ONOS package - PASS (tick)
  • 68.6 Set up ONOS secure SSH - PASS (tick)
  • 68.7 Checking ONOS service - PASS (tick)
  • 68.8 Starting ONOS CLI sessions - PASS (tick)
  • 68.9 Checking ONOS nodes - PASS (tick)
  • 68.10 Checking ONOS applications - PASS (tick)
  • 68.11 Set logging levels - PASS (tick)
  • 68.12 Set ONOS configurations - PASS (tick)
  • 68.13 Starting Mininet Topology - PASS (tick)
  • 68.14 Check whether the flow count is bigger than 212 - PASS (tick)
  • 68.15 Check whether all flow status are ADDED - PASS (tick)
  • 68.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 68.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - FAIL (error)
    • Flow count looks wrong: 23
  • PASS (tick)
  • 68.18 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS (tick)
  • 68.19 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS (tick)
  • 68.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE68 - PASS (tick)
  • 68.21 Verify full connectivity for [u'h3', u'h4'] with tag CASE68 - PASS (tick)
  • 68.22 Stopping Mininet - PASS (tick)
  • 68.23 Copying karaf logs - PASS (tick)

...

  • 77.1 Apply cell to environment - PASS (tick)
  • 77.2 Uninstalling Atomix - PASS (tick)
  • 77.3 Uninstalling ONOS package - PASS (tick)
  • 77.4 Installing Atomix - PASS (tick)
  • 77.5 Installing ONOS package - PASS (tick)
  • 77.6 Set up ONOS secure SSH - PASS (tick)
  • 77.7 Checking ONOS service - PASS (tick)
  • 77.8 Starting ONOS CLI sessions - PASS (tick)
  • 77.9 Checking ONOS nodes - PASS (tick)
  • 77.10 Checking ONOS applications - PASS (tick)
  • 77.11 Set logging levels - PASS (tick)
  • 77.12 Set ONOS configurations - PASS (tick)
  • 77.13 Starting Mininet Topology - PASS (tick)
  • 77.14 Check whether the flow count is bigger than 74 - PASS (tick)
  • 77.15 Check whether all flow status are ADDED - PASS (tick)
  • 77.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 77.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 77.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE77 - PASS (tick)
  • 77.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE77 - PASS (tick)
  • 77.20 Stopping Mininet - PASS (tick)
  • 77.21 Copying karaf logs - PASS (tick)

Case 78: Bridging test between untagged and tagged hosts with different vlan id, with 2x4 dual-homed leaf-spine topology, ovs switches and 3 ONOS instances -

...

FAIL

  • 78.1 Apply cell to environment - PASS (tick)
  • 78.2 Uninstalling Atomix - PASS (tick)
  • 78.3 Uninstalling ONOS package - PASS (tick)
  • 78.4 Installing Atomix - PASS (tick)
  • 78.5 Installing ONOS package - PASS (tick)
  • 78.6 Set up ONOS secure SSH - PASS (tick)
  • 78.7 Checking ONOS service - PASS (tick)
  • 78.8 Starting ONOS CLI sessions - PASS (tick)
  • 78.9 Checking ONOS nodes - PASS (tick)
  • 78.10 Checking ONOS applications - PASS (tick)
  • 78.11 Set logging levels - PASS (tick)
  • 78.12 Set ONOS configurations - PASS (tick)
  • 78.13 Starting Mininet Topology - PASS (tick)
  • 78.14 Check whether the flow count is bigger than 212 - PASS (tick)
  • 78.15 Check whether all flow status are ADDED - PASS (tick)FAIL (error)
    • Flow status is wrong!
  • 78.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 78.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 78.18 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS (tick)
  • 78.19 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS (tick)
  • 78.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE78 - PASS (tick)
  • 78.21 Verify full connectivity for [u'h3', u'h4'] with tag CASE78 - PASS (tick)
  • 78.22 Stopping Mininet - PASS (tick)
  • 78.23 Copying karaf logs - PASS (tick)