  • 7.1 Apply cell to environment - PASS (tick)
  • 7.2 Uninstalling Atomix - PASS (tick)
  • 7.3 Uninstalling ONOS package - PASS (tick)
  • 7.4 Installing Atomix - PASS (tick)
  • 7.5 Installing ONOS package - PASS (tick)
  • 7.6 Set up ONOS secure SSH - PASS (tick)
  • 7.7 Checking ONOS service - PASS (tick)
  • 7.8 Starting ONOS CLI sessions - PASS (tick)
  • 7.9 Checking ONOS nodes - PASS (tick)
  • 7.10 Checking ONOS applications - PASS (tick)
  • 7.11 Starting Mininet Topology - PASS (tick)
  • 7.12 Check whether the flow count is bigger than 74 - PASS (tick)
  • 7.13 Check whether all flow status are ADDED - PASS (tick)
  • 7.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 7.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 7.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE7 - PASS (tick)
  • 7.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE7 - PASS (tick)
  • 7.18 Stopping Mininet - PASS (tick)
  • 7.19 Copying karaf logs - PASS (tick)

Case 8: Bridging test between two untagged hosts on vlan-untagged port, with 2x4 dual-homed leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 8.1 Apply cell to environment - PASS (tick)
  • 8.2 Uninstalling Atomix - PASS (tick)
  • 8.3 Uninstalling ONOS package - PASS (tick)
  • 8.4 Installing Atomix - PASS (tick)
  • 8.5 Installing ONOS package - PASS (tick)
  • 8.6 Set up ONOS secure SSH - PASS (tick)
  • 8.7 Checking ONOS service - PASS (tick)
  • 8.8 Starting ONOS CLI sessions - PASS (tick)
  • 8.9 Checking ONOS nodes - PASS (tick)
  • 8.10 Checking ONOS applications - PASS (tick)
  • 8.11 Starting Mininet Topology - PASS (tick)
  • 8.12 Check whether the flow count is bigger than 212 - PASS (tick)FAIL (error)
    • Flow count looks wrong: 102
  • 8.13 Check whether all flow status are ADDED - PASS (tick)
  • 8.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)FAIL (error)
    • Flow count looks wrong: 17
  • 8.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)FAIL (error)
    • Flow count looks wrong: 17
  • 8.16 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS (tick)FAIL (error)
    • Flow count looks wrong: 17
  • 8.17 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS (tick)FAIL (error)
    • Flow count looks wrong: 17
  • 8.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE8 - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 8.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE8 - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 8.20 Stopping Mininet - PASS (tick)
  • 8.21 Copying karaf logs - PASS (tick)

...

  • 76.1 Apply cell to environment - PASS (tick)
  • 76.2 Uninstalling Atomix - PASS (tick)
  • 76.3 Uninstalling ONOS package - PASS (tick)
  • 76.4 Installing Atomix - PASS (tick)
  • 76.5 Installing ONOS package - PASS (tick)
  • 76.6 Set up ONOS secure SSH - PASS (tick)
  • 76.7 Checking ONOS service - PASS (tick)
  • 76.8 Starting ONOS CLI sessions - PASS (tick)
  • 76.9 Checking ONOS nodes - PASS (tick)
  • 76.10 Checking ONOS applications - PASS (tick)
  • 76.11 Starting Mininet Topology - PASS (tick)
  • 76.12 Check whether the flow count is bigger than 74 - PASS (tick)
  • 76.13 Check whether all flow status are ADDED - PASS (tick)
  • 76.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 76.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 76.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE76 - PASS (tick)
  • 76.17 Stopping Mininet - PASS (tick)
  • 76.18 Copying karaf logs - PASS (tick)

Case 77: Bridging test between untagged and tagged hosts with different vlan id, with 2x2 leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 77.1 Apply cell to environment - PASS (tick)
  • 77.2 Uninstalling Atomix - PASS (tick)
  • 77.3 Uninstalling ONOS package - PASS (tick)
  • 77.4 Installing Atomix - PASS (tick)
  • 77.5 Installing ONOS package - PASS (tick)
  • 77.6 Set up ONOS secure SSH - PASS (tick)
  • 77.7 Checking ONOS service - PASS (tick)
  • 77.8 Starting ONOS CLI sessions - PASS (tick)
  • 77.9 Checking ONOS nodes - PASS (tick)
  • 77.10 Checking ONOS applications - PASS (tick)
  • 77.11 Starting Mininet Topology - PASS (tick)
  • 77.12 Check whether the flow count is bigger than 74 - PASS (tick)
  • 77.13 Check whether all flow status are ADDED - PASS (tick)
  • 77.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 77.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)FAIL (error)
    • Flow count looks wrong: 17
  • 77.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE77 - PASS (tick)
  • 77.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE77 - PASS (tick)
  • 77.18 Stopping Mininet - PASS (tick)
  • 77.19 Copying karaf logs - PASS (tick)

...