  • 1.1 Constructing test variables - PASS (tick)
  • 1.2 Apply cell to environment - PASS (tick)
  • 1.3 Uninstalling Atomix - PASS (tick)
  • 1.4 Uninstalling ONOS package - PASS (tick)
  • 1.5 Building ONOS Docker image - PASS (tick)
  • 1.6 Create Cluster Config - PASS (tick)
  • 1.7 Installing Atomix via docker containers - PASS (tick)
  • 1.8 Installing ONOS via docker containers - PASS (tick)
  • 1.9 Set up ONOS secure SSH - PASS (tick)
  • 1.10 Starting ONOS CLI sessions - PASS (tick)
  • 1.11 Checking ONOS nodes - PASS (tick)
  • 1.12 Checking ONOS applications - PASS (tick)
  • 1.13 Set logging levels - PASS (tick)
  • 1.14 Set ONOS configurations - PASS (tick)
  • 1.15 Starting Mininet Topology - PASS (tick)
  • 1.16 Configure switches in ONOS - PASS (tick)
  • 1.17 Check number of topology elements - FAIL (error)
    • Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
    • ONOS sees 4 devices (4 expected) and 0 links (8 expected) and 1 controllers (1 expected) and 4 SCCs (1 expected)
  • 1.18 Check whether the flow count is >= 116 - FAIL (error)
    • Flow count looks wrong; found 610, expecting at least 116
  • 1.19 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 1.20 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.21 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.22 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.23 Kill link between spine101 and leaf2 - PASS (tick)
  • 1.24 Checking topology after link down - FAIL (error)
    • Topology after link down is incorrect
  • 1.25 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_Failure - FAIL (error)
    • IP connectivity failed
  • 1.26 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_Failure - FAIL (error)
    • IP connectivity failed
  • 1.27 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_Failure - FAIL (error)
    • IP connectivity failed
  • 1.28 Restore link between spine101 and leaf2 - FAIL (error)
    • Failed to bring link up
  • 1.29 Check whether the flow count is >= 116 - FAIL (error)
    • Flow count looks wrong; found 610, expecting at least 116
  • 1.30 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 1.31 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_Recovery - FAIL (error)
    • IP connectivity failed
  • 1.32 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_Recovery - FAIL (error)
    • IP connectivity failed
  • 1.33 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_Recovery - FAIL (error)
    • IP connectivity failed
  • 1.34 Check number of topology elements - FAIL (error)
    • Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
    • ONOS sees 4 devices (4 expected) and 0 links (8 expected) and 1 controllers (1 expected) and 4 SCCs (1 expected)
  • 1.35 Stopping Mininet - PASS (tick)
  • 1.36 Copying karaf logs - PASS (tick)

...