- 13.1 Constructing test variables - PASS
- 13.2 Apply cell to environment - PASS
- 13.3 Uninstalling Atomix - PASS
- 13.4 Uninstalling ONOS package - PASS
- 13.5 Creating ONOS package - PASS
- 13.6 Installing Atomix - PASS
- 13.7 Installing ONOS package - PASS
- 13.8 Set up ONOS secure SSH - PASS
- 13.9 Checking ONOS service - PASS
- 13.10 Starting ONOS CLI sessions - PASS
- 13.11 Checking ONOS nodes - PASS
- 13.12 Checking ONOS applications - PASS
- 13.13 Starting Mininet Topology - PASS
- 13.14 Check whether the flow count is bigger than 104 - PASS
- 13.15 Check whether all flow status are ADDED - PASS
- 13.16 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE13_Before - PASS
- 13.17 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 13.18 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 13.19 Check whether the flow count is bigger than 104 - PASS
- 13.20 Check whether all flow status are ADDED - PASS
- 13.21 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE13_After - PASS
- 13.22 Stopping Mininet - PASS
- 13.23 Copying karaf logs - PASS
Case 23: Changing port configuration from untagged 10 to tagged 20 and native 10, with 2x2 leaf-spine topology and 3 ONOS instances -
...
FAIL
- 23.1 Apply cell to environment - PASS
- 23.2 Uninstalling Atomix - PASS
- 23.3 Uninstalling ONOS package - PASS
- 23.4 Installing Atomix - PASS
- 23.5 Installing ONOS package - PASS
- 23.6 Set up ONOS secure SSH - PASS
- 23.7 Checking ONOS service - PASS
- 23.8 Starting ONOS CLI sessions - PASS
- 23.9 Checking ONOS nodes - PASS
- 23.10 Checking ONOS applications - PASS
- 23.11 Starting Mininet Topology - PASS
- 23.12 Check whether the flow count is bigger than 106 - PASS
- 23.13 Check whether all flow status are ADDED - PASS
- 23.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE23_Before - PASS
- 23.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE23_Before - PASS
- 23.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 23.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 23.18 Check whether the flow count is bigger than 106 - PASS
- 23.19 Check whether all flow status are ADDED - PASS FAIL
- Flow status is wrong!
- 23.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE23_After - PASS
- 23.21 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE23_After - PASS
- 23.22 Stopping Mininet - PASS
- 23.23 Copying karaf logs - PASS
...
- 53.1 Apply cell to environment - PASS
- 53.2 Uninstalling Atomix - PASS
- 53.3 Uninstalling ONOS package - PASS
- 53.4 Installing Atomix - PASS
- 53.5 Installing ONOS package - PASS
- 53.6 Set up ONOS secure SSH - PASS
- 53.7 Checking ONOS service - PASS
- 53.8 Starting ONOS CLI sessions - PASS
- 53.9 Checking ONOS nodes - PASS
- 53.10 Checking ONOS applications - PASS
- 53.11 Starting Mininet Topology - PASS
- 53.12 Check whether the flow count is bigger than 104 - PASS
- 53.13 Check whether all flow status are ADDED - PASS
- 53.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE53_Before - PASS
- 53.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE53_Before - PASS
- 53.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 53.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 53.18 Check whether the flow count is bigger than 104 - PASS
- 53.19 Check whether all flow status are ADDED - PASS
- 53.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE53_After - PASS
- 53.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE53_After - PASS
- 53.22 Stopping Mininet - PASS
- 53.23 Copying karaf logs - PASS
Case 63: Changing port configuration from untagged 10 to tagged 120 with native 110, with 2x2 leaf-spine topology and 3 ONOS instances -
...
FAIL
- 63.1 Apply cell to environment - PASS
- 63.2 Uninstalling Atomix - PASS
- 63.3 Uninstalling ONOS package - PASS
- 63.4 Installing Atomix - PASS
- 63.5 Installing ONOS package - PASS
- 63.6 Set up ONOS secure SSH - PASS
- 63.7 Checking ONOS service - PASS
- 63.8 Starting ONOS CLI sessions - PASS
- 63.9 Checking ONOS nodes - PASS
- 63.10 Checking ONOS applications - PASS
- 63.11 Starting Mininet Topology - PASS
- 63.12 Check whether the flow count is bigger than 104 - PASS
- 63.13 Check whether all flow status are ADDED - PASS
- 63.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE63_Before - PASS
- 63.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE63_Before - PASS
- 63.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 63.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 63.18 Check whether the flow count is bigger than 104 - PASS
- 63.19 Check whether all flow status are ADDED - PASS FAIL
- Flow status is wrong!
- 63.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE63_After - PASS
- 63.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE63_After - PASS
- 63.22 Stopping Mininet - PASS
- 63.23 Copying karaf logs - PASS
...
- 113.1 Apply cell to environment - PASS
- 113.2 Uninstalling Atomix - PASS
- 113.3 Uninstalling ONOS package - PASS
- 113.4 Installing Atomix - PASS
- 113.5 Installing ONOS package - PASS
- 113.6 Set up ONOS secure SSH - PASS
- 113.7 Checking ONOS service - PASS
- 113.8 Starting ONOS CLI sessions - PASS
- 113.9 Checking ONOS nodes - PASS
- 113.10 Checking ONOS applications - PASS
- 113.11 Starting Mininet Topology - PASS
- 113.12 Check whether the flow count is bigger than 104 - PASS
- 113.13 Check whether all flow status are ADDED - PASS
- 113.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE113_Before - PASS
- 113.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE113_Before - PASS
- 113.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 113.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 113.18 Check whether the flow count is bigger than 104 - PASS
- 113.19 Check whether all flow status are ADDED - PASS
- 113.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE113_After - PASS
- 113.21 Verify full connectivity for [u'h1', u'h2', u'h3'] with tag CASE113_After - PASS
- 113.22 Stopping Mininet - PASS
- 113.23 Copying karaf logs - PASS
Case 123: Changing port configuration from tagged 20 and native 10 to tagged 20 and native 110, with 2x2 leaf-spine topology and 3 ONOS instances -
...
FAIL
- 123.1 Apply cell to environment - PASS
- 123.2 Uninstalling Atomix - PASS
- 123.3 Uninstalling ONOS package - PASS
- 123.4 Installing Atomix - PASS
- 123.5 Installing ONOS package - PASS
- 123.6 Set up ONOS secure SSH - PASS
- 123.7 Checking ONOS service - PASS
- 123.8 Starting ONOS CLI sessions - PASS
- 123.9 Checking ONOS nodes - PASS
- 123.10 Checking ONOS applications - PASS
- 123.11 Starting Mininet Topology - PASS
- 123.12 Check whether the flow count is bigger than 104 - PASS
- 123.13 Check whether all flow status are ADDED - PASS
- 123.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE123_Before - PASS
- 123.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE123_Before - PASS
- 123.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 123.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 123.18 Check whether the flow count is bigger than 104 - PASS
- 123.19 Check whether all flow status are ADDED - PASS FAIL
- Flow status is wrong!
- 123.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE123_After - PASS
- 123.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE123_After - PASS
- 123.22 Stopping Mininet - PASS
- 123.23 Copying karaf logs - PASS
...
- 163.1 Apply cell to environment - PASS
- 163.2 Uninstalling Atomix - PASS
- 163.3 Uninstalling ONOS package - PASS
- 163.4 Installing Atomix - PASS
- 163.5 Installing ONOS package - PASS
- 163.6 Set up ONOS secure SSH - PASS
- 163.7 Checking ONOS service - PASS
- 163.8 Starting ONOS CLI sessions - PASS
- 163.9 Checking ONOS nodes - PASS
- 163.10 Checking ONOS applications - PASS
- 163.11 Starting Mininet Topology - PASS
- 163.12 Check whether the flow count is bigger than 106 - PASS
- 163.13 Check whether all flow status are ADDED - PASS
- 163.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE163_Before - PASS
- 163.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE163_Before - PASS
- 163.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 163.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 163.18 Check whether the flow count is bigger than 106 - PASS
- 163.19 Check whether all flow status are ADDED - PASS
- 163.20 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE163_After - PASS
- 163.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE163_After - PASS
- 163.22 Stopping Mininet - PASS
- 163.23 Copying karaf logs - PASS
Case 173: Changing port configuration from tagged 20 to tagged 120, with 2x2 leaf-spine topology and 3 ONOS instances -
...
FAIL
- 173.1 Apply cell to environment - PASS
- 173.2 Uninstalling Atomix - PASS
- 173.3 Uninstalling ONOS package - PASS
- 173.4 Installing Atomix - PASS
- 173.5 Installing ONOS package - PASS
- 173.6 Set up ONOS secure SSH - PASS
- 173.7 Checking ONOS service - PASS
- 173.8 Starting ONOS CLI sessions - PASS
- 173.9 Checking ONOS nodes - PASS
- 173.10 Checking ONOS applications - PASS
- 173.11 Starting Mininet Topology - PASS
- 173.12 Check whether the flow count is bigger than 106 - PASS
- 173.13 Check whether all flow status are ADDED - PASS
- 173.14 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE173_Before - PASS
- 173.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE173_Before - PASS
- 173.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 173.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 173.18 Check whether the flow count is bigger than 106 - PASS
- 173.19 Check whether all flow status are ADDED - PASS FAIL
- Flow status is wrong!
- 173.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE173_After - PASS
- 173.21 Verify full connectivity for [u'h1', u'h2', u'h3'] with tag CASE173_After - PASS
- 173.22 Stopping Mininet - PASS
- 173.23 Copying karaf logs - PASS
Case 183: Changing port configuration from tagged 20 to tagged 20 and native 10, with 2x2 leaf-spine topology and 3 ONOS instances -
...
PASS
- 183.1 Apply cell to environment - PASS
- 183.2 Uninstalling Atomix - PASS
- 183.3 Uninstalling ONOS package - PASS
- 183.4 Installing Atomix - PASS
- 183.5 Installing ONOS package - PASS
- 183.6 Set up ONOS secure SSH - PASS
- 183.7 Checking ONOS service - PASS
- 183.8 Starting ONOS CLI sessions - PASS
- 183.9 Checking ONOS nodes - PASS
- 183.10 Checking ONOS applications - PASS
- 183.11 Starting Mininet Topology - PASS
- 183.12 Check whether the flow count is bigger than 106 - PASS
- 183.13 Check whether all flow status are ADDED - PASS
- 183.14 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE183_Before - FAIL IP connectivity failed
- PASS
- 183.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE183_Before - PASS
- 183.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 183.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 183.18 Check whether the flow count is bigger than 106 - PASS
- 183.19 Check whether all flow status are ADDED - PASS
- 183.20 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE183_After - FAIL IP connectivity failed
- PASS
- 183.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE183_After - PASS
- 183.22 Stopping Mininet - PASS
- 183.23 Copying karaf logs - PASS
...