Due to a ransomware attack, the wiki was reverted to a July 2022 version. . We apologize for the lack of a more recent valid backup.
...
- 6.1 Apply cell to environment - PASS
- 6.2 Uninstalling Atomix - PASS
- 6.3 Uninstalling ONOS package - PASS
- 6.4 Installing Atomix - PASS
- 6.5 Installing ONOS package - PASS
- 6.6 Set up ONOS secure SSH - PASS
- 6.7 Checking ONOS service - PASS
- 6.8 Starting ONOS CLI sessions - PASS
- 6.9 Checking ONOS nodes - PASS
- 6.10 Checking ONOS applications - PASS
- 6.11 Set logging levels - PASS
- 6.12 Set ONOS configurations - PASS
- 6.13 Starting Mininet Topology - PASS
- 6.14 Check whether the flow count is >= 74 - PASS
- 6.15 Check whether all flow status are ADDED - PASS
- 6.16 Check whether the flow count of device of:0000000000000001 >= than 37 - PASS
- 6.17 Check whether the flow count of device of:0000000000000002 >= than 37 - PASS
- 6.18 Check number of topology elements - PASS
- 6.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE6 - PASS
- 6.20 Stopping Mininet - PASS
- 6.21 Copying karaf logs - PASS
Case 7: Bridging test between two untagged hosts on vlan-untagged port, with 2x2 leaf-spine topology, ovs switches and 3 ONOS instances -
...
FAIL
- 7.1 Apply cell to environment - PASS
- 7.2 Uninstalling Atomix - PASS
- 7.3 Uninstalling ONOS package - PASS
- 7.4 Installing Atomix - PASS
- 7.5 Installing ONOS package - PASS
- 7.6 Set up ONOS secure SSH - PASS
- 7.7 Checking ONOS service - PASS
- 7.8 Starting ONOS CLI sessions - PASS
- 7.9 Checking ONOS nodes - PASS
- 7.10 Checking ONOS applications - PASS
- 7.11 Set logging levels - PASS
- 7.12 Set ONOS configurations - PASS
- 7.13 Starting Mininet Topology - PASS
- 7.14 Check whether the flow count is >= 74 - PASS FAIL
- Flow count looks wrong; found 72, expecting at least 74
- 7.15 Check whether all flow status are ADDED - PASS
- 7.16 Check whether the flow count of device of:0000000000000001 >= than 37 - PASS FAIL
- Flow count looks wrong: 18
- 7.17 Check whether the flow count of device of:0000000000000002 >= than 37 - PASS FAIL
- Flow count looks wrong: 18
- 7.18 Check number of topology elements - PASS
- 7.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE7 - PASS FAIL
- IP connectivity failed
- 7.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE7 - PASS FAIL
- IP connectivity failed
- 7.21 Stopping Mininet - PASS
- 7.22 Copying karaf logs - PASS
...
- 8.1 Apply cell to environment - PASS
- 8.2 Uninstalling Atomix - PASS
- 8.3 Uninstalling ONOS package - PASS
- 8.4 Installing Atomix - PASS
- 8.5 Installing ONOS package - PASS
- 8.6 Set up ONOS secure SSH - PASS
- 8.7 Checking ONOS service - PASS
- 8.8 Starting ONOS CLI sessions - PASS
- 8.9 Checking ONOS nodes - PASS
- 8.10 Checking ONOS applications - PASS
- 8.11 Set logging levels - PASS
- 8.12 Set ONOS configurations - PASS
- 8.13 Starting Mininet Topology - PASS
- 8.14 Check whether the flow count is >= 212 - PASS FAIL
- Flow count looks wrong; found 102, expecting at least 212
- 8.15 Check whether all flow status are ADDED - PASS
- 8.16 Check whether the flow count of device of:0000000000000001 >= than 53 - PASS FAIL
- Flow count looks wrong: 17
- 8.17 Check whether the flow count of device of:0000000000000002 >= than 53 - PASS FAIL
- Flow count looks wrong: 17
- 8.18 Check whether the flow count of device of:0000000000000003 >= than 53 - PASS FAIL
- Flow count looks wrong: 17
- 8.19 Check whether the flow count of device of:0000000000000004 >= than 53 - PASS FAIL
- Flow count looks wrong: 17
- 8.20 Check number of topology elements - FAIL
- Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
- ONOS sees 6 devices (6 expected) and 36 links (38 expected) and 3 controllers (3 expected) and 1 SCCs (1 expected)
- 8.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE8 - PASS FAIL
- IP connectivity failed
- 8.22 Verify full connectivity for [u'h3', u'h4'] with tag CASE8 - PASS FAIL
- IP connectivity failed
- 8.23 Stopping Mininet - PASS
- 8.24 Copying karaf logs - PASS
...
- 16.1 Apply cell to environment - PASS
- 16.2 Uninstalling Atomix - PASS
- 16.3 Uninstalling ONOS package - PASS
- 16.4 Installing Atomix - PASS
- 16.5 Installing ONOS package - PASS
- 16.6 Set up ONOS secure SSH - PASS
- 16.7 Checking ONOS service - PASS
- 16.8 Starting ONOS CLI sessions - PASS
- 16.9 Checking ONOS nodes - PASS
- 16.10 Checking ONOS applications - PASS
- 16.11 Set logging levels - PASS
- 16.12 Set ONOS configurations - PASS
- 16.13 Starting Mininet Topology - PASS
- 16.14 Check whether the flow count is >= 74 - PASS
- 16.15 Check whether all flow status are ADDED - PASS
- 16.16 Check whether the flow count of device of:0000000000000001 >= than 37 - PASS
- 16.17 Check whether the flow count of device of:0000000000000002 >= than 37 - PASS
- 16.18 Check number of topology elements - PASS
- 16.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE16 - PASS
- 16.20 Stopping Mininet - PASS
- 16.21 Copying karaf logs - PASS
Case 17: Bridging test between two tagged hosts, with 2x2 leaf-spine topology, ovs switches and 3 ONOS instances -
...
FAIL
- 17.1 Apply cell to environment - PASS
- 17.2 Uninstalling Atomix - PASS
- 17.3 Uninstalling ONOS package - PASS
- 17.4 Installing Atomix - PASS
- 17.5 Installing ONOS package - PASS
- 17.6 Set up ONOS secure SSH - PASS
- 17.7 Checking ONOS service - PASS
- 17.8 Starting ONOS CLI sessions - PASS
- 17.9 Checking ONOS nodes - PASS
- 17.10 Checking ONOS applications - PASS
- 17.11 Set logging levels - PASS
- 17.12 Set ONOS configurations - PASS
- 17.13 Starting Mininet Topology - PASS
- 17.14 Check whether the flow count is >= 74 - PASS FAIL
- Flow count looks wrong; found 68, expecting at least 74
- 17.15 Check whether all flow status are ADDED - PASS
- 17.16 Check whether the flow count of device of:0000000000000001 >= than 37 - PASS FAIL
- Flow count looks wrong: 17
- 17.17 Check whether the flow count of device of:0000000000000002 >= than 37 - PASS FAIL
- Flow count looks wrong: 17
- 17.18 Check number of topology elements - PASS
- 17.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE17 - PASS FAIL
- IP connectivity failed
- 17.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE17 - PASS FAIL
- IP connectivity failed
- 17.21 Stopping Mininet - PASS
- 17.22 Copying karaf logs - PASS
...
- 18.1 Apply cell to environment - PASS
- 18.2 Uninstalling Atomix - PASS
- 18.3 Uninstalling ONOS package - PASS
- 18.4 Installing Atomix - PASS
- 18.5 Installing ONOS package - PASS
- 18.6 Set up ONOS secure SSH - PASS
- 18.7 Checking ONOS service - PASS
- 18.8 Starting ONOS CLI sessions - PASS
- 18.9 Checking ONOS nodes - PASS
- 18.10 Checking ONOS applications - PASS
- 18.11 Set logging levels - PASS
- 18.12 Set ONOS configurations - PASS
- 18.13 Starting Mininet Topology - PASS
- 18.14 Check whether the flow count is >= 212 - PASS FAIL
- Flow count looks wrong; found 102, expecting at least 212
- 18. 18.15 Check whether all flow status are ADDED - PASS
- 18.16 Check whether the flow count of device of:0000000000000001 >= than 53 - PASS FAIL
- Flow count looks wrong: 17
- 18.17 Check whether the flow count of device of:0000000000000002 >= than 53 - PASS FAIL
- Flow count looks wrong: 17
- 18.18 Check whether the flow count of device of:0000000000000003 >= than 53 - PASS FAIL
- Flow count looks wrong: 17
- 18.19 Check whether the flow count of device of:0000000000000004 >= than 53 - PASS FAIL
- Flow count looks wrong: 17
- 18.20 Check number of topology elements - FAIL
- Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
- ONOS sees 6 devices (6 expected) and 36 links (38 expected) and 3 controllers (3 expected) and 1 SCCs (1 expected)
- 18.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE18 - PASS FAIL
- IP connectivity failed
- 18.22 Verify full connectivity for [u'h3', u'h4'] with tag CASE18 - PASS FAIL
- IP connectivity failed
- 18.23 Stopping Mininet - PASS
- 18.24 Copying karaf logs - PASS
...
- 25.1 Apply cell to environment - PASS
- 25.2 Uninstalling Atomix - PASS
- 25.3 Uninstalling ONOS package - PASS
- 25.4 Installing Atomix - PASS
- 25.5 Installing ONOS package - PASS
- 25.6 Set up ONOS secure SSH - PASS
- 25.7 Checking ONOS service - PASS
- 25.8 Starting ONOS CLI sessions - PASS
- 25.9 Checking ONOS nodes - PASS
- 25.10 Checking ONOS applications - PASS
- 25.11 Set logging levels - PASS
- 25.12 Set ONOS configurations - PASS
- 25.13 Starting Mininet Topology - PASS
- 25.14 Check whether the flow count is >= 28 - PASS
- 25.15 Check whether all flow status are ADDED - PASS
- 25.16 Check whether the flow count of device of:0000000000000001 >= than 28 - PASS
- 25.17 Check number of topology elements - PASS
- 25.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE25 - PASS
- 25.19 Stopping Mininet - PASS
- 25.20 Copying karaf logs - PASS
Case 26: Bridging test between two untagged hosts on vlan-native port, with dual-homed ToR, ovs switches and 3 ONOS instances -
...
PASS
- 26.1 Apply cell to environment - PASS
- 26.2 Uninstalling Atomix - PASS
- 26.3 Uninstalling ONOS package - PASS
- 26.4 Installing Atomix - PASS
- 26.5 Installing ONOS package - PASS
- 26.6 Set up ONOS secure SSH - PASS
- 26.7 Checking ONOS service - PASS
- 26.8 Starting ONOS CLI sessions - PASS
- 26.9 Checking ONOS nodes - PASS
- 26.10 Checking ONOS applications - PASS
- 26.11 Set logging levels - PASS
- 26.12 Set ONOS configurations - PASS
- 26.13 Starting Mininet Topology - PASS
- 26.14 Check whether the flow count is >= 74 - FAIL
- Flow count looks wrong; found 36, expecting at least 74
- PASS
- 26.15 Check whether all flow status are ADDED - PASS
- 26.16 Check whether the flow count of device of:0000000000000001 >= than 37 - FAIL Flow count looks wrong: 18
- PASS
- 26.17 Check whether the flow count of device of:0000000000000002 >= than 37 - FAIL
- Flow count looks wrong: 18
- PASS
- 26.18 Check number of topology elements - PASS
- 26.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE26 - FAIL IP connectivity failed
- PASS
- 26.20 Stopping Mininet - PASS
- 26.21 Copying karaf logs - PASS
Case 27: Bridging test between two untagged hosts on vlan-native port, with 2x2 leaf-spine topology, ovs switches and 3 ONOS instances -
...
PASS
- 27.1 Apply cell to environment - PASS
- 27.2 Uninstalling Atomix - PASS
- 27.3 Uninstalling ONOS package - PASS
- 27.4 Installing Atomix - PASS
- 27.5 Installing ONOS package - PASS
- 27.6 Set up ONOS secure SSH - PASS
- 27.7 Checking ONOS service - PASS
- 27.8 Starting ONOS CLI sessions - PASS
- 27.9 Checking ONOS nodes - PASS
- 27.10 Checking ONOS applications - PASS
- 27.11 Set logging levels - PASS
- 27.12 Set ONOS configurations - PASS
- 27.13 Starting Mininet Topology - PASS
- 27.14 Check whether the flow count is >= 74 - FAIL Flow count looks wrong; found 72, expecting at least 74
- PASS
- 27.15 Check whether all flow status are ADDED - PASS
- 27.16 Check whether the flow count of device of:0000000000000001 >= than 37 - FAIL Flow count looks wrong: 18
- :0000000000000001 >= than 37 - PASS
- 27.17 Check whether the flow count of device of:0000000000000002 >= than 37 - FAIL
- Flow count looks wrong: 18
- PASS
- 27.18 Check number of topology elements - PASS
- 27.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE27 - FAIL IP connectivity failed
- PASS
- 27.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE27 - FAIL
- IP connectivity failed
- PASS
- 27.21 Stopping Mininet - PASS
- 27.22 Copying karaf logs - PASS
...
- 35.1 Apply cell to environment - PASS
- 35.2 Uninstalling Atomix - PASS
- 35.3 Uninstalling ONOS package - PASS
- 35.4 Installing Atomix - PASS
- 35.5 Installing ONOS package - PASS
- 35.6 Set up ONOS secure SSH - PASS
- 35.7 Checking ONOS service - PASS
- 35.8 Starting ONOS CLI sessions - PASS
- 35.9 Checking ONOS nodes - PASS
- 35.10 Checking ONOS applications - PASS
- 35.11 Set logging levels - PASS
- 35.12 Set ONOS configurations - PASS
- 35.13 Starting Mininet Topology - PASS
- 35.14 Check whether the flow count is >= 28 - PASS
- 35.15 Check whether all flow status are ADDED - PASS
- 35.16 Check whether the flow count of device of:0000000000000001 >= than 28 - PASS
- 35.17 Check number of topology elements - PASS
- 35.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE35 - PASS
- 35.19 Stopping Mininet - PASS
- 35.20 Copying karaf logs - PASS
Case 36: Bridging test between two untagged hosts, one on vlan-untagged port and the other on vlan-native port, with dual-homed ToR, ovs switches and 3 ONOS instances -
...
FAIL
- 36.1 Apply cell to environment - PASS
- 36.2 Uninstalling Atomix - PASS
- 36.3 Uninstalling ONOS package - PASS
- 36.4 Installing Atomix - PASS
- 36.5 Installing ONOS package - PASS
- 36.6 Set up ONOS secure SSH - PASS
- 36.7 Checking ONOS service - PASS
- 36.8 Starting ONOS CLI sessions - PASS
- 36.9 Checking ONOS nodes - PASS
- 36.10 Checking ONOS applications - PASS
- 36.11 Set logging levels - PASS
- 36.12 Set ONOS configurations - PASS
- 36.13 Starting Mininet Topology - PASS
- 36.14 Check whether the flow count is >= 74 - PASS FAIL
- Flow count looks wrong; found 34, expecting at least 74
- 36.15 Check whether all flow status are ADDED - PASS
- 36.16 Check whether the flow count of device of:0000000000000001 >= than 37 - PASS FAIL
- Flow count looks wrong: 17
- 36.17 Check whether the flow count of device of:0000000000000002 >= than 37 - PASS FAIL
- Flow count looks wrong: 17
- 36.18 Check number of topology elements - PASS
- 36.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE36 - PASS FAIL
- IP connectivity failed
- 36.20 Stopping Mininet - PASS
- 36.21 Copying karaf logs - PASS
...
- 37.1 Apply cell to environment - PASS
- 37.2 Uninstalling Atomix - PASS
- 37.3 Uninstalling ONOS package - PASS
- 37.4 Installing Atomix - PASS
- 37.5 Installing ONOS package - PASS
- 37.6 Set up ONOS secure SSH - PASS
- 37.7 Checking ONOS service - PASS
- 37.8 Starting ONOS CLI sessions - PASS
- 37.9 Checking ONOS nodes - PASS
- 37.10 Checking ONOS applications - PASS
- 37.11 Set logging levels - PASS
- 37.12 Set ONOS configurations - PASS
- 37.13 Starting Mininet Topology - PASS
- 37.14 Check whether the flow count is >= 74 - PASS >= 74 - FAIL
- Flow count looks wrong; found 72, expecting at least 74
- 37.15 Check whether all flow status are ADDED - PASS
- 37.16 Check whether the flow count of device of:0000000000000001 >= than 37 - PASS FAIL
- Flow count looks wrong: 18
- 37.17 Check whether the flow count of device of:0000000000000002 >= than 37 - PASS FAIL
- Flow count looks wrong: 18
- 37.18 Check number of topology elements - PASS
- 37.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE37 - PASS FAIL
- IP connectivity failed
- 37.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE37 - FAIL
- IP connectivity failed
- 37.21 Stopping Mininet - PASS
- 37.22 Copying karaf logs - PASS
...
- 47.1 Apply cell to environment - PASS
- 47.2 Uninstalling Atomix - PASS
- 47.3 Uninstalling ONOS package - PASS
- 47.4 Installing Atomix - PASS
- 47.5 Installing ONOS package - PASS
- 47.6 Set up ONOS secure SSH - PASS
- 47.7 Checking ONOS service - PASS
- 47.8 Starting ONOS CLI sessions - PASS
- 47.9 Checking ONOS nodes - PASS
- 47.10 Checking ONOS applications - PASS
- 47.11 Set logging levels - PASS
- 47.12 Set ONOS configurations - PASS
- 47.13 Starting Mininet Topology - PASS
- 47.14 Check whether the flow count is >= 74 - PASS
- 47.15 Check whether all flow status are ADDED - PASS
- 47.16 Check whether the flow count of device of:0000000000000001 >= than 37 - PASS
- 47.17 Check whether the flow count of device of:0000000000000002 >= than 37 - PASS
- 47.18 Check number of topology elements - PASS
- 47.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE47 - FAIL
- IP connectivity failed
- PASS
- 47.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE47 - PASS FAIL
- IP connectivity failed
- 47.21 Stopping Mininet - PASS
- 47.22 Copying karaf logs - PASS
...
- 48.1 Apply cell to environment - PASS
- 48.2 Uninstalling Atomix - PASS
- 48.3 Uninstalling ONOS package - PASS
- 48.4 Installing Atomix - PASS
- 48.5 Installing ONOS package - PASS
- 48.6 Set up ONOS secure SSH - PASS
- 48.7 Checking ONOS service - PASS
- 48.8 Starting ONOS CLI sessions - PASS
- 48.9 Checking ONOS nodes - PASS
- 48.10 Checking ONOS applications - PASS
- 48.11 Set logging levels - PASS
- 48.12 Set ONOS configurations - PASS
- 48.13 Starting Mininet Topology - PASS
- 48.14 Check whether the flow count is >= 212 - PASS
- 48.15 Check whether all flow status are ADDED - PASS
- 48.16 Check whether the flow count of device of:0000000000000001 >= than 53 - PASS
- 48.17 Check whether the flow count of device of:0000000000000002 >= than 53 - PASS
- 48.18 Check whether the flow count of device of:0000000000000003 >= than 53 - PASS
- 48.19 Check whether the flow count of device of:0000000000000004 >= than 53 - PASS
- 48.20 Check number of topology elements - FAIL
- Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
- ONOS sees 6 devices (6 expected) and 36 links (38 expected) and 3 controllers (3 expected) and 1 SCCs (1 expected)
- 48.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE48 - PASS FAIL
- IP connectivity failed
- 48.22 Verify full connectivity for [u'h3', u'h4'] with tag CASE48 - PASS
- 48.23 Stopping Mininet - PASS
- 48.24 Copying karaf logs - PASS
...
- 55.1 Apply cell to environment - PASS
- 55.2 Uninstalling Atomix - PASS
- 55.3 Uninstalling ONOS package - PASS
- 55.4 Installing Atomix - PASS
- 55.5 Installing ONOS package - PASS
- 55.6 Set up ONOS secure SSH - PASS
- 55.7 Checking ONOS service - PASS
- 55.8 Starting ONOS CLI sessions - PASS
- 55.9 Checking ONOS nodes - PASS
- 55.10 Checking ONOS applications - PASS
- 55.11 Set logging levels - PASS
- 55.12 Set ONOS configurations - PASS
- 55.13 Starting Mininet Topology - PASS
- 55.14 Check whether the flow count is >= 28 - PASS
- 55.15 Check whether all flow status are ADDED - PASS
- 55.16 Check whether the flow count of device of:0000000000000001 >= than 28 - PASS
- 55.17 Check number of topology elements - PASS
- 55.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE55 - PASS
- 55.19 Stopping Mininet - PASS
- 55.20 Copying karaf logs - PASS
Case 56: Bridging test between two untagged hosts with different vlan id, with dual-homed ToR, ovs switches and 3 ONOS instances -
...
PASS
- 56.1 Apply cell to environment - PASS
- 56.2 Uninstalling Atomix - PASS
- 56.3 Uninstalling ONOS package - PASS
- 56.4 Installing Atomix - PASS
- 56.5 Installing ONOS package - PASS
- 56.6 Set up ONOS secure SSH - PASS
- 56.7 Checking ONOS service - PASS
- 56.8 Starting ONOS CLI sessions - PASS
- 56.9 Checking ONOS nodes - PASS
- 56.10 Checking ONOS applications - PASS
- 56.11 Set logging levels - PASS
- 56.12 Set ONOS configurations - PASS
- 56.13 Starting Mininet Topology - PASS
- 56.14 Check whether the flow count is >= 74 - FAIL
- Flow count looks wrong; found 34, expecting at least 74
- PASS
- 56.15 Check whether all flow status are ADDED - PASS
- 56.16 Check whether the flow count of device of:0000000000000001 >= than 37 - FAIL
- Flow count looks wrong: 17
- PASS
- 56.17 Check whether the flow count of device of:0000000000000002 >= than 37 - FAIL Flow count looks wrong: 17
- PASS
- 56.18 Check number of topology elements - PASS
- 56.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE56 - PASS
- 56.20 Stopping Mininet - PASS
- 56.21 Copying karaf logs - PASS
Case 57: Bridging test between two untagged hosts with different vlan id, with 2x2 leaf-spine topology, ovs switches and 3 ONOS instances -
...
PASS
- 57.1 Apply cell to environment - PASS
- 57.2 Uninstalling Atomix - PASS
- 57.3 Uninstalling ONOS package - PASS
- 57.4 Installing Atomix - PASS
- 57.5 Installing ONOS package - PASS
- 57.6 Set up ONOS secure SSH - PASS
- 57.7 Checking ONOS service - PASS
- 57.8 Starting ONOS CLI sessions - PASS
- 57.9 Checking ONOS nodes - PASS
- 57.10 Checking ONOS applications - PASS
- 57.11 Set logging levels - PASS
- 57.12 Set ONOS configurations - PASS
- 57.13 Starting Mininet Topology - PASS
- 57.14 Check whether the flow count is >= 74 - PASS
- 57.15 Check whether all flow status are ADDED - PASS
- 57.16 Check whether the flow count of device of:0000000000000001 >= than 37 - FAIL
- Flow count looks wrong: 19
- PASS
- 57.17 Check whether the flow count of device of:0000000000000002 >= than 37 - PASS
- 57.18 Check number of topology elements - PASS
- 57.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE57 - PASS
- 57.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE57 - PASS
- 57.21 Stopping Mininet - PASS
- 57.22 Copying karaf logs - PASS
...
- 58.1 Apply cell to environment - PASS
- 58.2 Uninstalling Atomix - PASS
- 58.3 Uninstalling ONOS package - PASS
- 58.4 Installing Atomix - PASS
- 58.5 Installing ONOS package - PASS
- 58.6 Set up ONOS secure SSH - PASS
- 58.7 Checking ONOS service - PASS
- 58.8 Starting ONOS CLI sessions - PASS
- 58.9 Checking ONOS nodes - PASS
- 58.10 Checking ONOS applications - PASS
- 58.11 Set logging levels - PASS
- 58.12 Set ONOS configurations - PASS
- 58.13 Starting Mininet Topology - PASS
- 58.14 Check whether the flow count is >= 212 - PASS FAIL
- Flow count looks wrong; found 108, expecting at least 212
- 58.15 Check whether all flow status are ADDED - PASS
- 58.16 Check whether the flow count of device of:0000000000000001 >= than 53 - FAIL
- Flow count looks wrong: 2018
- 58.17 Check whether the flow count of device of:0000000000000002 >= than 53 - PASS FAIL
- Flow count looks wrong: 18
- 58.18 Check whether the flow count of device of:0000000000000003 >= than 53 - FAIL
- Flow count looks wrong: 18
- 58.19 Check whether the flow count of device of:0000000000000004 >= than 53 - PASS FAIL
- Flow count looks wrong: 18
- 58.20 Check number of topology elements - FAIL
- Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
- ONOS sees 6 devices (6 expected) and 36 links (38 expected) and 3 controllers (3 expected) and 1 SCCs (1 expected)
- 58.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE58 - PASS
- 58.22 Verify full connectivity for [u'h3', u'h4'] with tag CASE58 - PASS
- 58.23 Stopping Mininet - PASS
- 58.24 Copying karaf logs - PASS
...
- 65.1 Apply cell to environment - PASS
- 65.2 Uninstalling Atomix - PASS
- 65.3 Uninstalling ONOS package - PASS
- 65.4 Installing Atomix - PASS
- 65.5 Installing ONOS package - PASS
- 65.6 Set up ONOS secure SSH - PASS
- 65.7 Checking ONOS service - PASS
- 65.8 Starting ONOS CLI sessions - PASS
- 65.9 Checking ONOS nodes - PASS
- 65.10 Checking ONOS applications - PASS
- 65.11 Set logging levels - PASS
- 65.12 Set ONOS configurations - PASS
- 65.13 Starting Mininet Topology - PASS
- 65.14 Check whether the flow count is >= 28 - PASS
- 65.15 Check whether all flow status are ADDED - PASS
- 65.16 Check whether the flow count of device of:0000000000000001 >= than 28 - PASS
- 65.17 Check number of topology elements - PASS
- 65.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE65 - PASS
- 65.19 Stopping Mininet - PASS
- 65.20 Copying karaf logs - PASS
Case 66: Bridging test between two tagged hosts with different vlan id, with dual-homed ToR, ovs switches and 3 ONOS instances -
...
PASS
- 66.1 Apply cell to environment - PASS
- 66.2 Uninstalling Atomix - PASS
- 66.3 Uninstalling ONOS package - PASS
- 66.4 Installing Atomix - PASS
- 66.5 Installing ONOS package - PASS
- 66.6 Set up ONOS secure SSH - PASS
- 66.7 Checking ONOS service - PASS
- 66.8 Starting ONOS CLI sessions - PASS
- 66.9 Checking ONOS nodes - PASS
- 66.10 Checking ONOS applications - PASS
- 66.11 Set logging levels - PASS
- 66.12 Set ONOS configurations - PASS
- 66.13 Starting Mininet Topology - PASS
- 66.14 Check whether the flow count is >= 74 - FAIL Flow count looks wrong; found 34, expecting at least 74
- PASS
- 66.15 Check whether all flow status are ADDED - PASS
- 66.16 Check whether the flow count of device of:0000000000000001 >= than 37 - FAIL
- Flow count looks wrong: 17
- PASS
- 66.17 Check whether the flow count of device of:0000000000000002 >= than 37 - FAIL
- Flow count looks wrong: 17
- PASS
- 66.18 Check number of topology elements - PASS
- 66.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE66 - PASS
- 66.20 Stopping Mininet - PASS
- 66.21 Copying karaf logs - PASS
...
- 68.1 Apply cell to environment - PASS
- 68.2 Uninstalling Atomix - PASS
- 68.3 Uninstalling ONOS package - PASS
- 68.4 Installing Atomix - PASS
- 68.5 Installing ONOS package - PASS
- 68.6 Set up ONOS secure SSH - PASS
- 68.7 Checking ONOS service - PASS
- 68.8 Starting ONOS CLI sessions - PASS
- 68.9 Checking ONOS nodes - PASS
- 68.10 Checking ONOS applications - PASS
- 68.11 Set logging levels - PASS
- 68.12 Set ONOS configurations - PASS
- 68.13 Starting Mininet Topology - PASS
- 68.14 Check whether the flow count is >= 212 - PASS
- 68.15 Check whether all flow status are ADDED - FAIL Flow status is wrong!
- PASS
- 68.16 Check whether the flow count of device of:0000000000000001 >= than 53 - PASS
- 68.17 Check whether the flow count of device of:0000000000000002 >= than 53 - PASS
- 68.18 Check whether the flow count of device of:0000000000000003 >= than 53 - PASS
- 68.19 Check whether the flow count of device of:0000000000000004 >= than 53 - PASS
- 68.20 Check number of topology elements - FAIL
- Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
- ONOS sees 6 devices (6 expected) and 36 links (38 expected) and 3 controllers (3 expected) and 1 SCCs (1 expected)
- 68.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE68 - PASS
- 68.22 Verify full connectivity for [u'h3', u'h4'] with tag CASE68 - PASS
- 68.23 Stopping Mininet - PASS
- 68.24 Copying karaf logs - PASS
...