commit d15c5f63f779ce070e0c4e25020059aef7ff18fe da3b9f09807e4054835495b1d61b3956ef5c5cbd (HEAD -] master, origin/master, origin/HEAD)
Author: Jordan Halterman [jordan@opennetworking.org]
AuthorDate: Wed Fri Oct 3 165 13:0928:24 51 2018 -0700
Commit: Ray Milkey Charles Chan [ray@opennetworkingcharles@opennetworking.org]
CommitDate: Sat Tue Oct 6 039 17:3224:55 35 2018 +0000
[ONOS-7801] Avoid converting local node on every lookup in ClusterStore
Avoid closing DeviceFlowTable when flows are purged on device down event
--
(cherry picked from commit cd4276521ca0a7268353317ede37de33cdbe4c52)
Case 13: Changing port configuration from untagged 10 to tagged 10, with 2x2 leaf-spine topology and 3 ONOS instances - PASS
...
- 233.1 Apply cell to environment - PASS
- 233.2 Uninstalling Atomix - PASS
- 233.3 Uninstalling ONOS package - PASS
- 233.4 Installing Atomix - PASS
- 233.5 Installing ONOS package - PASS
- 233.6 Set up ONOS secure SSH - PASS
- 233.7 Checking ONOS service - PASS
- 233.8 Starting ONOS CLI sessions - PASS
- 233.9 Checking ONOS nodes - PASS
- 233.10 Checking ONOS applications - PASS
- 233.11 Starting Mininet Topology - PASS
- 233.12 Check whether the flow count is bigger than 104 - FAIL
- Flow count looks wrong: False
- PASS
- 233.13 Check whether all flow status are ADDED - PASS
- 233.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_Before - FAIL
- PASS
- 233.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_Before - FAIL
- PASS
- 233.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - FAIL
- PASS
- 233.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - FAIL
- PASS
- 233.18 Check whether the flow count of device of:0000000000000001 is bigger than 52 - FAIL
- PASS
- 233.19 Check whether the flow count of device of:0000000000000002 is bigger than 52 - FAIL
- Flow count looks wrong.
- PASS
- 233.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_1 - FAIL
- PASS
- 233.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_1 - PASS
- 233.22 Check whether the flow count of device of:0000000000000001 is bigger than 52 - FAIL
- PASS
- 233.23 Check whether the flow count of device of:0000000000000002 is bigger than 52 - FAIL
- PASS
- 233.24 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_2 - FAIL
- PASS
- 233.25 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_2 - PASS
- 233.26 Check whether the flow count of device of:0000000000000001 is bigger than 52 - FAIL
- PASS
- 233.27 Check whether the flow count of device of:0000000000000002 is bigger than 52 - FAIL
- PASS
- 233.28 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_3 - FAIL
- PASS
- 233.29 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_3 - PASS
- 233.30 Check whether the flow count of device of:0000000000000001 is bigger than 52 - FAIL
- PASS
- 233.31 Check whether the flow count of device of:0000000000000002 is bigger than 52 - FAIL
- Flow count looks wrong.
- PASS
- 233.32 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_4 - FAIL
- PASS
- 233.33 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_4 - FAIL
- IP connectivity failed
- 233.34 Check whether the flow count of device of:0000000000000001 is bigger than 52 - FAIL
- Flow count looks wrong.
- PASS
- 233.35 Check whether the flow count of device of:0000000000000002 is bigger than 52 - FAIL
- PASS
- 233.36 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_5 - FAIL
- PASS
- 233.37 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_5 - PASS
- 233.38 Check whether the flow count of device of:0000000000000001 is bigger than 52 - FAIL
- PASS
- 233.39 Check whether the flow count of device of:0000000000000002 is bigger than 52 - FAIL
- PASS
- 233.40 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_6 - FAIL
- IP connectivity failed
- PASS
- 233.41 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_6 - PASS
- 233.42 Check whether the flow count of device of:0000000000000001 is bigger than 52 - FAIL
- PASS
- 233.43 Check whether the flow count of device of:0000000000000002 is bigger than 52 - FAIL
- Flow count looks wrong.
- PASS
- 233.44 Check whether the flow count is bigger than 104 - FAIL
- PASS
- 233.45 Check whether all flow status are ADDED - PASS
- 233.46 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_After - FAIL
- PASS
- 233.47 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_After - FAIL
- IP connectivity failed
- 233.48 Stopping Mininet - PASS
- 233.49 Copying karaf logs - PASS
...