Due to a ransomware attack, the wiki was reverted to a July 2022 version. . We apologize for the lack of a more recent valid backup.
...
| HTML |
|---|
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric4/lastSuccessfulBuild/artifact/SRDynamicConf_master_20-builds_graph.jpg", alt="SRDynamicConf", style="width:525px;height:350px;border:0"> |
commit d326de189984f69c97abb36be00f622683442137 48f1033bf1fb0b06c2e57962f6b110c231811533 (HEAD -] master, origin/master, origin/HEAD)
Author: Jordan Halterman [jordan@opennetworking.orgDaniel Park [dan.mcpark84@gmail.com]
AuthorDate: Tue Jul 31 11Thu Aug 2 10:57:21 27 2018 -0700+0900
Commit: Jordan Halterman Jian Li [jordan@opennetworkingpyguni@gmail.orgcom]
CommitDate: Wed Thu Aug 1 192 14:5200:05 17 2018 +0000
Allow Atomix nodes to be deployed on shared nodes for testing
Adds default router option only when the gateway is set in subnet.
Case 13: Changing port configuration from untagged 10 to tagged 10, with 2x2 leaf-spine topology and 3 ONOS instances - PASS
...
- 13.1 Constructing test variables - PASS
- 13.2 Apply cell to environment - PASS
- 13.3 Uninstalling Atomix - PASS
- 13.4 Uninstalling ONOS package - PASS
- 13.5 Creating ONOS package - PASS
- 13.6 Installing Atomix - PASS
- 13.7 Installing ONOS package - PASS
- 13.8 Set up ONOS secure SSH - PASS
- 13.9 Checking ONOS service - PASS
- 13.10 Starting ONOS CLI sessions - PASS
- 13.11 Starting Mininet Topology - PASS
- 13.12 Check whether the flow count is bigger than 104 - PASS
- 13.13 Check whether all flow status are ADDED - PASS
- 13.14 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE13_Before - PASS
- 13.15 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 13.16 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 13.17 Check whether the flow count is bigger than 104 - PASS
- 13.18 Check whether all flow status are ADDED - PASS
- 13.19 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE13_After - PASS
- 13.20 Stopping Mininet - PASS
- 13.21 Copying karaf logs - PASS
Case 23: Changing port configuration from untagged 10 to tagged 20 and native 10, with 2x2 leaf-spine topology and 3 ONOS instances -
...
PASS
- 23.1 Apply cell to environment - PASS
- 23.2 Uninstalling Atomix - PASS
- 23.3 Uninstalling ONOS package - PASS
- 23.4 Installing Atomix - PASS
- 23.5 Installing ONOS package - PASS
- 23.6 Set up ONOS secure SSH - PASS
- 23.7 Checking ONOS service - PASS
- 23.8 Starting ONOS CLI sessions - PASS
- 23.9 Starting Mininet Topology - PASS
- 23.10 Check whether the flow count is bigger than 106 - PASS
- 23.11 Check whether all flow status are ADDED - PASS
- 23.12 Verify full connectivity for [u'h3', u'h4'] with tag CASE23_Before - PASS
- 23.13 Verify full connectivity for [u'h1', u'h2'] with tag CASE23_Before - PASS
- 23.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 23.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 23.16 Check whether the flow count is bigger than 106 - PASS
- 23.17 Check whether all flow status are ADDED - FAIL
- Flow status is wrong!
- PASS
- 23.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE23_After - PASS
- 23.19 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE23_After - PASS
- 23.20 Stopping Mininet - PASS
- 23.21 Copying karaf logs - PASS
Case 33: Changing port configuration from untagged 10 to untagged 110, with 2x2 leaf-spine topology and 3 ONOS instances -
...
FAIL
- 33.1 Apply cell to environment - PASS
- 33.2 Uninstalling Atomix - PASS
- 33.3 Uninstalling ONOS package - PASS
- 33.4 Installing Atomix - PASS
- 33.5 Installing ONOS package - PASS
- 33.6 Set up ONOS secure SSH - PASS
- 33.7 Checking ONOS service - PASS
- 33.8 Starting ONOS CLI sessions - PASS
- 33.9 Starting Mininet Topology - PASS
- 33.10 Check whether the flow count is bigger than 104 - PASS
- 33.11 Check whether all flow status are ADDED - PASS
- 33.12 Verify full connectivity for [u'h3', u'h4'] with tag CASE33_Before - PASS
- 33.13 Verify full connectivity for [u'h1', u'h2'] with tag CASE33_Before - PASS
- 33.14 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 33.15 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 33.16 Check whether the flow count is bigger than 104 - PASS
- 33.17 Check whether all flow status are ADDED - PASS
FAIL
- Flow status is wrong!
- 33.18 Verify full connectivity for [u'h3', u'h4'] with tag CASE33_After - PASS
- 33.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE33_After - PASS
- 33.20 Stopping Mininet - PASS
- 33.21 Copying karaf logs - PASS
...
- 113.1 Apply cell to environment - PASS
- 113.2 Uninstalling Atomix - PASS
- 113.3 Uninstalling ONOS package - PASS
- 113.4 Installing Atomix - PASS
- 113.5 Installing ONOS package - PASS
- 113.6 Set up ONOS secure SSH - PASS
- 113.7 Checking ONOS service - PASS
- 113.8 Starting ONOS CLI sessions - PASS
- 113.9 Starting Mininet Topology - PASS
- 113.10 Check whether the flow count is bigger than 104 - PASS
- 113.11 Check whether all flow status are ADDED - PASS
- 113.12 Verify full connectivity for [u'h3', u'h4'] with tag CASE113_Before - PASS
- 113.13 Verify full connectivity for [u'h1', u'h2'] with tag CASE113_Before - PASS
- 113.14 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 113.15 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 113.16 Check whether the flow count is bigger than 104 - PASS
- 113.17 Check whether all flow status are ADDED - PASS
- 113.18 Verify full connectivity for [u'h3', u'h4'] with tag CASE113_After - PASS
- 113.19 Verify full connectivity for [u'h1', u'h2', u'h3'] with tag CASE113_After - PASS
- 113.20 Stopping Mininet - PASS
- 113.21 Copying karaf logs - PASS
Case 123: Changing port configuration from tagged 20 and native 10 to tagged 20 and native 110, with 2x2 leaf-spine topology and 3 ONOS instances -
...
PASS
- 123.1 Apply cell to environment - PASS
- 123.2 Uninstalling Atomix - PASS
- 123.3 Uninstalling ONOS package - PASS
- 123.4 Installing Atomix - PASS
- 123.5 Installing ONOS package - PASS
- 123.6 Set up ONOS secure SSH - PASS
- 123.7 Checking ONOS service - PASS
- 123.8 Starting ONOS CLI sessions - PASS
- 123.9 Starting Mininet Topology - PASS
- 123.10 Check whether the flow count is bigger than 104 - PASS
- 123.11 Check whether all flow status are ADDED - PASS
- 123.12 Verify full connectivity for [u'h3', u'h4'] with tag CASE123_Before - PASS
- 123.13 Verify full connectivity for [u'h1', u'h2'] with tag CASE123_Before - PASS
- 123.14 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 123.15 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 123.16 Check whether the flow count is bigger than 104 - PASS
- 123.17 Check whether all flow status are ADDED - FAIL
- Flow status is wrong!
- PASS
- 123.18 Verify full connectivity for [u'h3', u'h4'] with tag CASE123_After - PASS
- 123.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE123_After - PASS
- 123.20 Stopping Mininet - PASS
- 123.21 Copying karaf logs - PASS
...
- 133.1 Apply cell to environment - PASS
- 133.2 Uninstalling Atomix - PASS
- 133.3 Uninstalling ONOS package - PASS
- 133.4 Installing Atomix - PASS
- 133.5 Installing ONOS package - PASS
- 133.6 Set up ONOS secure SSH - PASS
- 133.7 Checking ONOS service - PASS
- 133.8 Starting ONOS CLI sessions - PASS
- 133.9 Starting Mininet Topology - PASS
- 133.10 Check whether the flow count is bigger than 104 - PASS
- 133.11 Check whether all flow status are ADDED - PASS
- 133.12 Verify full connectivity for [u'h3', u'h4'] with tag CASE133_Before - PASS
- 133.13 Verify full connectivity for [u'h1', u'h2'] with tag CASE133_Before - PASS
- 133.14 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 133.15 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 133.16 Check whether the flow count is bigger than 104 - PASS
- 133.17 Check whether all flow status are ADDED - PASS
- 133.18 Verify full connectivity for [u'h3', u'h4'] with tag CASE133_After - PASS
- 133.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE133_After - PASS
- 133.20 Stopping Mininet - PASS
- 133.21 Copying karaf logs - PASS
Case 143: Changing port configuration from untagged 10 to tagged 20, with 2x2 leaf-spine topology and 3 ONOS instances -
...
FAIL
- 143.1 Apply cell to environment - PASS
- 143.2 Uninstalling Atomix - PASS
- 143.3 Uninstalling ONOS package - PASS
- 143.4 Installing Atomix - PASS
- 143.5 Installing ONOS package - PASS
- 143.6 Set up ONOS secure SSH - PASS
- 143.7 Checking ONOS service - PASS
- 143.8 Starting ONOS CLI sessions - PASS
- 143.9 Starting Mininet Topology - PASS
- 143.10 Check whether the flow count is bigger than 106 - PASS
- 143.11 Check whether all flow status are ADDED - PASS
- 143.12 Verify full connectivity for [u'h3', u'h4'] with tag CASE143_Before - PASS
FAIL
- IP connectivity failed
- 143.13 Verify full connectivity for [u'h1', u'h2'] with tag CASE143_Before - PASS
- 143.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 143.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 143.16 Check whether the flow count is bigger than 106 - PASS
- 143.17 Check whether all flow status are ADDED - PASS
- 143.18 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE143_After - PASS
- 143.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE143_After - PASS
- 143.20 Stopping Mininet - PASS
- 143.21 Copying karaf logs - PASS
...
- 163.1 Apply cell to environment - PASS
- 163.2 Uninstalling Atomix - PASS
- 163.3 Uninstalling ONOS package - PASS
- 163.4 Installing Atomix - PASS
- 163.5 Installing ONOS package - PASS
- 163.6 Set up ONOS secure SSH - PASS
- 163.7 Checking ONOS service - PASS
- 163.8 Starting ONOS CLI sessions - PASS
- 163.9 Starting Mininet Topology - PASS
- 163.10 Check whether the flow count is bigger than 106 - PASS
- 163.11 Check whether all flow status are ADDED - PASS
- 163.12 Verify full connectivity for [u'h3', u'h4'] with tag CASE163_Before - PASS
- 163.13 Verify full connectivity for [u'h1', u'h2'] with tag CASE163_Before - PASS
- 163.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 163.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 163.16 Check whether the flow count is bigger than 106 - PASS
- 163.17 Check whether all flow status are ADDED - PASS
- 163.18 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE163_After - PASS
- 163.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE163_After - PASS
- 163.20 Stopping Mininet - PASS
- 163.21 Copying karaf logs - PASS
Case 173: Changing port configuration from tagged 20 to tagged 120, with 2x2 leaf-spine topology and 3 ONOS instances -
...
PASS
- 173.1 Apply cell to environment - PASS
- 173.2 Uninstalling Atomix - PASS
- 173.3 Uninstalling ONOS package - PASS
- 173.4 Installing Atomix - PASS
- 173.5 Installing ONOS package - PASS
- 173.6 Set up ONOS secure SSH - PASS
- 173.7 Checking ONOS service - PASS
- 173.8 Starting ONOS CLI sessions - PASS
- 173.9 Starting Mininet Topology - PASS
- 173.10 Check whether the flow count is bigger than 106 - PASS
- 173.11 Check whether all flow status are ADDED - PASS
- 173.12 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE173_Before - PASS
- 173.13 Verify full connectivity for [u'h1', u'h2'] with tag CASE173_Before - PASS
- 173.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 173.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 173.16 Check whether the flow count is bigger than 106 - PASS
- 173.17 Check whether all flow status are ADDED - FAIL
- PASS
- 173.18 Verify full connectivity for [u'h3', u'h4'] with tag CASE173_After - PASS
- 173.19 Verify full connectivity for [u'h1', u'h2', u'h3'] with tag CASE173_After - PASS
- 173.20 Stopping Mininet - PASS
- 173.21 Copying karaf logs - PASS
...