Due to a ransomware attack, the wiki was reverted to a July 2022 version. . We apologize for the lack of a more recent valid backup.
...
| HTML |
|---|
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric4/lastSuccessfulBuild/artifact/SRDynamicConf_master_20-builds_graph.jpg", alt="SRDynamicConf", style="width:525px;height:350px;border:0"> |
commit 245d119220fb86c1e1b7e51fbd78b1130f4de325 e3141545bae9480dc9f7a7158f8cc1d55912b121 (HEAD -] master, origin/master, origin/HEAD)
Author: Ray Milkey Jian Li [ray@opennetworkingpyguni@gmail.orgcom]
AuthorDate: Tue Mon Aug 14 1713 18:4905:33 43 2018 -0700+0900
Commit: Ray Milkey Jian Li [ray@opennetworkingpyguni@gmail.orgcom]
CommitDate: Tue Thu Aug 14 1716 01:4958:33 2018 -0700
No need to close the repo if doing a local deployment10 2018 +0000
Auto-generate an intg-bridge ID if it is not specified via net-cfg
Case 13: Changing port configuration from untagged 10 to tagged 10, with 2x2 leaf-spine topology and 3 ONOS instances - PASS
...
- 13.1 Constructing test variables - PASS
- 13.2 Apply cell to environment - PASS
- 13.3 Uninstalling Atomix - PASS
- 13.4 Uninstalling ONOS package - PASS
- 13.5 Creating ONOS package - PASS
- 13.6 Installing Atomix - PASS
- 13.7 Installing ONOS package - PASS
- 13.8 Set up ONOS secure SSH - PASS
- 13.9 Checking ONOS service - PASS
- 13.10 Starting ONOS CLI sessions - PASS
- 13.11 Checking ONOS nodes - PASS
- 13.12 Checking ONOS applications - PASS
- 13.13 Starting Mininet Topology - PASS
- 13.14 Check whether the flow count is bigger than 104 - PASS
- 13.15 Check whether all flow status are ADDED - PASS
- 13.16 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE13_Before - PASS
- 13.17 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 13.18 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 13.19 Check whether the flow count is bigger than 104 - PASS
- 13.20 Check whether all flow status are ADDED - PASS
- 13.21 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE13_After - PASS
- 13.22 Stopping Mininet - PASS
- 13.23 Copying karaf logs - PASS
Case 23: Changing port configuration from untagged 10 to tagged 20 and native 10, with 2x2 leaf-spine topology and 3 ONOS instances -
...
FAIL
- 23.1 Apply cell to environment - PASS
- 23.2 Uninstalling Atomix - PASS
- 23.3 Uninstalling ONOS package - PASS
- 23.4 Installing Atomix - PASS
- 23.5 Installing ONOS package - PASS
- 23.6 Set up ONOS secure SSH - PASS
- 23.7 Checking ONOS service - PASS
- 23.8 Starting ONOS CLI sessions - PASS
- 23.9 Checking ONOS nodes - PASS
- 23.10 Checking ONOS applications - PASS
- 23.11 Starting Mininet Topology - PASS
- 23.12 Check whether the flow count is bigger than 106 - PASS
- 23.13 Check whether all flow status are ADDED - PASS
- 23.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE23_Before - PASS
- 23.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE23_Before - PASS
- 23.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 23.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 23.18 Check whether the flow count is bigger than 106 - PASS
- 23.19 Check whether all flow status are ADDED - PASS
FAIL
- Flow status is wrong!
- 23.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE23_After - PASS
- 23.21 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE23_After - PASS
- 23.22 Stopping Mininet - PASS
- 23.23 Copying karaf logs - PASS
...
- 123.1 Apply cell to environment - PASS
- 123.2 Uninstalling Atomix - PASS
- 123.3 Uninstalling ONOS package - PASS
- 123.4 Installing Atomix - PASS
- 123.5 Installing ONOS package - PASS
- 123.6 Set up ONOS secure SSH - PASS
- 123.7 Checking ONOS service - PASS
- 123.8 Starting ONOS CLI sessions - PASS
- 123.9 Checking ONOS nodes - PASS
- 123.10 Checking ONOS applications - PASS
- 123.11 Starting Mininet Topology - PASS
- 123.12 Check whether the flow count is bigger than 104 - PASS
- 123.13 Check whether all flow status are ADDED - PASS
- 123.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE123_Before - PASS
- 123.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE123_Before - PASS
- 123.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 123.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 123.18 Check whether the flow count is bigger than 104 - PASS
- 123.19 Check whether all flow status are ADDED - PASS
- 123.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE123_After - PASS
- 123.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE123_After - PASS
- 123.22 Stopping Mininet - PASS
- 123.23 Copying karaf logs - PASS
Case 133: Changing port configuration from tagged 20 and native 10 to tagged 120 and native 10, with 2x2 leaf-spine topology and 3 ONOS instances -
...
FAIL
- 133.1 Apply cell to environment - PASS
- 133.2 Uninstalling Atomix - PASS
- 133.3 Uninstalling ONOS package - PASS
- 133.4 Installing Atomix - PASS
- 133.5 Installing ONOS package - PASS
- 133.6 Set up ONOS secure SSH - PASS
- 133.7 Checking ONOS service - PASS
- 133.8 Starting ONOS CLI sessions - PASS
- 133.9 Checking ONOS nodes - PASS
- 133.10 Checking ONOS applications - PASS
- 133.11 Starting Mininet Topology - PASS
- 133.12 Check whether the flow count is bigger than 104 - PASS
FAIL
- Flow count looks wrong: False
- 133.13 Check whether all flow status are ADDED - PASS
- 133.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE133_Before - PASS
FAIL
- IP connectivity failed
- 133.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE133_Before - PASS
FAIL
- IP connectivity failed
- 133.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
FAIL
- Flow count looks wrong.
- 133.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
FAIL
- Flow count looks wrong.
- 133.18 Check whether the flow count is bigger than 104 - PASS
FAIL
- Flow count looks wrong: False
- 133.19 Check whether all flow status are ADDED - PASS
- 133.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE133_After - PASS
FAIL
- IP connectivity failed
- 133.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE133_After - PASS
FAIL
- IP connectivity failed
- 133.22 Stopping Mininet - PASS
- 133.23 Copying karaf logs - PASS
...