Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Published from Jenkins build: https://jenkins.onosproject.org/job/SR-pipeline-1.15/1076/

...

HTML
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric2/lastSuccessfulBuild/artifact/SRBridging_onos-1.15_20-builds_graph.jpg", alt="SRBridging", style="width:525px;height:350px;border:0">

commit 1baa550e3327039ecafcaf8c5936983f42fe8d3e 07e46f47e78385aa8933877d450596caf8c5897d (HEAD -] onos-1.15, origin/onos-1.15)
Author: Jian Li [pyguni@gmailSean Condon [sean.condon@microsemi.com]
AuthorDate: Fri Feb 1 10:14:34 2019 +0900Thu Jan 31 20:54:53 2019 +0000
Commit: Jian Li Andrea Campanella [pyguni@gmailandrea@opennetworking.comorg]
CommitDate: Fri Feb 1 11:0614:53 2019 +0900
Fix: resolve potential NPE issues reported by sonarcube18 2019 +0000

[ONOS-7907] Glyph specified for device not used in device table or device detail boxes
--
(cherry picked from commit 794d250740dcf2bdad65ad0f5ebe473d3093a266)

Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR and 3 ONOS instances - PASS

...

  • 65.1 Apply cell to environment - PASS (tick)
  • 65.2 Uninstalling Atomix - PASS (tick)
  • 65.3 Uninstalling ONOS package - PASS (tick)
  • 65.4 Installing Atomix - PASS (tick)
  • 65.5 Installing ONOS package - PASS (tick)
  • 65.6 Set up ONOS secure SSH - PASS (tick)
  • 65.7 Checking ONOS service - PASS (tick)
  • 65.8 Starting ONOS CLI sessions - PASS (tick)
  • 65.9 Checking ONOS nodes - PASS (tick)
  • 65.10 Checking ONOS applications - PASS (tick)
  • 65.11 Starting Mininet Topology - PASS (tick)
  • 65.12 Check whether the flow count is bigger than 28 - PASS (tick)
  • 65.13 Check whether all flow status are ADDED - PASS (tick)
  • 65.14 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS (tick)
  • 65.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE65 - PASS (tick)
  • 65.16 Stopping Mininet - PASS (tick)
  • 65.17 Copying karaf logs - PASS (tick)

Case 66: Bridging test between two tagged hosts with different vlan id, with dual-homed ToR and 3 ONOS instances -

...

PASS

  • 66.1 Apply cell to environment - PASS (tick)
  • 66.2 Uninstalling Atomix - PASS (tick)
  • 66.3 Uninstalling ONOS package - PASS (tick)
  • 66.4 Installing Atomix - PASS (tick)
  • 66.5 Installing ONOS package - PASS (tick)
  • 66.6 Set up ONOS secure SSH - PASS (tick)
  • 66.7 Checking ONOS service - PASS (tick)
  • 66.8 Starting ONOS CLI sessions - PASS (tick)
  • 66.9 Checking ONOS nodes - PASS (tick)
  • 66.10 Checking ONOS applications - PASS (tick)
  • 66.11 Starting Mininet Topology - PASS (tick)
  • 66.12 Check whether the flow count is bigger than 74 - PASS (tick)
  • 66.13 Check whether all flow status are ADDED - PASS (tick)
  • 66.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 66.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - FAIL (error)
    • Flow count looks wrong: 22
  • PASS (tick)
  • 66.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE66 - PASS (tick)
  • 66.17 Stopping Mininet - PASS (tick)
  • 66.18 Copying karaf logs - PASS (tick)

...

  • 77.1 Apply cell to environment - PASS (tick)
  • 77.2 Uninstalling Atomix - PASS (tick)
  • 77.3 Uninstalling ONOS package - PASS (tick)
  • 77.4 Installing Atomix - PASS (tick)
  • 77.5 Installing ONOS package - PASS (tick)
  • 77.6 Set up ONOS secure SSH - PASS (tick)
  • 77.7 Checking ONOS service - PASS (tick)
  • 77.8 Starting ONOS CLI sessions - PASS (tick)
  • 77.9 Checking ONOS nodes - PASS (tick)
  • 77.10 Checking ONOS applications - PASS (tick)
  • 77.11 Starting Mininet Topology - PASS (tick)
  • 77.12 Check whether the flow count is bigger than 74 - PASS (tick)
  • 77.13 Check whether all flow status are ADDED - PASS (tick)
  • 77.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 77.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 77.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE77 - PASS (tick)
  • 77.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE77 - PASS (tick)
  • 77.18 Stopping Mininet - PASS (tick)
  • 77.19 Copying karaf logs - PASS (tick)

Case 78: Bridging test between untagged and tagged hosts with different vlan id, with 2x4 dual-homed leaf-spine topology and 3 ONOS instances -

...

PASS

  • 78.1 Apply cell to environment - PASS (tick)
  • 78.2 Uninstalling Atomix - PASS (tick)
  • 78.3 Uninstalling ONOS package - PASS (tick)
  • 78.4 Installing Atomix - PASS (tick)
  • 78.5 Installing ONOS package - PASS (tick)
  • 78.6 Set up ONOS secure SSH - PASS (tick)
  • 78.7 Checking ONOS service - PASS (tick)
  • 78.8 Starting ONOS CLI sessions - PASS (tick)
  • 78.9 Checking ONOS nodes - PASS (tick)
  • 78.10 Checking ONOS applications - PASS (tick)
  • 78.11 Starting Mininet Topology - PASS (tick)
  • 78.12 Check whether the flow count is bigger than 212 - PASS (tick)
  • 78.13 Check whether all flow status are ADDED - PASS (tick)
  • 78.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 78.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - FAIL (error)
  • Flow count looks wrong: 17
  • PASS (tick)
  • 78.16 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS (tick)
  • 78.17 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS (tick)
  • 78.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE78 - PASS (tick)
  • 78.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE78 - PASS (tick)
  • 78.20 Stopping Mininet - PASS (tick)
  • 78.21 Copying karaf logs - PASS (tick)