Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Published from Jenkins build: https://jenkins.onosproject.org/job/SR-pipeline-master/336/

...

HTML
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric4/lastSuccessfulBuild/artifact/SRDynamic_master_20-builds_graph.jpg", alt="SRDynamic", style="width:525px;height:350px;border:0">

commit 27e94e4057b0ee7f9bf12c16bdc7d047718791f6 a80d3f95532f8f0d94c642dabb4dd17d78c8c11b (HEAD -] master, origin/master, origin/HEAD)
Author: Jon Hall Jordan Halterman [jhall@cienajordan@opennetworking.comorg]
AuthorDate: Tue Wed Jan 8 16 18:1728:24 14 2019 -0800
Commit: Ray Milkey [ray@opennetworking.org]
CommitDate: Thu Jan 10 17 23:3002:39 05 2019 +0000
Allow use of rsync when fetching logs
--
(cherry picked from commit 359f4d84608c44541c43bfc564893ac76c326063)

Upgrade to Atomix 3.1.5

Case 1: Bridging and Routing sanity test with 2x2 Leaf-spineand 1 nodes. - FAIL

...

  • 1.1 Constructing test variables - PASS (tick)
  • 1.2 Apply cell to environment - PASS (tick)
  • 1.3 Uninstalling Atomix - PASS (tick)
  • 1.4 Uninstalling ONOS package - PASS (tick)
  • 1.5 Creating ONOS package - PASS (tick)
  • 1.6 Installing Atomix - PASS (tick)
  • 1.7 Installing ONOS package - PASS (tick)
  • 1.8 Set up ONOS secure SSH - PASS (tick)
  • 1.9 Checking ONOS service - PASS (tick)
  • 1.10 Starting ONOS CLI sessions - PASS (tick)
  • 1.11 Checking ONOS nodes - PASS (tick)
  • 1.12 Checking ONOS applications - PASS (tick)
  • 1.13 Starting Mininet Topology - PASS (tick)
  • 1.14 Check whether the flow count is bigger than 116 - PASS (tick)
  • 1.15 Check whether all flow status are ADDED - PASS (tick)
  • 1.16 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.17 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1 - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 1.18 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1 - PASS (tick)
  • 1.19 Pushing new configuration - No Result (warning)
  • 1.20 Pushing new configuration - No Result (warning)
  • 1.21 Check whether the flow count is bigger than 140 - PASS (tick)
  • 1.22 Check whether all flow status are ADDED - PASS (tick)
  • 1.23 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', 'in1', 'out1'] with tag CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.24 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1 - PASS (tick)
  • 1.25 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1 - PASS (tick)
  • 1.26 Verify full connectivity for ['olt1', 'vsg1'] with tag CASE1 - PASS (tick)
  • 1.27 Stopping Mininet - PASS (tick)
  • 1.28 Copying karaf logs - PASS (tick)

...

  • 5.1 Apply cell to environment - PASS (tick)
  • 5.2 Uninstalling Atomix - PASS (tick)
  • 5.3 Uninstalling ONOS package - PASS (tick)
  • 5.4 Creating ONOS package - PASS (tick)
  • 5.5 Installing Atomix - PASS (tick)
  • 5.6 Installing ONOS package - PASS (tick)
  • 5.7 Set up ONOS secure SSH - PASS (tick)
  • 5.8 Checking ONOS service - PASS (tick)
  • 5.9 Starting ONOS CLI sessions - PASS (tick)
  • 5.10 Checking ONOS nodes - PASS (tick)
  • 5.11 Checking ONOS applications - PASS (tick)
  • 5.12 Starting Mininet Topology - PASS (tick)
  • 5.13 Check whether the flow count is bigger than 350 - PASS (tick)FAIL (error)
    • Flow count looks wrong: False
  • 5.14 Check whether all flow status are ADDED - PASS (tick)
  • 5.15 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE5 - FAIL (error)
    • IP connectivity failed
  • 5.16 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE5 - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 5.17 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE5 - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 5.18 Pushing new configuration - No Result (warning)
  • 5.19 Pushing new configuration - No Result (warning)
  • 5.20 Check whether the flow count is bigger than 380 - PASS (tick)FAIL (error)
    • Flow count looks wrong: False
  • 5.21 Check whether all flow status are ADDED - PASS (tick)
  • 5.22 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8', 'in1', 'out1'] with tag CASE5 - FAIL (error)
    • IP connectivity failed
  • 5.23 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE5 - PASS (tick)
  • 5.24 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE5 - PASS (tick)
  • 5.25 Verify full connectivity for ['olt1', 'vsg1'] with tag CASE5 - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 5.26 Killing ONOS instances with index(es): [0] - PASS (tick)
  • 5.27 Check number of topology elements - FAIL (error)
    • Unexpected number of links, switches, and/or controllers
  • 5.28 Removing host configuration - No Result (warning)
  • 5.29 Removing configuration - No Result (warning)
  • 5.30 Removing vlan configuration - No Result (warning)
  • 5.31 Check whether the flow count is bigger than 350 - PASS (tick)FAIL (error)
    • Flow count looks wrong: False
  • 5.32 Check whether all flow status are ADDED - PASS (tick)
  • 5.33 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8', 'in1', 'out1'] with tag CASE5_After - PASS (tick)
  • 5.34 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE5_After - PASS (tick)
  • 5.35 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE5_After - PASS (tick)
  • 5.36 Verify full connectivity for ['olt1', 'vsg1'] with tag CASE5_After - PASS (tick)
  • 5.37 Stopping Mininet - PASS (tick)
  • 5.38 Copying karaf logs - PASS (tick)

...