Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Published from Jenkins build: https://jenkins.onosproject.org/job/SR-pipeline-master/190/

...

HTML
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric4/lastSuccessfulBuild/artifact/SRDynamicConf_master_20-builds_graph.jpg", alt="SRDynamicConf", style="width:525px;height:350px;border:0">

commit e3141545bae9480dc9f7a7158f8cc1d55912b121 7981a32f37d64225a5b641725ba172cdc32e2f0d (HEAD -] master, origin/master, origin/HEAD)
Author: Jian Li Ray Milkey [pyguni@gmailray@opennetworking.comorg]
AuthorDate: Mon Thu Aug 13 1816 14:0555:43 46 2018 +0900-0700
Commit: Jian Li Ray Milkey [pyguni@gmailray@opennetworking.comorg]
CommitDate: Thu Aug 16 0123:5852:10 44 2018 +0000
Auto-generate an intg-bridge ID if it is not specified via net-cfg
Fix NPE when component can't be found

Case 13: Changing port configuration from untagged 10 to tagged 10, with 2x2 leaf-spine topology and 3 ONOS instances - PASS

...

  • 13.1 Constructing test variables - PASS (tick)
  • 13.2 Apply cell to environment - PASS (tick)
  • 13.3 Uninstalling Atomix - PASS (tick)
  • 13.4 Uninstalling ONOS package - PASS (tick)
  • 13.5 Creating ONOS package - PASS (tick)
  • 13.6 Installing Atomix - PASS (tick)
  • 13.7 Installing ONOS package - PASS (tick)
  • 13.8 Set up ONOS secure SSH - PASS (tick)
  • 13.9 Checking ONOS service - PASS (tick)
  • 13.10 Starting ONOS CLI sessions - PASS (tick)
  • 13.11 Checking ONOS nodes - PASS (tick)
  • 13.12 Checking ONOS applications - PASS (tick)
  • 13.13 Starting Mininet Topology - PASS (tick)
  • 13.14 Check whether the flow count is bigger than 104 - PASS (tick)
  • 13.15 Check whether all flow status are ADDED - PASS (tick)
  • 13.16 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE13_Before - PASS (tick)
  • 13.17 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 13.18 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 13.19 Check whether the flow count is bigger than 104 - PASS (tick)
  • 13.20 Check whether all flow status are ADDED - PASS (tick)
  • 13.21 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE13_After - PASS (tick)
  • 13.22 Stopping Mininet - PASS (tick)
  • 13.23 Copying karaf logs - PASS (tick)

Case 23: Changing port configuration from untagged 10 to tagged 20 and native 10, with 2x2 leaf-spine topology and 3 ONOS instances -

...

PASS

  • 23.1 Apply cell to environment - PASS (tick)
  • 23.2 Uninstalling Atomix - PASS (tick)
  • 23.3 Uninstalling ONOS package - PASS (tick)
  • 23.4 Installing Atomix - PASS (tick)
  • 23.5 Installing ONOS package - PASS (tick)
  • 23.6 Set up ONOS secure SSH - PASS (tick)
  • 23.7 Checking ONOS service - PASS (tick)
  • 23.8 Starting ONOS CLI sessions - PASS (tick)
  • 23.9 Checking ONOS nodes - PASS (tick)
  • 23.10 Checking ONOS applications - PASS (tick)
  • 23.11 Starting Mininet Topology - PASS (tick)
  • 23.12 Check whether the flow count is bigger than 106 - PASS (tick)
  • 23.13 Check whether all flow status are ADDED - PASS (tick)
  • 23.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE23_Before - PASS (tick)
  • 23.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE23_Before - PASS (tick)
  • 23.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 23.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 23.18 Check whether the flow count is bigger than 106 - PASS (tick)
  • 23.19 Check whether all flow status are ADDED - FAIL (error)
  • Flow status is wrong!
  • PASS (tick)
  • 23.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE23_After - PASS (tick)
  • 23.21 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE23_After - PASS (tick)
  • 23.22 Stopping Mininet - PASS (tick)
  • 23.23 Copying karaf logs - PASS (tick)

...

  • 123.1 Apply cell to environment - PASS (tick)
  • 123.2 Uninstalling Atomix - PASS (tick)
  • 123.3 Uninstalling ONOS package - PASS (tick)
  • 123.4 Installing Atomix - PASS (tick)
  • 123.5 Installing ONOS package - PASS (tick)
  • 123.6 Set up ONOS secure SSH - PASS (tick)
  • 123.7 Checking ONOS service - PASS (tick)
  • 123.8 Starting ONOS CLI sessions - PASS (tick)
  • 123.9 Checking ONOS nodes - PASS (tick)
  • 123.10 Checking ONOS applications - PASS (tick)
  • 123.11 Starting Mininet Topology - PASS (tick)
  • 123.12 Check whether the flow count is bigger than 104 - PASS (tick)
  • 123.13 Check whether all flow status are ADDED - PASS (tick)
  • 123.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE123_Before - PASS (tick)
  • 123.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE123_Before - PASS (tick)
  • 123.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 123.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 123.18 Check whether the flow count is bigger than 104 - PASS (tick)
  • 123.19 Check whether all flow status are ADDED - PASS (tick)
  • 123.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE123_After - PASS (tick)
  • 123.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE123_After - PASS (tick)
  • 123.22 Stopping Mininet - PASS (tick)
  • 123.23 Copying karaf logs - PASS (tick)

Case 133: Changing port configuration from tagged 20 and native 10 to tagged 120 and native 10, with 2x2 leaf-spine topology and 3 ONOS instances -

...

PASS

  • 133.1 Apply cell to environment - PASS (tick)
  • 133.2 Uninstalling Atomix - PASS (tick)
  • 133.3 Uninstalling ONOS package - PASS (tick)
  • 133.4 Installing Atomix - PASS (tick)
  • 133.5 Installing ONOS package - PASS (tick)
  • 133.6 Set up ONOS secure SSH - PASS (tick)
  • 133.7 Checking ONOS service - PASS (tick)
  • 133.8 Starting ONOS CLI sessions - PASS (tick)
  • 133.9 Checking ONOS nodes - PASS (tick)
  • 133.10 Checking ONOS applications - PASS (tick)
  • 133.11 Starting Mininet Topology - PASS (tick)
  • 133.12 Check whether the flow count is bigger than 104 - FAIL (error)
  • Flow count looks wrong: False
  • PASS (tick)
  • 133.13 Check whether all flow status are ADDED - PASS (tick)
  • 133.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE133_Before - FAIL (error)
    • IP connectivity failed
  • PASS (tick)
  • 133.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE133_Before - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 133.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - FAIL (error)
    • Flow count looks wrong.
  • PASS (tick)
  • 133.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - FAIL (error)
  • Flow count looks wrong.
  • PASS (tick)
  • 133.18 Check whether the flow count is bigger than 104 - FAIL (error)
    • Flow count looks wrong: False
  • PASS (tick)
  • 133.19 Check whether all flow status are ADDED - PASS (tick)
  • 133.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE133_After - FAIL (error)
    • IP connectivity failed
  • PASS (tick)
  • 133.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE133_After - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 133.22 Stopping Mininet - PASS (tick)
  • 133.23 Copying karaf logs - PASS (tick)

...