Due to a ransomware attack, the wiki was reverted to a July 2022 version. . We apologize for the lack of a more recent valid backup.
...
HTML |
---|
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric4/lastSuccessfulBuild/artifact/SRBridging_master_20-builds_graph.jpg", alt="SRBridging", style="width:525px;height:350px;border:0"> |
commit f381442fa36a59c4515e2671025322e46e647594 66bf3824ea7fb488411cd1d7b3f1c69e617faa78 (HEAD -] master, origin/master, origin/HEAD)
Author: Ray Milkey [ray@opennetworking.org]
AuthorDate: Mon Tue Sep 17 1418 16:4755:23 56 2018 -0700
Commit: Ray Milkey [ray@opennetworking.org]
CommitDate: Mon Tue Sep 17 2218 16:4855:18 56 2018 +0000
Allow using the 0.17 version of bazel-0700
Remove deprecated Host Provider APIs
Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR and 3 ONOS instances - PASS
...
- 16.1 Apply cell to environment - PASS
- 16.2 Uninstalling Atomix - PASS
- 16.3 Uninstalling ONOS package - PASS
- 16.4 Installing Atomix - PASS
- 16.5 Installing ONOS package - PASS
- 16.6 Set up ONOS secure SSH - PASS
- 16.7 Checking ONOS service - PASS
- 16.8 Starting ONOS CLI sessions - PASS
- 16.9 Checking ONOS nodes - PASS
- 16.10 Checking ONOS applications - PASS
- 16.11 Starting Mininet Topology - PASS
- 16.12 Check whether the flow count is bigger than 74 - PASS
- 16.13 Check whether all flow status are ADDED - PASS
- 16.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 16.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 16.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE16 - PASS
- 16.17 Stopping Mininet - PASS
- 16.18 Copying karaf logs - PASS
Case 17: Bridging test between two tagged hosts, with 2x2 leaf-spine topology and 3 ONOS instances -
...
FAIL
- 17.1 Apply cell to environment - PASS
- 17.2 Uninstalling Atomix - PASS
- 17.3 Uninstalling ONOS package - PASS
- 17.4 Installing Atomix - PASS
- 17.5 Installing ONOS package - PASS
- 17.6 Set up ONOS secure SSH - PASS
- 17.7 Checking ONOS service - PASS
- 17.8 Starting ONOS CLI sessions - PASS
- 17.9 Checking ONOS nodes - PASS
- 17.10 Checking ONOS applications - PASS
- 17.11 Starting Mininet Topology - PASS
- 17.12 Check whether the flow count is bigger than 74 - PASS
- 17.13 Check whether all flow status are ADDED - PASS
FAIL
- Flow status is wrong!
- 17.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
FAIL
- Flow count looks wrong.
- 17.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 17.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE17 - PASS
FAIL
- IP connectivity failed
- 17.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE17 - PASS
- 17.18 Stopping Mininet - PASS
- 17.19 Copying karaf logs - PASS
Case 18: Bridging test between two tagged hosts, with 2x4 dual-homed leaf-spine topology and 3 ONOS instances -
...
FAIL
- 18.1 Apply cell to environment - PASS
- 18.2 Uninstalling Atomix - PASS
- 18.3 Uninstalling ONOS package - PASS
- 18.4 Installing Atomix - PASS
- 18.5 Installing ONOS package - PASS
- 18.6 Set up ONOS secure SSH - PASS
- 18.7 Checking ONOS service - PASS
- 18.8 Starting ONOS CLI sessions - PASS
- 18.9 Checking ONOS nodes - PASS
- 18.10 Checking ONOS applications - PASS
- 18.11 Starting Mininet Topology - PASS
- 18.12 Check whether the flow count is bigger than 212 - PASS
- 18.13 Check whether all flow status are ADDED - PASS
FAIL
- Flow status is wrong!
- 18.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
FAIL
- Flow count looks wrong.
- 18.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 18.16 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS
FAIL
- Flow count looks wrong.
- 18.17 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS
- 18.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE18 - PASS
FAIL
- IP connectivity failed
- 18.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE18 - PASS
FAIL
- IP connectivity failed
- 18.20 Stopping Mininet - PASS
- 18.21 Copying karaf logs - PASS
...
- 25.1 Apply cell to environment - PASS
- 25.2 Uninstalling Atomix - PASS
- 25.3 Uninstalling ONOS package - PASS
- 25.4 Installing Atomix - PASS
- 25.5 Installing ONOS package - PASS
- 25.6 Set up ONOS secure SSH - PASS
- 25.7 Checking ONOS service - PASS
- 25.8 Starting ONOS CLI sessions - PASS
- 25.9 Checking ONOS nodes - PASS
- 25.10 Checking ONOS applications - PASS
- 25.11 Starting Mininet Topology - PASS
- 25.12 Check whether the flow count is bigger than 28 - PASS
- 25.13 Check whether all flow status are ADDED - PASS
- 25.14 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS
- 25.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE25 - PASS
- 25.16 Stopping Mininet - PASS
- 25.17 Copying karaf logs - PASS
Case 26: Bridging test between two untagged hosts on vlan-native port, with dual-homed ToR and 3 ONOS instances -
...
FAIL
- 26.1 Apply cell to environment - PASS
- 26.2 Uninstalling Atomix - PASS
- 26.3 Uninstalling ONOS package - PASS
- 26.4 Installing Atomix - PASS
- 26.5 Installing ONOS package - PASS
- 26.6 Set up ONOS secure SSH - PASS
- 26.7 Checking ONOS service - PASS
- 26.8 Starting ONOS CLI sessions - PASS
- 26.9 Checking ONOS nodes - PASS
- 26.10 Checking ONOS applications - PASS
- 26.11 Starting Mininet Topology - PASS
- 26.12 Check whether the flow count is bigger than 74 - PASS
- 26.13 Check whether all flow status are ADDED - PASS
FAIL
- Flow status is wrong!
- 26.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
FAIL
- Flow count looks wrong.
- 26.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 26.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE26 - PASS
FAIL
- IP connectivity failed
- 26.17 Stopping Mininet - PASS
- 26.18 Copying karaf logs - PASS
Case 27: Bridging test between two untagged hosts on vlan-native port, with 2x2 leaf-spine topology and 3 ONOS instances -
...
FAIL
- 27.1 Apply cell to environment - PASS
- 27.2 Uninstalling Atomix - PASS
- 27.3 Uninstalling ONOS package - PASS
- 27.4 Installing Atomix - PASS
- 27.5 Installing ONOS package - PASS
- 27.6 Set up ONOS secure SSH - PASS
- 27.7 Checking ONOS service - PASS
- 27.8 Starting ONOS CLI sessions - PASS
- 27.9 Checking ONOS nodes - PASS
- 27.10 Checking ONOS applications - PASS
- 27.11 Starting Mininet Topology - PASS
- 27.12 Check whether the flow count is bigger than 74 - PASS
- 27.13 Check whether all flow status are ADDED - PASS
FAIL
- Flow status is wrong!
- 27.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
FAIL
- Flow count looks wrong.
- 27.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
FAIL
- Flow count looks wrong.
- 27.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE27 - PASS
FAIL
- IP connectivity failed
- 27.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE27 - PASS
FAIL
- IP connectivity failed
- 27.18 Stopping Mininet - PASS
- 27.19 Copying karaf logs - PASS
...
- 35.1 Apply cell to environment - PASS
- 35.2 Uninstalling Atomix - PASS
- 35.3 Uninstalling ONOS package - PASS
- 35.4 Installing Atomix - PASS
- 35.5 Installing ONOS package - PASS
- 35.6 Set up ONOS secure SSH - PASS
- 35.7 Checking ONOS service - PASS
- 35.8 Starting ONOS CLI sessions - PASS
- 35.9 Checking ONOS nodes - PASS
- 35.10 Checking ONOS applications - PASS
- 35.11 Starting Mininet Topology - PASS
- 35.12 Check whether the flow count is bigger than 28 - PASS
- 35.13 Check whether all flow status are ADDED - PASS
- 35.14 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS
- 35.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE35 - PASS
- 35.16 Stopping Mininet - PASS
- 35.17 Copying karaf logs - PASS
Case 36: Bridging test between two untagged hosts, one on vlan-untagged port and the other on vlan-native port, with dual-homed ToR and 3 ONOS instances -
...
FAIL
- 36.1 Apply cell to environment - PASS
- 36.2 Uninstalling Atomix - PASS
- 36.3 Uninstalling ONOS package - PASS
- 36.4 Installing Atomix - PASS
- 36.5 Installing ONOS package - PASS
- 36.6 Set up ONOS secure SSH - PASS
- 36.7 Checking ONOS service - PASS
- 36.8 Starting ONOS CLI sessions - PASS
- 36.9 Checking ONOS nodes - PASS
- 36.10 Checking ONOS applications - PASS
- 36.11 Starting Mininet Topology - PASS
- 36.12 Check whether the flow count is bigger than 74 - PASS
- 36.13 Check whether all flow status are ADDED - PASS
FAIL
- Flow status is wrong!
- 36.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 36.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
FAIL
- Flow count looks wrong.
- 36.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE36 - PASS
FAIL
- IP connectivity failed
- 36.17 Stopping Mininet - PASS
- 36.18 Copying karaf logs - PASS
Case 37: Bridging test between two untagged hosts, one on vlan-untagged port and the other on vlan-native port, with 2x2 leaf-spine topology and 3 ONOS instances -
...
FAIL
- 37.1 Apply cell to environment - PASS
- 37.2 Uninstalling Atomix - PASS
- 37.3 Uninstalling ONOS package - PASS
- 37.4 Installing Atomix - PASS
- 37.5 Installing ONOS package - PASS
- 37.6 Set up ONOS secure SSH - PASS
- 37.7 Checking ONOS service - PASS
- 37.8 Starting ONOS CLI sessions - PASS
- 37.9 Checking ONOS nodes - PASS
- 37.10 Checking ONOS applications - PASS
- 37.11 Starting Mininet Topology - PASS
- 37.12 Check whether the flow count is bigger than 74 - PASS
- 37.13 Check whether all flow status are ADDED - PASS
FAIL
- Flow status is wrong!
- 37.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 37.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
FAIL
- Flow count looks wrong.
- 37.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE37 - PASS
- 37.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE37 - PASS
FAIL
- IP connectivity failed
- 37.18 Stopping Mininet - PASS
- 37.19 Copying karaf logs - PASS
...
- 46.1 Apply cell to environment - PASS
- 46.2 Uninstalling Atomix - PASS
- 46.3 Uninstalling ONOS package - PASS
- 46.4 Installing Atomix - PASS
- 46.5 Installing ONOS package - PASS
- 46.6 Set up ONOS secure SSH - PASS
- 46.7 Checking ONOS service - PASS
- 46.8 Starting ONOS CLI sessions - PASS
- 46.9 Checking ONOS nodes - PASS
- 46.10 Checking ONOS applications - PASS
- 46.11 Starting Mininet Topology - PASS
- 46.12 Check whether the flow count is bigger than 74 - PASS
- 46.13 Check whether all flow status are ADDED - PASS
- 46.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 46.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 46.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE46 - PASS
- 46.17 Stopping Mininet - PASS
- 46.18 Copying karaf logs - PASS
Case 47: Bridging test between untagged host and tagged host, with 2x2 leaf-spine topology and 3 ONOS instances -
...
FAIL
- 47.1 Apply cell to environment - PASS
- 47.2 Uninstalling Atomix - PASS
- 47.3 Uninstalling ONOS package - PASS
- 47.4 Installing Atomix - PASS
- 47.5 Installing ONOS package - PASS
- 47.6 Set up ONOS secure SSH - PASS
- 47.7 Checking ONOS service - PASS
- 47.8 Starting ONOS CLI sessions - PASS
- 47.9 Checking ONOS nodes - PASS
- 47.10 Checking ONOS applications - PASS
- 47.11 Starting Mininet Topology - PASS
- 47.12 Check whether the flow count is bigger than 74 - PASS
- 47.13 Check whether all flow status are ADDED - PASS
FAIL
- Flow status is wrong!
- 47.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 47.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 47.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE47 - PASS
- 47.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE47 - PASS
- 47.18 Stopping Mininet - PASS
- 47.19 Copying karaf logs - PASS
...
- 56.1 Apply cell to environment - PASS
- 56.2 Uninstalling Atomix - PASS
- 56.3 Uninstalling ONOS package - PASS
- 56.4 Installing Atomix - PASS
- 56.5 Installing ONOS package - PASS
- 56.6 Set up ONOS secure SSH - PASS
- 56.7 Checking ONOS service - PASS
- 56.8 Starting ONOS CLI sessions - PASS
- 56.9 Checking ONOS nodes - PASS
- 56.10 Checking ONOS applications - PASS
- 56.11 Starting Mininet Topology - PASS
- 56.12 Check whether the flow count is bigger than 74 - PASS
- 56.13 Check whether all flow status are ADDED - PASS
- 56.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 56.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 56.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE56 - PASS
- 56.17 Stopping Mininet - PASS
- 56.18 Copying karaf logs - PASS
Case 57: Bridging test between two untagged hosts with different vlan id, with 2x2 leaf-spine topology and 3 ONOS instances -
...
FAIL
- 57.1 Apply cell to environment - PASS
- 57.2 Uninstalling Atomix - PASS
- 57.3 Uninstalling ONOS package - PASS
- 57.4 Installing Atomix - PASS
- 57.5 Installing ONOS package - PASS
- 57.6 Set up ONOS secure SSH - PASS
- 57.7 Checking ONOS service - PASS
- 57.8 Starting ONOS CLI sessions - PASS
- 57.9 Checking ONOS nodes - PASS
- 57.10 Checking ONOS applications - PASS
- 57.11 Starting Mininet Topology - PASS
- 57.12 Check whether the flow count is bigger than 74 - PASS
- 57.13 Check whether all flow status are ADDED - PASS
FAIL
- Flow status is wrong!
- 57.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 57.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
FAIL
- Flow count looks wrong.
- 57.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE57 - PASS
- 57.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE57 - PASS
- 57.18 Stopping Mininet - PASS
- 57.19 Copying karaf logs - PASS
Case 58: Bridging test between two untagged hosts with different vlan id, with 2x4 dual-homed leaf-spine topology and 3 ONOS instances -
...
FAIL
- 58.1 Apply cell to environment - PASS
- 58.2 Uninstalling Atomix - PASS
- 58.3 Uninstalling ONOS package - PASS
- 58.4 Installing Atomix - PASS
- 58.5 Installing ONOS package - PASS
- 58.6 Set up ONOS secure SSH - PASS
- 58.7 Checking ONOS service - PASS
- 58.8 Starting ONOS CLI sessions - PASS
- 58.9 Checking ONOS nodes - PASS
- 58.10 Checking ONOS applications - PASS
- 58.11 Starting Mininet Topology - PASS
- 58.12 Check whether the flow count is bigger than 212 - PASS
- 58.13 Check whether all flow status are ADDED - PASS
FAIL
- Flow status is wrong!
- 58.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 58.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
FAIL
- Flow count looks wrong.
- 58.16 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS
FAIL
- Flow count looks wrong.
- 58.17 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS
FAIL
- Flow count looks wrong.
- 58.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE58 - PASS
- 58.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE58 - PASS
- 58.20 Stopping Mininet - PASS
- 58.21 Copying karaf logs - PASS
...
- 77.1 Apply cell to environment - PASS
- 77.2 Uninstalling Atomix - PASS
- 77.3 Uninstalling ONOS package - PASS
- 77.4 Installing Atomix - PASS
- 77.5 Installing ONOS package - PASS
- 77.6 Set up ONOS secure SSH - PASS
- 77.7 Checking ONOS service - PASS
- 77.8 Starting ONOS CLI sessions - PASS
- 77.9 Checking ONOS nodes - PASS
- 77.10 Checking ONOS applications - PASS
- 77.11 Starting Mininet Topology - PASS
- 77.12 Check whether the flow count is bigger than 74 - PASS
- 77.13 Check whether all flow status are ADDED - PASS
- 77.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 77.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 77.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE77 - PASS
- 77.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE77 - PASS
- 77.18 Stopping Mininet - PASS
- 77.19 Copying karaf logs - PASS
Case 78: Bridging test between untagged and tagged hosts with different vlan id, with 2x4 dual-homed leaf-spine topology and 3 ONOS instances -
...
FAIL
- 78.1 Apply cell to environment - PASS
- 78.2 Uninstalling Atomix - PASS
- 78.3 Uninstalling ONOS package - PASS
- 78.4 Installing Atomix - PASS
- 78.5 Installing ONOS package - PASS
- 78.6 Set up ONOS secure SSH - PASS
- 78.7 Checking ONOS service - PASS
- 78.8 Starting ONOS CLI sessions - PASS
- 78.9 Checking ONOS nodes - PASS
- 78.10 Checking ONOS applications - PASS
- 78.11 Starting Mininet Topology - PASS
- 78.12 Check whether the flow count is bigger than 212 - PASS
- 78.13 Check whether all flow status are ADDED - PASS
FAIL
- Flow status is wrong!
- 78.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
FAIL
- Flow count looks wrong.
- 78.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 78.16 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS
FAIL
- Flow count looks wrong.
- 78.17 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS
- 78.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE78 - PASS
- 78.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE78 - PASS
- 78.20 Stopping Mininet - PASS
- 78.21 Copying karaf logs - PASS